Fluorometer for industrial water systems that require continuous monitoring of tracers (fluorescent dyes): it combines reliability and high performance with minimal maintenance.

  • Range 0 – 300 ppb
  • Sensitivity 1 ppb
  • Response in 5 seconds
  • In-line installation with T-fitting
ETRC2 fluorometer for tracers with T-fitting
With T-fitting
ETRC2 fluorometer for tracers
ETRC2
Optical window of the ETRC2 fluorometer
Optical window
0 – 300ppbMeasuring range
1ppbSensitivity
5sResponse time
7barOperating pressure
Technical data

Data sheet

ETRC2
Measuring range0 – 300 ppb of PTSA
Error± 1 ppb or 5% of reading
Sensitivity1 ppb
Linearity0.99 r²
Signal sourceLED
DetectionPhotodiode
Response time5 seconds
Sample pressure100 psi (approx. 7 bar)
Sample temperature4 – 40 °C
Ambient temperature4 – 49 °C
Output4-20 mA and RS-485 Modbus RTU
Power supply24 VDC (± 2 V), 65 mA
BodyPVC
Installation

Installation

The probe must be in contact with the water to be analysed: