Skip to content
Measuring electrodes

Redox electrodes

Combination electrodes for measuring the Redox potential (ORP), that is the disinfecting power of the water, in swimming pools, waterworks and industrial plants. Suitable for all types of water, including low-conductivity water.

  • Range ± 1,000 mV (± 1,500 mV)
  • Also for low-conductivity water
  • BNC or SN6 connection
  • In by-pass, in-line or immersion
Combination Redox (ORP) electrodes
Redox electrodes
ERhHLB SN6 high-linearity Redox electrode
ERhHLB SN6high linearity
± 1,500mVMaximum range
1mVResolution
100°CMaximum temperature
9Models
Models

Available models

All models are combination electrodes and differ in cable, connection and application.

Insight: the Redox potential →

Standard

ERhS, ERhM and ERhL: BNC connection and 0.8, 4.5 or 15 m cable.

SN6 connection

ERhSN6: SN6 connection with PG13.5 thread, cable from 1 to 100 m, up to 100 °C.

Double junction

ERhM/D; ERhMD/100 for temperatures up to 100 °C.

Self-cleaning

ERhSC (BNC) and ERhSC/SN6 (SN6), double junction.

High linearity

ERhHLB SN6: high linearity and high sensitivity, designed to detect the low free chlorine concentrations of drinking water. Glass body, range ± 1,500 mV; it can be fitted with water-jet or air-jet self-cleaning.

Technical data

Data sheet

ElectrodeRangePressureConnectionBodyMinimum conductivityJunctionTemperatureCableDiameterNotes
ERhS± 1,000 mV7 bar (3.5 bar)BNCEpoxy100 µS–70 °C (80 °C)0.8 m12 mm–
ERhM± 1,000 mV7 bar (3.5 bar)BNCEpoxy100 µS–70 °C (80 °C)4.5 m12 mm–
ERhL± 1,000 mV7 bar (3.5 bar)BNCEpoxy100 µS–70 °C (80 °C)15 m12 mm–
ERhHLB SN6± 1,500 mV6 barSN6 with PG13.5 threadGlass100 µS–80 °C10 m12 mmHigh linearity and sensitivity, for low chlorine concentrations
ERhSN6± 1,000 mV7 barSN6 with PG13.5 threadEpoxy100 µS–100 °C1 – 100 m12 mm–
ERhMD/100± 1,000 mV7 barBNCEpoxy100 µSDouble100 °C4.5 m12 mm–
ERhM/D± 1,000 mV7 bar (3.5 bar)BNCEpoxy100 µSDouble70 °C (80 °C)4.5 m12 mm–
ERhSC± 1,000 mV7 bar (3.5 bar)BNCEpoxy100 µSDouble70 °C (80 °C)4.5 m12 mmSelf-cleaning
ERhSC/SN6± 1,000 mV7 bar (3.5 bar)SN6 with PG13.5 threadEpoxy100 µSDouble70 °C (80 °C)1 – 100 m12 mmSelf-cleaning

All models: combination electrode, resolution 1 mV.

Installation

Installation

The probe is installed in one of the Giemme probe holders:

1

In by-pass

In a flow-through probe holder, installed in by-pass on the pipe.

Probe holders →
3

Immersion

In an immersion probe holder, directly in the tank or basin.

Probe holders →

Advice on selection

Tell us the characteristics of the water to be measured and of the system: we will recommend the most suitable electrode, probe holder and controller.

Contact

Tell us about your plant

Call or write to us: a technician will reply with a tailored proposal of controllers, pumps, probes and accessories.

What do you need?
Please enter your name.
Please enter a valid email address.
Please enter your message.

Describe your plant: type, water volume or flow rate, parameters to be controlled.

You must accept the privacy notice to continue.