Skip to content
Search

Search the site

79 pages for “cat=sistemi&q=q%3Dchlorine”

Systems and controllers

Public and collective-use swimming pools › pH and chlorine in a pool with many bathers

In water, hypochlorite splits into hypochlorous acid and hypochlorite ion, in proportions that depend on the pH: this is why the standard requires automatic control of both and the systems give priority to pH control. Insight: controlling the pH →Insight: chlo …

Also in: Free chlorine with closed cell · Free chlorine with ECL6 open cell · Closed (membrane) amperometric cells – Free chlorine · Which system for your swimming pool

Systems and controllers

Private swimming pools › Free chlorine with closed cell

… dosing pumps, selected according to the pool volume; it also manages the salt chlorinator and flocculant dosing. LDpHCl controller → Compare WNpHCl with closed cell Quiet version: two stepper-motor peristaltic pumps, quiet and precise; free chlorine with the S …

Also in: Free chlorine with ECL6 open cell · Alternatives to chlorine · Salt chlorinator management · Closed (membrane) amperometric cells – Free chlorine

Systems and controllers

LD Dual Parameter › Closed (membrane) amperometric cells – Free chlorine

Closed (membrane) amperometric cells – Free chlorine SCL3N/0.5 SCL3N/2 SCL3N/20 SCL18/0.5 SCL18/2 SCL18/20 SCL3S/20 Measuring range 0 – 0.5 mg/l 0 – 2 mg/l 0 – 20 mg/l 0 – 0.5 mg/l 0 – 2 mg/l 0 – 20 mg/l 0 – 20 mg/l Resolution 0.001 0.001 0.01 0.001 0.001 0.01 …

Also in: Closed (membrane) amperometric cells – Chlorine dioxide · Two parameters of your choice · LDpHCL · LDRhCL

Systems and controllers

Centurio POOL › How combined chlorine is measured

Combined chlorine, formed by chloramines, cannot be measured directly: the Centurio POOL derives it continuously from two amperometric measurements, as a subtraction. Insight: chlorine and combined chlorine → 1 Total chlorine A closed (membrane) amperometric c …

Also in: Closed (membrane) amperometric cells – Free chlorine · Basic components · Complete management of the swimming pool · The treatment circuit of a swimming pool

Systems and controllers

Centurio PRO › Closed (membrane) amperometric cells – Free chlorine

Closed (membrane) amperometric cells – Free chlorine SCL3N/0.5 SCL3N/2 SCL3N/20 SCL18/0.5 SCL18/2 SCL18/20 SCL3S/20 Measuring range 0 – 0.5 mg/l 0 – 2 mg/l 0 – 20 mg/l 0 – 0.5 mg/l 0 – 2 mg/l 0 – 20 mg/l 0 – 20 mg/l Resolution 0.001 0.001 0.01 0.001 0.001 0.01 …

Also in: Closed (membrane) amperometric cells – Chlorine dioxide · Water supply network · Application example: drinking water · Wastewater treatment

Systems and controllers

Controllers › Controller range

… Redox measurement LDsRh Measurement of the Redox potential (ORP) for dosing hypochlorite or other disinfectants. ± 1,000 mV Details → Compare Chlorine and disinfectants LDsCL Measurement of free and total chlorine, chlorine dioxide, bromine, peroxide, peraceti …

Systems and controllers

Centurio Tower › Closed (membrane) amperometric cells – Free chlorine

Closed (membrane) amperometric cells – Free chlorine SCL3N/0.5 SCL3N/2 SCL3N/20 SCL18/0.5 SCL18/2 SCL18/20 SCL3S/20 Measuring range 0 – 0.5 mg/l 0 – 2 mg/l 0 – 20 mg/l 0 – 0.5 mg/l 0 – 2 mg/l 0 – 20 mg/l 0 – 20 mg/l Resolution 0.001 0.001 0.01 0.001 0.001 0.01 …

Also in: Closed (membrane) amperometric cells – Chlorine dioxide · What the controller manages · Measuring channels · Closed (membrane) amperometric cells – Other oxidants

Systems and controllers

Cooling tower systems › Closed (membrane) amperometric cells – Free chlorine

Closed (membrane) amperometric cells – Free chlorine SCL3N/0.5 SCL3N/2 SCL3N/20 SCL18/0.5 SCL18/2 SCL18/20 SCL3S/20 Measuring range 0 – 0.5 mg/l 0 – 2 mg/l 0 – 20 mg/l 0 – 0.5 mg/l 0 – 2 mg/l 0 – 20 mg/l 0 – 20 mg/l Resolution 0.001 0.001 0.01 0.001 0.001 0.01 …

Also in: Closed (membrane) amperometric cells – Chlorine dioxide · Panel-mounted MTOWER · Which system for your tower · Measuring probes

Systems and controllers

Fire-fighting water tanks › WDpHCl

pH and free chlorine WDpHCl The WDpHCl controller measures pH and free chlorine and controls two integrated dosing pumps, one for the acid and one for the hypochlorite: a compact solution for keeping the water in the fire-fighting tank disinfected. Advantages …

Also in: LDsCL · WDpHRh · LDpHCl · The requirements

Systems and controllers

MDS › Monochloramine generation

… water to be treated. Two reagents The system combines ammonia (NH3) and sodium hypochlorite (NaClO) to produce monochloramine. PVDF reactor The two reagents and the dilution water are fed simultaneously into the reactor, up to a monochloramine concentration of …

Systems and controllers

Dechlorination of discharges › With water presence sensor

… – 800 or 0 – 8,000 g/h). The quantity is determined on the basis of the total chlorine in the pool, the flow rate of the recirculation pump and the quantity of product required to reduce the chlorine by 1 mg/l, stated on the label. Water presence sensor Capaci …

Also in: Where it is used · From the simplest to the most complete solution · Two systems: constant or volumetric · With pulse-output water meter

Systems and controllers

MAX5 › MAX5 functions

5 parameters Free, total and combined chlorine, chlorine dioxide, chlorites, hydrogen peroxide, peracetic acid, bromine, Redox, pH, dissolved oxygen, conductivity, ozone and tracers, with temperature measurement and compensation. Up to 12 pumps Proportional, O …

Systems and controllers

Volumetric dosing › From the simplest to the most complete solution

… Dual Parameter Simultaneous management of two parameters, for example pH and chlorine, with a single controller. Details → Centurio PRO Management of up to 10 parameters and of all the pumps in the installation, with touch screen and remote control as standard …

Systems and controllers

LDsCD › System remote control

… the plant supervision system. Real-time readings, counters and timers Free chlorine and temperature trends Set point and operating mode of each channel Status of relays, pulses, inputs and mA outputs

Systems and controllers

LDsDO › System remote control

… the plant supervision system. Real-time readings, counters and timers Free chlorine and temperature trends Set point and operating mode of each channel Status of relays, pulses, inputs and mA outputs

Systems and controllers

LDsETORB2 › System remote control

… the plant supervision system. Real-time readings, counters and timers Free chlorine and temperature trends Set point and operating mode of each channel Status of relays, pulses, inputs and mA outputs

Systems and controllers

LDsTRC › System remote control

… the plant supervision system. Real-time readings, counters and timers Free chlorine and temperature trends Set point and operating mode of each channel Status of relays, pulses, inputs and mA outputs

Contact

Tell us about your plant

Call or write to us: a technician will reply with a tailored proposal of controllers, pumps, probes and accessories.

What do you need?
Please enter your name.
Please enter a valid email address.
Please enter your message.

Describe your plant: type, water volume or flow rate, parameters to be controlled.

You must accept the privacy notice to continue.