Standard
ERhS, ERhM and ERhL: BNC connection and 0.8, 4.5 or 15 m cable.
Combination electrodes for measuring the Redox potential (ORP), that is the disinfecting power of the water, in swimming pools, waterworks and industrial plants. Suitable for all types of water, including low-conductivity water.
All models are combination electrodes and differ in cable, connection and application.
Insight: the Redox potential →ERhS, ERhM and ERhL: BNC connection and 0.8, 4.5 or 15 m cable.
ERhSN6: SN6 connection with PG13.5 thread, cable from 1 to 100 m, up to 100 °C.
ERhM/D; ERhMD/100 for temperatures up to 100 °C.
ERhSC (BNC) and ERhSC/SN6 (SN6), double junction.
ERhHLB SN6: high linearity and high sensitivity, designed to detect the low free chlorine concentrations of drinking water. Glass body, range ± 1,500 mV; it can be fitted with water-jet or air-jet self-cleaning.
| Electrode | Range | Pressure | Connection | Body | Minimum conductivity | Junction | Temperature | Cable | Diameter | Notes |
|---|---|---|---|---|---|---|---|---|---|---|
| ERhS | ± 1,000 mV | 7 bar (3.5 bar) | BNC | Epoxy | 100 µS | – | 70 °C (80 °C) | 0.8 m | 12 mm | – |
| ERhM | ± 1,000 mV | 7 bar (3.5 bar) | BNC | Epoxy | 100 µS | – | 70 °C (80 °C) | 4.5 m | 12 mm | – |
| ERhL | ± 1,000 mV | 7 bar (3.5 bar) | BNC | Epoxy | 100 µS | – | 70 °C (80 °C) | 15 m | 12 mm | – |
| ERhHLB SN6 | ± 1,500 mV | 6 bar | SN6 with PG13.5 thread | Glass | 100 µS | – | 80 °C | 10 m | 12 mm | High linearity and sensitivity, for low chlorine concentrations |
| ERhSN6 | ± 1,000 mV | 7 bar | SN6 with PG13.5 thread | Epoxy | 100 µS | – | 100 °C | 1 – 100 m | 12 mm | – |
| ERhMD/100 | ± 1,000 mV | 7 bar | BNC | Epoxy | 100 µS | Double | 100 °C | 4.5 m | 12 mm | – |
| ERhM/D | ± 1,000 mV | 7 bar (3.5 bar) | BNC | Epoxy | 100 µS | Double | 70 °C (80 °C) | 4.5 m | 12 mm | – |
| ERhSC | ± 1,000 mV | 7 bar (3.5 bar) | BNC | Epoxy | 100 µS | Double | 70 °C (80 °C) | 4.5 m | 12 mm | Self-cleaning |
| ERhSC/SN6 | ± 1,000 mV | 7 bar (3.5 bar) | SN6 with PG13.5 thread | Epoxy | 100 µS | Double | 70 °C (80 °C) | 1 – 100 m | 12 mm | Self-cleaning |
All models: combination electrode, resolution 1 mV.
The probe is installed in one of the Giemme probe holders:
In a flow-through probe holder, installed in by-pass on the pipe.
Probe holders →In a probe holder mounted directly on the pipe.
Probe holders →In an immersion probe holder, directly in the tank or basin.
Probe holders →Tell us the characteristics of the water to be measured and of the system: we will recommend the most suitable electrode, probe holder and controller.