Measuring and dosing systems

pH

The system continuously measures the pH of the water and controls one or more dosing pumps, which inject acid or base in proportion to the measured value up to the set pH (set point).

  • pH from 0 to 14
  • Acid and base dosing
  • Electrode in by-pass, in line or immersed
LDspH pH control system on a panel with dosing pump
SystempH control
LDspH controller
LDspHcontroller
How it works

Control principle

For wastewater, domestic water, drinking water, process water or swimming pool water: the required pH is set and the system maintains it automatically.

Learn more: adjusting pH →
Diagram of the LDspH system on a water storage tank: controller, pH electrode, chemical injection, acid or base tank and booster pump
1

Continuous measurement

The electrode continuously detects the pH of the water in the tank or in the pipe.

2

Proportional dosing

The controller activates one or more dosing pumps that inject the pH adjuster (acid or base) into the tank or pipe, in proportion to the measured pH, up to the set point.

3

pH restoration

At each draw-off, the incoming water comes into contact with the pH adjuster and the pump doses acid or base until the set pH is restored.

By adding a pulse-output water meter and a dosing pump connected to it, dosing also becomes proportional to the volume of water treated; the controller can also drive solenoid valves or other equipment according to the measured pH.

Acid and base

Acid and base dosing

Two different substances (generally an acid and a base) can be dosed into the same tank or pipe, or the same substance into two separate tanks or pipes.

Diagram of the LDspH system with two dosing pumps: acid and base injection on the storage tank supply pipe, immersed pH electrode, controller and booster pump
Components

Basic components

The system consists of the measuring controller, the electrode, the dosing pump for the pH adjuster and the suction and injection accessories.

LDspH controller

LDspH controller

It acquires the measurement from the electrode and controls the dosing pump in proportion to the measured value.

LDspH controller →
Combined pH electrodes

pH electrode

Combined electrode with single or double junction, also available in self-cleaning and low-conductivity versions.

pH electrodes →
VMS MF dosing pump

Dosing pump

Solenoid diaphragm pump, with flow rate and back pressure defined when ordering, controlled by the controller.

Dosing pumps →
Injection lance

Injection lance

It introduces the product into the centre of the pipe, improving mixing; it can be withdrawn with the pipe under pressure.

Lances →
Installation

Probe positioning

Probe positioning is defined according to the characteristics of the installation and of the water to be analysed.

PEF flow-through probe holder and NPED probe holder

In a bypass line

The probes are housed in a PEF flow-through probe holder or an NPED probe holder, connected to a sampling point at the tank outlet and fed with about 30 l/h of sample water. A flow sensor can be added, which stops dosing when there is no flow.

Probe holders →
Immersion probe holder

Immersion

The electrode is immersed directly in the storage tank of the water to be treated, by means of an immersion probe holder.

Probe holders →
Immersion probe holder with cleaning nozzle

Immersion with cleaning

A solution suited to water with a high solids load: at programmed intervals the control panel puts the controller in stand-by and opens a solenoid valve that sends water or air to the nozzle; once cleaning is complete, it closes the valve and, after the electrode repolarisation time has elapsed, resumes dosing.

Probe holders →
In-line probe holder

In-line

The electrodes are inserted directly into the pipe carrying the water to be treated.

Probe holders →
Applications

Applications

Domestic water circuits

Domestic water circuits

pH control in domestic water circuits.

Optional extras

Optional accessories

Accessories available on request to adapt the system to the requirements of the installation.

Tank

Tank

PE tanks for the chemical, with safety bund.

Details →
Pulse-output water meter

Pulse-output water meter

Enables dosing proportional to the volume of water actually treated.

Details →
Flow sensor

Flow sensor

Installed on the pump delivery line, it verifies that dosing actually takes place.

Details →
Static mixer

Static mixer

Ensures the chemical is mixed with the water and protects the pipe from direct contact with it.

Details →
Pulsation dampener

Pulsation dampener

Attenuates the pulsations generated by the dosing pump.

Details →
Injection lance

Injection lance

Injects the chemical into the centre of the pipe.

Details →
Multifunction valve

Multifunction valve

Pressure, safety and anti-siphon functions combined in a single valve.

Details →
Solenoid valve

Solenoid valve

Operated by the controller according to the measured value.

The controller

The LDspH controller

LDspH controller

LDspH

Measuring range, resolution, BASIC and PLUS versions, electrode self-cleaning, inputs, outputs and connections are given in the controller data sheet.

Which one to choose

From the simplest to the most complete solution

For pH control the basic solution is the dosing station; when dosing has to be controlled by the measured value, measuring controllers are used.

Dosing station on a tank

Dosing station

The simplest solution: the pump doses at a constant rate or in proportion to the volume of water measured by the pulse-output water meter.

Details →
LDspH system on a panel

LDspH – pH

pH measurement and dosing of acid or alkali up to the set value.

Details →
Two-channel LD system on a panel

LD Dual Parameter

Simultaneous management of two parameters, for example pH and chlorine, with a single controller.

Details →
Centurio PRO on a panel

Centurio PRO

Management of up to 10 parameters and of all the pumps in the installation, with touch screen and remote control as standard.

Details →
Remote control

System remote control

The controllers support two-way remote access (read and write) through the web portal from a PC, tablet or smartphone: measurements can be viewed, set points, dosing and alarms changed, alarms received and logs downloaded. Alternatively, they can be integrated into your PLC via Modbus.

Ethernet

Connection to the web portal via network cable: measurements, set points, dosing and alarms accessible from a PC, tablet or smartphone.

Optional (one only)

Wi-Fi

Wireless connection to the web portal, with the same functions as the cable connection.

Optional (one only)

4G

Connection via the 4G network for installations without a local network, with alarm notification by SMS or e-mail.

Optional (one only)
NIMBUS web portal for remote control of the systemsWeb portalPC, tablet and smartphone

Modbus RTU

Integration into your PLC via serial port.

Standard (BASIC), optional (PLUS)

0-4/20 mA current loop output

Current signal proportional to the measured value, for remote monitoring or for controlling pumps and other instrumentation.

3 standard (PLUS), 2 on request (BASIC)

USB port

Download of the logged data to a USB memory stick, for archiving and analysis with a spreadsheet.

Optional

One communication type at a time: Ethernet, Wi-Fi, 4G or Modbus RTU (built into the BASIC versions, optional on the PLUS versions). 0-4/20 mA current loop outputs standard on the PLUS versions, optional on the BASIC versions; meter input on the PLUS versions only.

The NIMBUS portal

A single account brings together all registered installations, each with its own devices: the web portal, free of charge and with no subscription, can be accessed from a PC, Mac, tablet or smartphone and allows every parameter to be both viewed and changed, with an encrypted connection and protected access.

The NIMBUS portal on monitor, laptop, tablet and smartphone

Overview

On a single screen: probe readings, chemical levels, pump activation thresholds and active alarms, with the status of installations and devices (normal, warning, alarm, standby, not connected).

Installation map

Installations appear on an interactive map with their status and open with a click; for each one, the local weather conditions and temperature are also shown.

History and charts

Archive of measurements and alarms, available for consultation at any time with charts and numerical reports exportable in Excel format.

Alarms and notifications

Alarm thresholds for readings, dosing, faulty probe and out-of-range readings, with notification by e-mail or SMS depending on the communication system; a warning is also issued when an installation remains disconnected beyond the set time.

Set points and dosing

Remote modification of the set points, of the dosing pump activation thresholds and of the corresponding hourly flow rate.

Inputs and outputs

Status of relays, pulse outputs, digital inputs and current outputs, with the name assigned to each connection.

Maintenance calendar

Tasks are scheduled by installation or by device and assigned to technicians; a reminder is sent by e-mail two days before the due date. Each task is shown as scheduled, due, overdue or completed.

Team and permissions

The main account has full access and creates the technicians’ accounts, each enabled only for the assigned installations and devices; the last login and activity of each technician are visible.

Reports and activity log

Reports on devices, tasks and technicians, downloadable in PDF or CSV with the customer’s logo; the log keeps the history of operations and disconnections.

Customisation

Logo, main colour and light or dark theme; the tiles on the main screen can be rearranged by dragging them. Two installations can be displayed side by side for comparison.

Guided registration

Each device is added through a guided procedure: the model is recognised automatically and associated with the installation, together with the technician to be contacted.

PLC integration

As an alternative to the portal, the Modbus RTU port allows integration into the plant supervision system.

NIMBUS portal: Real-time readings, counters and timers
Real-time readings, counters and timers
NIMBUS portal: Free chlorine and temperature trends
Free chlorine and temperature trends
NIMBUS portal: Set point and operating mode of each channel
Set point and operating mode of each channel
NIMBUS portal: Status of relays, pulses, inputs and mA outputs
Status of relays, pulses, inputs and mA outputs

Technical advice

Tell us the type of water, the volumes to be treated and the pH adjuster used: we will propose the most suitable electrode, probe holder, pump and accessories.

Contact

Tell us about your plant

Call or write to us: a technician will reply with a tailored proposal of controllers, pumps, probes and accessories.

What do you need?
Please enter your name.
Please enter a valid email address.
Please enter your message.

Describe your plant: type, water volume or flow rate, parameters to be controlled.

You must accept the privacy notice to continue.