RAC
Compressed air dosing pump.
- Constant
- Pneumatic adjustment
Compressed air operated diaphragm dosing pumps, suitable for dosing in car wash installations. They require compressed air free of lubricant and condensate, between 6 and 8 bar.
Compressed air dosing pump.
Pump head: PP
Compressed air dosing pump with control solenoid valve.
Pump head: PP
Compressed air dosing pump with button for manual priming.
Pump head: PP
| Function | RAC | RACV | RACP |
|---|---|---|---|
| Dosing modes | |||
| Constant | ● | ● | ● |
| Pneumatic adjustment | ● | ● | ● |
| Functions | |||
| Control solenoid valve | – | ● | – |
| Priming button | – | – | ● |
| Versatile mounting | ● | ● | ● |
The pump doses at a constant injection frequency, proportional to the flow rate percentage set with the analogue selector (0 – 100%).
Models: RAC, RACV, RACP
The injection frequency is set as a percentage with the front knob, up to 120 injections per minute: each cycle lasts approximately 0.5 seconds, half with the pump supplied with air and half without supply.
Models: RAC, RACV, RACP
Suitable for most chemicals: the standard configuration for the most common applications.
| Code | Max pressure (bar) | Max flow rate (l/h) |
|---|---|---|
| RAC 0612 | 6 | 12 |
| RAC 0606 | 6 | 6 |
| RAC 0603 | 6 | 3 |
| RAC 0601 | 6 | 1 |
Suitable for sodium hydroxide (caustic soda).
The R Series pumps have no electronics: most faults can be traced back to the compressed air supply or to maintenance.
Insight: the pump does not prime and does not dose →R pumps require a constant air supply, preferably at 6 bar (± 10%), free of oil and condensate. The maximum frequency is 120 injections per minute (approximately 0.25 s of work and 0.25 s of return): the solenoid valve or PLC must be set accordingly.
Connect discharge, suction and drain, open the drain valve, set the knob to 100% and supply air; close the drain as soon as the chemical comes out. On the RACP the operation can be assisted with the manual priming button; with viscous chemicals use a 20 cc syringe applied to the drain.
At least once a month check the electrical and hydraulic connections, the condition of the diaphragm, the absence of leaks from tubes and fittings and any corroded parts.
If the problem persists, contact us. Before sending the pump for servicing, empty the pump head of chemical and dry it.
The pump is actuated by a PLC via a solenoid valve.
Models: RACV
A dedicated button allows the lines to be filled with the chemical to be dosed.
Models: RACP
Horizontal installation, on a DIN rail, or vertical installation by means of a dedicated bracket.
Tell us about your application: our technical staff will recommend the most suitable model, configuration and accessories.
Call or write to us: a technician will reply with a tailored proposal of controllers, pumps, probes and accessories.