Skip to content
Measuring and dosing systems

Wastewater treatment with Centurio PRO

In wastewater treatment plants a single Centurio PRO measures dissolved oxygen, pH, Redox, level, flow rate and turbidity and manages the dosing, timed or proportional to the flow rate, of flocculant, caustic soda, nutrients, acid, antifoam and chlorine.

  • Up to 10 channels
  • Dissolved oxygen, pH and Redox
  • Level, flow rate and turbidity
Centurio PRO on a panel with dosing pumps
On a panel
Centurio PRO multi-parameter controller
Centurio PRO
Typical layout

Typical layout

How the plant works, one step at a time: a single controller for the measurements in the contact tank and in the treated water and for all the dosing pumps.

Wastewater treatment layout, step 1: dissolved oxygen probe in the contact tank
1

Dissolved oxygen

The optical probe measures the dissolved oxygen in the contact tank.

Components

Basic components

Centurio PRO

Centurio PRO

Multi-channel controller with touch screen: up to 10 measuring channels and control of all the dosing pumps in the plant.

Centurio PRO →
EOLUM optical dissolved oxygen probe

Dissolved oxygen probe

Optical fluorescence probe: the measurement does not consume oxygen and is possible even in still water.

The probe →
pH electrodes

pH and Redox electrodes

The pH electrode in the contact tank controls caustic soda and acid; the Redox electrode in the treated water storage tank controls chlorine.

ETORB2 turbidity probe

Turbidimeter

Turbidity probe in a bypass line on the line to the receiving water body, with drain valve for cleaning.

Turbidity →
Pulse-output water meter

Pulse-output water meter

Turbine or Woltmann type, on the line to the receiving water body: it measures the treated water leaving the plant.

Water meters →
Dosing pump

Dosing pumps

Solenoid dosing pumps with adjustable flow rate, driven by the Centurio PRO: one for each product.

Dosing pumps →
1

Contact tank

In the contact tank the Centurio PRO measures dissolved oxygen and pH and controls the caustic soda and acid pumps, which maintain the pH at the set value.

2

Process dosing

Flocculant, nutrients and antifoam are dosed on a timed basis or in proportion to the flow rate.

3

Treated water

In the treated water storage tank the controller measures level and Redox and doses chlorine according to the measured value.

4

Outlet to the receiving water body

The water meter measures the water discharged to the receiving water body and the bypass turbidity meter checks its turbidity, diverting the turbid sample to drain.

Installation

In a cabinet or in the plant room

Controller, pumps, probe holder and accessories are supplied pre-assembled on a panel, in a box or on a skid, with configurable dimensions.

Centurio PRO installed in a cabinet with dosing pumps and tanks

In a cabinet

The controller, the pumps and the product tanks are housed in a cabinet.

Wall-mounted Centurio PRO with dosing pumps and product tanks

In the plant room

The controller and the pumps are wall-mounted on a panel, with the product tanks on the floor.

Technical data

Probe data sheet

Dissolved oxygen probes
EOLUM
Measuring range0 – 20 mg/l
Resolution0.01
Measuring systemFluorescence
Automatic compensationTemperature and pressure
Operating temperature−5 / +50 °C
Operating pressure10 bar
BodyStainless steel
pH electrodes
ElectrodePressureConnectionBodyMinimum conductivityJunctionTemperatureCableDiameterNotes
EpHS7 bar (3.5 bar)BNCEpoxy100 µS–70 °C (80 °C)0.8 m12 mm–
EpHM7 bar (3.5 bar)BNCEpoxy100 µS–70 °C (80 °C)4.5 m12 mm–
EpHL7 bar (3.5 bar)BNCEpoxy100 µS–70 °C (80 °C)15 m12 mm–
EpHSN67 bar (3.5 bar)SN6 with PG13.5 threadEpoxy100 µS–70 °C (80 °C)1 – 100 m12 mm–
EpHMD/1007 barBNCEpoxy100 µSDouble100 °C4.5 m12 mm–
EpHM/D7 bar (3.5 bar)BNCEpoxy100 µSDouble70 °C (80 °C)4.5 m12 mm–
EpHM/D/SN67 bar (3.5 bar)SN6 with PG13.5 threadEpoxy100 µSDouble70 °C (80 °C)1 – 100 m12 mm–
EpHMD/LI7 bar (3.5 bar)SN6 with PG13.5 threadEpoxy3 µSDouble70 °C (80 °C)1 – 100 m12 mmFor low-conductivity water
EpHSC7 bar (3.5 bar)BNCEpoxy100 µSDouble70 °C (80 °C)4.5 m12 mmSelf-cleaning
EpHSC/SN67 bar (3.5 bar)SN6 with PG13.5 threadEpoxy100 µSDouble70 °C (80 °C)1 – 100 m12 mmSelf-cleaning
EpHM/HF7 bar (3.5 bar)BNCEpoxy100 µSDouble70 °C (80 °C)4.5 m12 mmResistant to 1% hydrofluoric acid
EpHSN6 GK10 barSN6Glass150 µS–−5 / 135 °C1 – 100 m12 mmHigh temperature

All models: combination electrode, range 0 – 14 pH, resolution 0.01.

Redox electrodes
ElectrodeRangePressureConnectionBodyMinimum conductivityJunctionTemperatureCableDiameterNotes
ERhS± 1,000 mV7 bar (3.5 bar)BNCEpoxy100 µS–70 °C (80 °C)0.8 m12 mm–
ERhM± 1,000 mV7 bar (3.5 bar)BNCEpoxy100 µS–70 °C (80 °C)4.5 m12 mm–
ERhL± 1,000 mV7 bar (3.5 bar)BNCEpoxy100 µS–70 °C (80 °C)15 m12 mm–
ERhHLB SN6± 1,500 mV6 barSN6 with PG13.5 threadGlass100 µS–80 °C10 m12 mmHigh linearity and sensitivity, for low chlorine concentrations
ERhSN6± 1,000 mV7 barSN6 with PG13.5 threadEpoxy100 µS–100 °C1 – 100 m12 mm–
ERhMD/100± 1,000 mV7 barBNCEpoxy100 µSDouble100 °C4.5 m12 mm–
ERhM/D± 1,000 mV7 bar (3.5 bar)BNCEpoxy100 µSDouble70 °C (80 °C)4.5 m12 mm–
ERhSC± 1,000 mV7 bar (3.5 bar)BNCEpoxy100 µSDouble70 °C (80 °C)4.5 m12 mmSelf-cleaning
ERhSC/SN6± 1,000 mV7 bar (3.5 bar)SN6 with PG13.5 threadEpoxy100 µSDouble70 °C (80 °C)1 – 100 m12 mmSelf-cleaning

All models: combination electrode, resolution 1 mV.

Turbidity probe
ETORB2
Measuring range0/40 NTU – 0/400 NTU – 0/4,000 NTU
Measurement error± 5% of reading
Measuring systemNIR scattered light at 90°, nephelometric principle
BodyPVC
Optical windowSapphire glass
Automatic compensationTemperature
Self-cleaning●(water jet, max 1 bar)
Operating temperature0 – 40 °C
Operating pressure2 bar
Remote control

System remote control

The controllers support two-way remote access (read and write) through the web portal from a PC, tablet or smartphone: measurements can be viewed, set points, dosing and alarms changed, alarms received and logs downloaded. Alternatively, they can be integrated into your PLC via Modbus.

Ethernet

Connection to the web portal via network cable: measurements, set points, dosing and alarms accessible from a PC, tablet or smartphone.

Standard

Wi-Fi

Wireless connection to the web portal, with the same functions as the cable connection.

Standard

USB port

Download of the logged data to a USB memory stick, for archiving and analysis with a spreadsheet.

Standard
NIMBUS web portal for remote control of the systemsWeb portalPC, tablet and smartphone

Modbus RTU

Integration into your PLC via serial port.

Standard

Modbus TCP/IP

Integration into your PLC or SCADA via Ethernet network.

Standard

0-4/20 mA current loop output

Current signal proportional to the measured value, for remote monitoring or for controlling pumps and other instrumentation.

Standard

4G

Connection via the 4G network for installations without a local network, with alarm notification by SMS or e-mail.

Optional

Ethernet, Wi-Fi, USB, Modbus RTU, Modbus TCP/IP and 0-4/20 mA current loop outputs as standard; 4G modem optional.

The NIMBUS portal

A single account brings together all registered installations, each with its own devices: the web portal, free of charge and with no subscription, can be accessed from a PC, Mac, tablet or smartphone and allows every parameter to be both viewed and changed, with an encrypted connection and protected access.

The NIMBUS portal on monitor, laptop, tablet and smartphone

Overview

On a single screen: probe readings, chemical levels, pump activation thresholds and active alarms, with the status of installations and devices (normal, warning, alarm, standby, not connected).

Installation map

Installations appear on an interactive map with their status and open with a click; for each one, the local weather conditions and temperature are also shown.

History and charts

Archive of measurements and alarms, available for consultation at any time with charts and numerical reports exportable in Excel format.

Alarms and notifications

Alarm thresholds for readings, dosing, faulty probe and out-of-range readings, with notification by e-mail or SMS depending on the communication system; a warning is also issued when an installation remains disconnected beyond the set time.

Set points and dosing

Remote modification of the set points, of the dosing pump activation thresholds and of the corresponding hourly flow rate.

Inputs and outputs

Status of relays, pulse outputs, digital inputs and current outputs, with the name assigned to each connection.

Maintenance calendar

Tasks are scheduled by installation or by device and assigned to technicians; a reminder is sent by e-mail two days before the due date. Each task is shown as scheduled, due, overdue or completed.

Team and permissions

The main account has full access and creates the technicians’ accounts, each enabled only for the assigned installations and devices; the last login and activity of each technician are visible.

Reports and activity log

Reports on devices, tasks and technicians, downloadable in PDF or CSV with the customer’s logo; the log keeps the history of operations and disconnections.

Customisation

Logo, main colour and light or dark theme; the tiles on the main screen can be rearranged by dragging them. Two installations can be displayed side by side for comparison.

Guided registration

Each device is added through a guided procedure: the model is recognised automatically and associated with the installation, together with the technician to be contacted.

PLC integration

As an alternative to the portal, the Modbus RTU or TCP/IP port allows integration into the plant supervision system.

NIMBUS portal: Real-time readings, counters and timers
Real-time readings, counters and timers
NIMBUS portal: Free chlorine and temperature trends
Free chlorine and temperature trends
NIMBUS portal: Set point and operating mode of each channel
Set point and operating mode of each channel
NIMBUS portal: Status of relays, pulses, inputs and mA outputs
Status of relays, pulses, inputs and mA outputs

System design

Describe the wastewater treatment plant, the tanks and the products to be dosed: we will size controller, probes, pumps and accessories and supply the system assembled on a panel, in a box or on a skid.

Contact

Tell us about your plant

Call or write to us: a technician will reply with a tailored proposal of controllers, pumps, probes and accessories.

What do you need?
Please enter your name.
Please enter a valid email address.
Please enter your message.

Describe your plant: type, water volume or flow rate, parameters to be controlled.

You must accept the privacy notice to continue.