Skip to content
Search

Search the site

90 pages for “q=dosing+pump”

Systems and controllers

Legionella control › Type 3 – Volumetric with two dosing pumps

Compare Panel with two dosing pumps Combined dosing of biocide and protective food-grade polyphosphate, in proportion to the quantity of make-up water measured by the pulse-output water meter. Advantages Immediate disinfection of the incoming water, in proport …

Also in: Type 4 – Volumetric with one dosing pump · Type 5 – Volumetric dosing station · Which system for your installation · Type 1 – Volumetric and residual control

Accessories

SEFL flow sensor › Operating principle

… When the liquid passes through it, the sensor sends a pulse to the dosing pump, which records that dosing has taken place. 2 Recovery of missed strokes If the sensor does not detect the flow, for example because of an air bubble, the pump automatically re-prim …

Also in: Installation points · Materials

Pumps

R Series › Main features

Control solenoid valve The pump is actuated by a PLC via a solenoid valve. Models: RACV Priming button A dedicated button allows the lines to be filled with the chemical to be dosed. Models: RACP Versatile mounting Horizontal installation, on a DIN rail, or ve …

Also in: RAC · RACV · RACP

Systems and controllers

Permanganate › Preparation and dosing in a single supply

The PermaDos can be integrated with a dosing skid that draws the solution from the storage tank and injects it into the line to be treated. The skid is sized according to the plant flow rate and the required dose and is managed directly from the PermaDos contr …

Also in: PDS: accurate, proportional dosing · Components of the PermaDos unit · Installation examples · PermaDos: continuous preparation in four stages

Pumps

Transfer pumps › Available types

… → Compare Magnetic drive Up to 35 m³/h Up to 2.4 bar Details → Compare Drum pumps Details → Compare Tell us about your application: our technical staff will identify the pump best suited to your needs. Contact us Dosing pumps

Accessories

SOIM pulsation dampener

Pulsation dampeners stabilise the dosing of the chemical injected into the circuit by a dosing pump. They are diaphragm-free and available in various capacities and materials. Diaphragm-free PP or PVDF internal lining Various capacities Details Request a quota …

Also in: Materials

Accessories

Accessories › Accessory range

… of your system: we will propose the accessories best suited to the pump and probes in use. Contact us Dosing pumps Electrodes and probes

Accessories

Tanks and bunds › Fitting out as a dosing station

… level probe. Details → Mixer For dissolving and mixing the products. Details → Dosing pump Installed on the tank. Details → Safety bund To contain the product in the event of leaks. Details →

Systems and controllers

Controllers › Controller range

… it here. Redox measurement LDsRh Measurement of the Redox potential (ORP) for dosing hypochlorite or other disinfectants. ± 1,000 mV Details → Compare Chlorine and disinfectants LDsCL Measurement of free and total chlorine, chlorine dioxide, bromine, peroxide, …

Insights

Chemical compatibility

Dosing pumps are used to dose chemicals: for each chemical, the table shows the resistance of the materials of pump heads, valves, fittings, diaphragms, seals and tubing, so that the most suitable configuration can be chosen for the liquid to be dosed. 490 che …

Also in: Materials and their use

Accessories

Pulse-output water meters

Water meters that send pulses to the dosing pump according to the litres of water measured, allowing the chemical to be dosed in proportion to the water treated. Turbine or Woltmann type, for cold and hot water. From 1/2" to 12" Cold and hot water Wet or dry d …

Accessories

Lances › LASP suction lance

Suction LASP suction lance Allows the dosing pump to draw the product from the tank. Rigid PVC or PVDF tube with foot filter and level probe; at the top the suction hose connection, in the middle the tank fixing and the bleed hose connection.

Insights

Water treatment technology › All insights

… Pools for collective use UNI 10637:2024 Closed cell and DPD Insight → Dosing pumps The pump does not prime or dose Causes and remedies Priming Insight → Swimming pools · Regulations Swimming pool discharge D.Lgs. 152/2006 Dechlorination Insight → Drinking wate …

Systems and controllers

MAX5

… the measurement and control of 5 parameters and the management of up to 12 dosing pumps. Discontinued The MAX5 has been replaced by the Centurio PRO and, for swimming pools, by the Centurio POOL: up to 10 channels, touch screen, Ethernet, Wi-Fi and Modbus as s …

Also in: MAX5 functions

Contact

Tell us about your plant

Call or write to us: a technician will reply with a tailored proposal of controllers, pumps, probes and accessories.

What do you need?
Please enter your name.
Please enter a valid email address.
Please enter your message.

Describe your plant: type, water volume or flow rate, parameters to be controlled.

You must accept the privacy notice to continue.