Skip to content
Search

Search the site

95 pages for “q=q%3Dcan%2Bone%2Bq%2Bq%2Bcan%2B2bapprofondimenti%2B2bq%2B2bq%2Bswimming%2Bpool”
No page contains all the words: results containing some of them.

Systems and controllers

Public and collective-use swimming pools › Which system for your swimming pool

The pool volume determines the controller; the desired management determines the chlorine measurement or the multi-parameter system. 1Pool volume Up to 150 m³WD controller with two integrated pumps Above 150 m³LD controller with pumps sized for the pool 2Manag …

Also in: The treatment circuit of a public swimming pool · Centurio POOL: all the pool parameters · pH and chlorine in a pool with many bathers

Probes

Redox electrodes

… the Redox potential (ORP), that is the disinfecting power of the water, in swimming pools, waterworks and industrial plants. Suitable for all types of water, including low-conductivity water. Range ± 1,000 mV (± 1,500 mV) Also for low-conductivity water BNC or …

Also in: High linearity · Installation

Probes

ETORB2 turbidity

… light scattered at 90° and the nephelometric principle, for drinking water, swimming pool water and process water. Scratch-resistant sapphire glass optical window and water-jet self-cleaning ensure accurate measurements over time. Range 0/40 – 0/400 – 0/4,000 …

Also in: Measuring principle and self-cleaning · Installation

Systems and controllers

Footbath › Where it is used

Public swimming pools and pools for collective use Type 1, 2 and 3 pools according to UNI 10637:2024 (Italian standard): automatic measurement and control of pH and free chlorine. Public swimming pools →

Also in: Installation examples

Pumps

Dosing pumps › Not sure which pump to choose? We can help

Not sure which pump to choose? We can help Finding the right dosing pump No need to know the series and model in advance: state how the pump must dose, the product, the flow rate and the back pressure, and the guide proposes the most suitable pump among all se …

Probes

pH electrodes

… pH in water with a pH between 0 and 14, including low-conductivity water: for swimming pools, drinking water, wastewater and industrial water. Range 0 – 14 pH Also for low-conductivity water BNC or SN6 connection In by-pass, in-line or immersion Details Reques …

Also in: Installation

Systems and controllers

Controllers › Controller range

Do you need a complete system? You can find it here. Redox measurement LDsRh Measurement of the Redox potential (ORP) for dosing hypochlorite or other disinfectants. ± 1,000 mV Details → Compare Chlorine and disinfectants LDsCL Measurement of free and total ch …

Insights

Water treatment technology › All insights

… Well water Analysis and disinfection Chlorine measurement Systems Insight → Swimming pools Private swimming pools pH and disinfectants Redox, cells and DPD Insight → Swimming pools · Regulations Pools for collective use UNI 10637:2024 Closed cell and DPD Insig …

Systems and controllers

MAX5

… pumps. Discontinued The MAX5 has been replaced by the Centurio PRO and, for swimming pools, by the Centurio POOL: up to 10 channels, touch screen, Ethernet, Wi-Fi and Modbus as standard. Centurio POOL Centurio PRO Details Request a quotation MAX5discontinued C …

Probes

ECL free chlorine

Open amperometric cells for measuring free chlorine, suitable for swimming pool water: they provide the measurement directly in mg/l. Versions for fresh water and seawater. Range 0 – 10 mg/l Organic and inorganic free chlorine Fresh water or seawater Flow stab …

Pumps

Self-venting pumps

… air bleed The V and VMS series with automatic air bleed pump head, for swimming pools and for residential, healthcare and industrial applications. The V and VMS Series → KA and KMSA Series with automatic air bleed The K and KMS series with automatic air bleed …

Systems and controllers

Centurio Tower › System remote control

The controllers can be remotely controlled bidirectionally (read and write) from the web portal, from PC, tablet and smartphone: viewing of measurements, modification of set points, dosing and alarms, receipt of alarms and download of logs. Alternatively, inte …

Also in: Touch screen

Systems and controllers

Fertigation › System remote control

The controllers can be remotely controlled bidirectionally (read and write) from the web portal, from PC, tablet and smartphone: viewing of measurements, modification of set points, dosing and alarms, receipt of alarms and download of logs. Alternatively, inte …

Also in: The requirements · Installation examples

Probes

SCL cells › Bromine

SBR Bromine Continuous measurement of bromine in swimming pools, spas and cooling towers.

Also in: Ozone

Pumps

Double diaphragm

… viscous liquids or liquids containing suspended solids. They are self-priming, can be installed above the liquid level, below it (flooded suction) or submerged, and are also suitable for use in explosive atmospheres. Up to 1,000 l/min Self-priming Can also run …

Also in: Installation types · Available versions · Operating principle

Systems and controllers

Volumetric dosing › Operation

… to a volume of water: the pumps dose a proportional quantity. 2 Two products One pump for the fertiliser and one for the acid, with independent settings. 3 No probes Suitable when the quality of the irrigation water is constant. 4 Alarms Level probes in the ta …

Also in: Basic components · Installation examples

Systems and controllers

Panel-mount controllers › JA

… chlorine dioxide and ozone. Two ON/OFF or proportional digital outputs, one proportional pump output, one 0-4/20 mA output and a Modbus port for the PLC network; measuring channel plus temperature channel. Compare

Also in: DIN Digital · Pumps and accessories

Accessories

Magnetic scale inhibitors › Effects of limescale

… Deposits thermally insulate heating elements and heat exchangers: just one millimetre of limescale reduces the efficiency of a heating or cooling system by 10 – 20%. 3 Bacteria and biofilm Limescale is an ideal substrate for the deposition and proliferation of …

Also in: Applications

Other pages

Legal notice and privacy › Cookie policy

… service; to do so, the browser sends its IP address to these services. Consent can be changed or withdrawn at any time via the Cookie preferences link, which is also available at the bottom of each page. Cookies can also be deleted or blocked in the browser se …

Pumps

R Series › Troubleshooting and error messages

The R Series pumps have no electronics: most faults can be traced back to the compressed air supply or to maintenance. Insight: the pump does not prime and does not dose → Compressed air R pumps require a constant air supply, preferably at 6 bar (± 10%), free …

Accessories

Tanks and bunds › Fitting out as a dosing station

The tanks can be supplied pre-assembled with: Level gauge Graduated, for visual reading of the quantity of product. Manhole and taps Threaded filling manhole and filling and drain taps. Suction lance With foot filter and level probe. Details → Mixer For dissol …

Accessories

Lances › Advantages of lances

… in any case: the tank remains sealed, with no risk of vapours escaping. It can be pre-installed on our tanks, on existing tanks and on jerrycans. 2 Injection into the centre of the flow The injection lance ensures contact between the product and the water and …

Insights

Chemical compatibility

… diaphragms, seals and tubing, so that the most suitable configuration can be chosen for the liquid to be dosed. 490 chemicals 12 materials Search by name or formula Details Request a quotation PVDF pump head

Other pages

Product comparison › No products selected

… the bottom of the page, from which the comparison opens. Up to four products can be compared, including products from different series. Dosing pumpsControllersSystemsTransfer pumps

Probes

Conductivity › Installation

The probe is installed in one of the Giemme probe holders: 1 In by-pass In a flow-through probe holder, installed in by-pass on the pipe. Probe holders → 2 In-line In a probe holder mounted directly on the pipe. Probe holders → 3 Immersion In an immersion prob …

Probes

Inductive conductivity › Installation

The probe is installed in one of the Giemme probe holders: 1 In by-pass In a flow-through probe holder, installed in by-pass on the pipe. Probe holders → 2 In-line In a probe holder mounted directly on the pipe. Probe holders → 3 Immersion In an immersion prob …

Probes

EOLUM dissolved oxygen › Installation

The probe is installed in one of the Giemme probe holders: 1 In by-pass In a flow-through probe holder, installed in by-pass on the pipe. Probe holders → 2 In-line In a probe holder mounted directly on the pipe. Probe holders → 3 Immersion In an immersion prob …

Probes

Temperature › Installation

The probe is installed in one of the Giemme probe holders: 1 In by-pass In a flow-through probe holder, installed in by-pass on the pipe. Probe holders → 2 In-line In a probe holder mounted directly on the pipe. Probe holders → 3 Immersion In an immersion prob …

Pumps

Compressed-air pumps

… or viscous liquids or liquids containing suspended solids: self-priming, they can be installed above the liquid level, below it (flooded suction) or submerged, and are supplied with compressed air at 8 bar. Double diaphragm pumps → Drum pumps with air motor Li …

Pumps

Pumps for low-viscosity liquids › Installation and priming

… and of a diameter suited to the product. Priming With viscous liquids, priming can be assisted with a 20 cc syringe applied to the purge valve. Above 8,000 cPs For more viscous products, up to 50,000 cPs, pumps for polymers are used. Pumps for polymers →

Pumps

Magnetic drive › Operating principle

… directly connected to the impeller: rotation is transmitted by two magnets, one on the motor shaft and the other integral with the impeller, never in contact with the liquid. 1 No seals The impeller is not mechanically connected to the shaft: no shaft seals ar …

Pumps

Pumps for polymers › Installation and priming

… of a diameter suited to the product. Priming With viscous products, priming can be assisted with a 20 cc syringe applied to the purge valve. Up to 8,000 cPs For less viscous products, pumps for low-viscosity liquids are used. Pumps for low-viscosity liquids →

Systems and controllers

TETRAMIX › Installation examples

… tanks on the floor. Pumps, controllers or components supplied by the customer can also be fitted, with custom dimensions, back panel and electrical panel. Dosing stations and skids →

Contact

Tell us about your plant

Call or write to us: a technician will reply with a tailored proposal of controllers, pumps, probes and accessories.

What do you need?
Please enter your name.
Please enter a valid email address.
Please enter your message.

Describe your plant: type, water volume or flow rate, parameters to be controlled.

You must accept the privacy notice to continue.