Skip to content
Measuring electrodes

pH electrodes

Combination electrodes for measuring pH in water with a pH between 0 and 14, including low-conductivity water: for swimming pools, drinking water, wastewater and industrial water.

  • Range 0 – 14 pH
  • Also for low-conductivity water
  • BNC or SN6 connection
  • In by-pass, in-line or immersion
Combination pH electrodes
pH electrodes13 models
0 – 14pHMeasuring range
0.01Resolution
135°CMaximum temperature
13Models
Models

Available models

All models are combination electrodes with an epoxy body (glass for the high-temperature model). They differ in cable, connection and application.

Insight: how pH is measured →

Standard

EPHS, EPHM and EPHL: BNC connection and 0.8, 4.5 or 15 m cable.

SN6 connection

EPHSN6: SN6 connection with PG13.5 thread and cable from 1 to 100 m.

Double junction

EPHM/D (BNC) and EPHM/D/SN6 (SN6); EPHMD/100 for temperatures up to 100 °C.

Low conductivity

EPHMD/LI: for water with a minimum conductivity of 3 µS.

Self-cleaning

EPHSC (BNC) and EPHSC/SN6 (SN6), double junction.

Hydrofluoric acid

EPHM/HF: resistant to 1% hydrofluoric acid.

High temperature

EPHSN6 GK: glass body, from −5 to 135 °C and up to 10 bar.

Technical data

Data sheet

ElectrodePressureConnectionBodyMinimum conductivityJunctionTemperatureCableDiameterNotes
EPHS7 bar (3.5 bar)BNCEpoxy100 µS–70 °C (80 °C)0.8 m12 mm–
EPHM7 bar (3.5 bar)BNCEpoxy100 µS–70 °C (80 °C)4.5 m12 mm–
EPHL7 bar (3.5 bar)BNCEpoxy100 µS–70 °C (80 °C)15 m12 mm–
EPHSN67 bar (3.5 bar)SN6 with PG13.5 threadEpoxy100 µS–70 °C (80 °C)1 – 100 m12 mm–
EPHMD/1007 barBNCEpoxy100 µSDouble100 °C4.5 m12 mm–
EPHM/D7 bar (3.5 bar)BNCEpoxy100 µSDouble70 °C (80 °C)4.5 m12 mm–
EPHM/D/SN67 bar (3.5 bar)SN6 with PG13.5 threadEpoxy100 µSDouble70 °C (80 °C)1 – 100 m12 mm–
EPHMD/LI7 bar (3.5 bar)SN6 with PG13.5 threadEpoxy3 µSDouble70 °C (80 °C)1 – 100 m12 mmFor low-conductivity water
EPHSC7 bar (3.5 bar)BNCEpoxy100 µSDouble70 °C (80 °C)4.5 m12 mmSelf-cleaning
EPHSC/SN67 bar (3.5 bar)SN6 with PG13.5 threadEpoxy100 µSDouble70 °C (80 °C)1 – 100 m12 mmSelf-cleaning
EPHM/HF7 bar (3.5 bar)BNCEpoxy100 µSDouble70 °C (80 °C)4.5 m12 mmResistant to 1% hydrofluoric acid
EPHSN6 GK10 barSN6Glass150 µS–−5 / 135 °C1 – 100 m12 mmHigh temperature

All models: combination electrode, range 0 – 14 pH, resolution 0.01.

Installation

Installation

The probe is installed in one of the Giemme probe holders:

1

In by-pass

In a flow-through probe holder, installed in by-pass on the pipe.

Probe holders →
3

Immersion

In an immersion probe holder, directly in the tank or basin.

Probe holders →

Advice on selection

Tell us the characteristics of the water to be measured and of the system: we will recommend the most suitable electrode, probe holder and controller.

Contact

Tell us about your plant

Call or write to us: a technician will reply with a tailored proposal of controllers, pumps, probes and accessories.

What do you need?
Please enter your name.
Please enter a valid email address.
Please enter your message.

Describe your plant: type, water volume or flow rate, parameters to be controlled.

You must accept the privacy notice to continue.