Systems and controllers

Legionella control › Which system for your installation

… product YesBiocide and polyphosphate, two pumps NoBiocide only, one pump 5Installation On a panelWith flow sensor, multifunction valve and static mixer Dosing stationPump installed on the tank Answer the questions: the recommended system appears below. Recomme …

Also in: Type 4 – Volumetric with one dosing pump · Typical layouts · Stabilised versus generated in situ · Type 1 – Volumetric and residual control

Systems and controllers

Public and collective-use swimming pools › Remote control

Controllers and pumps can be remotely monitored and controlled via Wi-Fi, Ethernet or 4G from the web portal, free of charge and with no subscription: set points, dosing and alarms can be changed, alarm notifications received and logged data downloaded, which …

Also in: Which system for your swimming pool · Installation examples · The treatment circuit of a public swimming pool · pH and chlorine in a pool with many bathers

Accessories

Magnetic scale inhibitors › Applications

It can easily be installed on any system, upstream of each point of use, as required. Water supply networks Downstream of the storage reservoirs of large public water supply networks, on the pipes distributing water to users. Homes Downstream of the water mete …

Also in: Effects of limescale

Other pages

Product comparison › No products selected

… the bottom of the page, from which the comparison opens. Up to four products can be compared, including products from different series. Dosing pumpsControllersSystemsTransfer pumps

Pumps

Dosing pumps › Not sure which pump to choose? We can help

Not sure which pump to choose? We can help Finding the right dosing pump No need to know the series and model in advance: state how the pump must dose, the product, the flow rate and the back pressure, and the guide proposes the most suitable pump among all se …

Systems and controllers

TETRAMIX › System components

Feed screw PPH powder feeder with coated screw, driven by a brushless motor controlled from the HMI; 35-litre hopper with vibrator (expandable on request), radar minimum powder level; concentration adjustable from 0.05 to 0.5%. Preparation water Ultrasonic flo …

Also in: Installation examples

Energy

Hydroelectric mini-turbines › Energy from the pressure in the main

… the limits of the energy produced; an LED indicates the state of charge of the system. Depending on the combination of flow rate and back pressure in the main, even outside the values in the table, the turbine is adapted (nozzle, runner, solenoid valve) to pro …

Systems and controllers

Chlorine dioxide › Installation examples

Systems are supplied pre-assembled and tested, in the form best suited to the plant room: on a panel, in a cabinet or on a skid (with cover, in a box or on a frame), also tailor-made. Some examples. On a panel Controller, pumps, probe holder and accessories mo …

Also in: Drinking water · Basic components

Systems and controllers

Footbath › Installation examples

Systems are supplied pre-assembled and tested, in the form best suited to the plant room: on a panel, in a cabinet or on a skid (with cover, in a box or on a frame), also tailor-made. Some examples. On a panel Controller, pumps, probe holder and accessories mo …

Systems and controllers

Controllers › Controller range

Do you need a complete system? You can find it here. Redox measurement LDsRh Measurement of the Redox potential (ORP) for dosing hypochlorite or other disinfectants. ± 1,000 mV Details → Compare Chlorine and disinfectants LDsCL Measurement of free and total ch …

Probes

Inductive conductivity › Data sheet

… Measuring range 0.3 – 3 mS 0.3 – 30 mS 0.3 – 300 mS 0.3 – 10 mS Measuring system Inductive Inductive Body PEEK PEEK Mounting In-line / by-pass / immersion In-line / by-pass / immersion Temperature compensation PT100 PT100 Operating temperature 1 – 85 °C (100 ° …

Also in: Installation

Probes

EOLUM dissolved oxygen › Data sheet

EOLUM Measuring range 0 – 20 mg/l Resolution 0.01 Measuring system Fluorescence Automatic compensation Temperature and pressure Operating temperature −5 / +50 °C Operating pressure 10 bar Body Stainless steel

Also in: Installation

Systems and controllers

MAX5

The MAX5 multiparameter system is no longer in production: it has been replaced by Centurio PRO and, for swimming pools, by Centurio POOL, with more channels, a touch screen and remote control as standard.

Accessories

Accessories › Accessory range

… 1/2" – 4" No power supply Details → Tell us the characteristics of your system: we will propose the accessories best suited to the pump and probes in use. Contact us Dosing pumps Electrodes and probes

Probes

ETRC2 tracers

Fluorometer for industrial water systems that require continuous monitoring of tracers (fluorescent dyes): it combines reliability and high performance with minimal maintenance. Range 0 – 300 ppb Sensitivity 1 ppb Response in 5 seconds In-line installation wit …

Insights

Water treatment technology › All insights

… → Drinking water Well water Analysis and disinfection Chlorine measurement Systems Insight → Swimming pools Private swimming pools pH and disinfectants Redox, cells and DPD Insight → Swimming pools · Regulations Pools for collective use UNI 10637:2024 Closed c …

Pumps

R Series › Troubleshooting and error messages

The R Series pumps have no electronics: most faults can be traced back to the compressed air supply or to maintenance. Insight: the pump does not prime and does not dose → Compressed air R pumps require a constant air supply, preferably at 6 bar (± 10%), free …

Probes

SCL cells › Self-cleaning cells for hot water

For Legionella control systems and cooling towers, SCL18 (free chlorine) and SCL17 (chlorine dioxide) are available. Legionella: risks, regulations and treatments → Three electrodes, no membrane The cell has no semi-permeable membrane and features three measur …

Also in: Data sheet

Accessories

Tanks and bunds › Fitting out as a dosing station

The tanks can be supplied pre-assembled with: Level gauge Graduated, for visual reading of the quantity of product. Manhole and taps Threaded filling manhole and filling and drain taps. Suction lance With foot filter and level probe. Details → Mixer For dissol …

Accessories

Lances › Advantages of lances

… in any case: the tank remains sealed, with no risk of vapours escaping. It can be pre-installed on our tanks, on existing tanks and on jerrycans. 2 Injection into the centre of the flow The injection lance ensures contact between the product and the water and …

Insights

Chemical compatibility

… diaphragms, seals and tubing, so that the most suitable configuration can be chosen for the liquid to be dosed. 490 chemicals 12 materials Search by name or formula Details Request a quotation PVDF pump head

Probes

Conductivity › Installation

The probe is installed in one of the Giemme probe holders: 1 In by-pass In a flow-through probe holder, installed in by-pass on the pipe. Probe holders → 2 In-line In a probe holder mounted directly on the pipe. Probe holders → 3 Immersion In an immersion prob …

Probes

ECL free chlorine › Data sheet

… Redox (PG13.5) Temperature, pH, Redox Temperature – – All models: amperometric system, range 0 – 10 mg/l, resolution 0.01, organic and inorganic free chlorine, operating temperature 1 – 40 °C, pressure 0.4 – 5 bar, water flow 40 l/h.

Probes

pH electrodes › Installation

The probe is installed in one of the Giemme probe holders: 1 In by-pass In a flow-through probe holder, installed in by-pass on the pipe. Probe holders → 2 In-line In a probe holder mounted directly on the pipe. Probe holders → 3 Immersion In an immersion prob …

Probes

Temperature › Installation

The probe is installed in one of the Giemme probe holders: 1 In by-pass In a flow-through probe holder, installed in by-pass on the pipe. Probe holders → 2 In-line In a probe holder mounted directly on the pipe. Probe holders → 3 Immersion In an immersion prob …

Pumps

Compressed-air pumps

… or viscous liquids or liquids containing suspended solids: self-priming, they can be installed above the liquid level, below it (flooded suction) or submerged, and are supplied with compressed air at 8 bar. Double diaphragm pumps → Drum pumps with air motor Li …

Pumps

Pumps for low-viscosity liquids › Installation and priming

… and of a diameter suited to the product. Priming With viscous liquids, priming can be assisted with a 20 cc syringe applied to the purge valve. Above 8,000 cPs For more viscous products, up to 50,000 cPs, pumps for polymers are used. Pumps for polymers →

Pumps

Magnetic drive › Operating principle

… directly connected to the impeller: rotation is transmitted by two magnets, one on the motor shaft and the other integral with the impeller, never in contact with the liquid. 1 No seals The impeller is not mechanically connected to the shaft: no shaft seals ar …

Pumps

Pumps for polymers › Installation and priming

… of a diameter suited to the product. Priming With viscous products, priming can be assisted with a 20 cc syringe applied to the purge valve. Up to 8,000 cPs For less viscous products, pumps for low-viscosity liquids are used. Pumps for low-viscosity liquids →

Accessories

Probe holders

… be measured into contact with the electrodes. Depending on the probe and the system, the electrode is installed in by-pass, in-line or by immersion. Flow-through, in by-pass In-line, on the pipe Immersion, in the tank Manifold for cooling towers Available mode …

Contact

Tell us about your plant

Call or write to us: a technician will reply with a tailored proposal of controllers, pumps, probes and accessories.

What do you need?
Please enter your name.
Please enter a valid email address.
Please enter your message.

Describe your plant: type, water volume or flow rate, parameters to be controlled.

You must accept the privacy notice to continue.