Skip to content
Search

Search the site

89 pages for “q=can+alarm+q+q+can+2bapprofondimenti+2bq+2bq+legionella”
No page contains all the words: results containing some of them.

Systems and controllers

Private swimming pools › Remote control

The controllers can be remotely monitored and controlled via Wi-Fi, Ethernet or 4G from the web portal, free of charge and with no subscription: set points, dosing, alarms and logged data are accessible from PC, tablet and smartphone. Wi-Fi Wireless connection …

Also in: Technical data · Installation examples

Systems and controllers

Fertigation › System remote control

The controllers can be remotely controlled bidirectionally (read and write) from the web portal, from PC, tablet and smartphone: viewing of measurements, modification of set points, dosing and alarms, receipt of alarms and download of logs. Alternatively, inte …

Also in: The requirements · Installation examples

Systems and controllers

TETRAMIX › System components

… and 4-blade 400 mm propeller: precise speed control and reduced consumption. Alarms: emergency stop, low water flow, minimum solution level, maximum level (H), overflow (HH).

Also in: Installation examples

Systems and controllers

Controllers

… from single-parameter to multiparameter: they drive dosing pumps, valves and alarms, including via remote control. The WD, WN and WT controllers have integrated dosing pumps. Chlorine and disinfectants pH and Redox Conductivity, turbidity, oxygen Remote contro …

Also in: Controller range

Insights

Water treatment technology › All insights

… pool discharge D.Lgs. 152/2006 Dechlorination Insight → Drinking water · Legionella Chlorine dioxide Stabilised or generated on site Production and dosing Insight → Cooling towers · Legionella Cooling towers Cycles of concentration Technical terms 2015 Guideli …

Pumps

Dosing pumps › Not sure which pump to choose? We can help

Not sure which pump to choose? We can help Finding the right dosing pump No need to know the series and model in advance: state how the pump must dose, the product, the flow rate and the back pressure, and the guide proposes the most suitable pump among all se …

Pumps

Double diaphragm

… viscous liquids or liquids containing suspended solids. They are self-priming, can be installed above the liquid level, below it (flooded suction) or submerged, and are also suitable for use in explosive atmospheres. Up to 1,000 l/min Self-priming Can also run …

Also in: Installation types · Available versions

Other pages

Legal notice and privacy › Cookie policy

… service; to do so, the browser sends its IP address to these services. Consent can be changed or withdrawn at any time via the Cookie preferences link, which is also available at the bottom of each page. Cookies can also be deleted or blocked in the browser se …

Pumps

R Series › Troubleshooting and error messages

The R Series pumps have no electronics: most faults can be traced back to the compressed air supply or to maintenance. Insight: the pump does not prime and does not dose → Compressed air R pumps require a constant air supply, preferably at 6 bar (± 10%), free …

Accessories

Magnetic scale inhibitors › Applications

It can easily be installed on any system, upstream of each point of use, as required. Water supply networks Downstream of the storage reservoirs of large public water supply networks, on the pipes distributing water to users. Homes Downstream of the water mete …

Accessories

Tanks and bunds › Fitting out as a dosing station

The tanks can be supplied pre-assembled with: Level gauge Graduated, for visual reading of the quantity of product. Manhole and taps Threaded filling manhole and filling and drain taps. Suction lance With foot filter and level probe. Details → Mixer For dissol …

Accessories

Lances › Advantages of lances

… in any case: the tank remains sealed, with no risk of vapours escaping. It can be pre-installed on our tanks, on existing tanks and on jerrycans. 2 Injection into the centre of the flow The injection lance ensures contact between the product and the water and …

Accessories

Valves › Relief valve

… is ensured by preformed rings. It requires little maintenance and can also be used with dense fluids and, within certain limits, with substances containing solids.

Insights

Chemical compatibility

… diaphragms, seals and tubing, so that the most suitable configuration can be chosen for the liquid to be dosed. 490 chemicals 12 materials Search by name or formula Details Request a quotation PVDF pump head

Insights

Water pH control › Measurement problems

… chosen according to the actual operating conditions: several external factors can alter the measurement. Dirty diaphragm Deposits on the porous diaphragm generate spurious potentials and therefore measurement errors. Depending on the application, self-cleaning …

Other pages

Product comparison › No products selected

… the bottom of the page, from which the comparison opens. Up to four products can be compared, including products from different series. Dosing pumpsControllersSystemsTransfer pumps

Probes

Redox electrodes › High linearity

… chlorine concentrations of drinking water. Glass body, range ± 1,500 mV; it can be fitted with water-jet or air-jet self-cleaning.

Probes

ETORB2 turbidity › Measuring principle and self-cleaning

… nephelometric principle, with automatic temperature compensation. The range can be set to 0/40, 0/400 or 0/4,000 NTU. 2 Self-cleaning A water jet (maximum 1 bar), controlled by the controller according to the set programme, cleans the optical measuring window.

Pumps

Compressed-air pumps

… or viscous liquids or liquids containing suspended solids: self-priming, they can be installed above the liquid level, below it (flooded suction) or submerged, and are supplied with compressed air at 8 bar. Double diaphragm pumps → Drum pumps with air motor Li …

Pumps

F Series › Main features

… with a low-level probe for the tank: when the chemical runs out, it shows the alarm on the display and activates the corresponding output. Models: FCL Tell us about your application: our technical staff will recommend the most suitable model, configuration and …

Pumps

Pumps for low-viscosity liquids › Installation and priming

… and of a diameter suited to the product. Priming With viscous liquids, priming can be assisted with a 20 cc syringe applied to the purge valve. Above 8,000 cPs For more viscous products, up to 50,000 cPs, pumps for polymers are used. Pumps for polymers →

Pumps

Pumps for polymers › Installation and priming

… of a diameter suited to the product. Priming With viscous products, priming can be assisted with a 20 cc syringe applied to the purge valve. Up to 8,000 cPs For less viscous products, pumps for low-viscosity liquids are used. Pumps for low-viscosity liquids →

Systems and controllers

Footbath › Installation examples

… tanks on the floor. Pumps, controllers or components supplied by the customer can also be fitted, with custom dimensions, back panel and electrical panel. Dosing stations and skids →

Contact

Tell us about your plant

Call or write to us: a technician will reply with a tailored proposal of controllers, pumps, probes and accessories.

What do you need?
Please enter your name.
Please enter a valid email address.
Please enter your message.

Describe your plant: type, water volume or flow rate, parameters to be controlled.

You must accept the privacy notice to continue.