Measuring and dosing systems

Conductivity

The system continuously measures the conductivity of the water, which depends on the amount of dissolved salts, and according to the set values (set points) starts or stops the dosing of chemical products or controls the opening and closing of the inlet and drain solenoid valves.

  • Conductivity in µS or mS
  • Contacting or inductive probes
  • Temperature compensation with PT100
  • Control of pumps and solenoid valves
LDsCD system pre-assembled on a panel with two dosing pumps and filters
Systemconductivity
LDsCD controller
LDsCD
How it works

Control principle

The probe, immersed in the storage tank or installed on the pipe, sends the conductivity of the water to the controller; the controller compares it with the set values and drives the dosing pumps, solenoid valves or other equipment connected to its outputs accordingly.

Layout of the LDsCD system on a water storage tank: controller, immersed conductivity probe, product injection, chemical product tank and booster pump
1

Continuous measurement

The probe continuously detects conductivity, in the µS or mS range depending on the model, and the controller automatically compensates for the effect of temperature, measured with a PT100 probe.

2

ON/OFF control

The output is activated when the ON set point is exceeded and deactivated when the OFF set point is reached; when conductivity returns to the ON set point, the output is activated again.

3

Dosing, inlet and drain

The dosing pumps dose the chemical products according to the measured conductivity, while solenoid valves or motorised valves manage the inlet and drain of the water.

For example, with the ON set point at 2.00 mS and the OFF set point at 1.50 mS, the output is activated when conductivity exceeds 2.00 mS and remains active until it falls to 1.50 mS.

Components

Basic components

The system consists of the measuring controller, the conductivity probe and the controlled equipment: dosing pumps for the chemical products, solenoid valves or motorised valves for the inlet and drain of the water. It can be supplied pre-assembled on a panel, ready for connection.

LDsCD controller

LDsCD controller

It acquires the measurement from the probe and drives dosing pumps, solenoid valves or other equipment according to the detected value.

LDsCD controller →
VMS MF dosing pump

Dosing pump

Electromagnetic diaphragm pump, with flow rate and back pressure defined when ordering, driven by the controller.

Dosing pumps →
Motorised ball valve driven by the controller

Motorised valve

Operated by the controller according to the measured conductivity, it opens and closes the water inlet or drain.

Probes

Contacting or inductive probe

The probe is selected according to the required measuring range and the quality of the water: contacting probes have graphite, stainless steel or platinum electrodes; the inductive probe has no electrodes in contact with the water and is unaffected by polarisation and deposits.

Contacting conductivity probes

Contacting probes

Four series are available: PVDF body with stainless steel electrodes (0 – 200 µS or 0 – 5 mS) or graphite electrodes (0 – 20 or 0 – 200 mS), stainless steel body and electrodes for immersion and high temperatures, epoxy body with high-linearity platinum electrodes.

Contacting probes →
Inductive conductivity probes

Inductive probe

It provides a particularly stable and accurate reading, measures even in still water up to 300 mS and is also suitable for hot water, high-pressure water and water containing suspended solids. It must be installed with the flow directed at the end of the probe.

Inductive probes →
Installation

Probe positioning

Probe positioning is defined according to the characteristics of the installation and of the water to be analysed.

PEF flow-through probe holder and NPED probe holder

In a bypass line

The probes are housed in a PEF flow-through probe holder or an NPED probe holder, connected to a sampling point at the tank outlet and fed with about 30 l/h of sample water. A flow sensor can be added, which stops dosing when there is no flow.

Probe holders →
Immersion probe holder

Immersion

The electrode is immersed directly in the storage tank of the water to be treated, by means of an immersion probe holder.

Probe holders →
In-line probe holder

In-line

The electrodes are inserted directly into the pipe carrying the water to be treated.

Probe holders →
Probe position

Correct probe positioning

A reliable reading requires the flow to strike the end of the probe: air bubbles and sediment deposits alter the measurement and, consequently, the control of the pumps and valves.

Correct installation: probe with the flow directed at its end

Correct

The flow is directed at the end of the probe.

Correct installation on a vertical section

Correct

The probe is on a vertical section, with upward flow.

Incorrect installation: deposits of solids on the probe

Incorrect

Impurities and solids settle on the probe.

Incorrect installation: air bubbles around the probe

Incorrect

Air bubbles form around the probe.

Incorrect installation: air bubbles around the probe

Incorrect

Air bubbles collect around the probe.

Incorrect installation: air bubbles and deposits of solids

Incorrect

The probe is exposed to air bubbles and deposits of solids.

Applications

Applications

Domestic water circuits

Domestic water circuits

In domestic water circuits the system monitors conductivity and controls dosing or drain according to the measured value.

Cooling towers

Cooling towers

In cooling towers, bleed-off according to conductivity, together with the dosing of antiscalant and biocides, is managed by dedicated systems: WT pump, MTOWER and Centurio Tower.

Cooling tower systems →
Optional extras

Optional accessories

Accessories available on request to adapt the system to the requirements of the installation.

Tank

Tank

PE tanks for the chemical, with safety bund.

Details →
Pulse-output water meter

Pulse-output water meter

Enables dosing proportional to the volume of water actually treated.

Details →
Flow sensor

Flow sensor

Installed on the pump delivery line, it verifies that dosing actually takes place.

Details →
Static mixer

Static mixer

Ensures the chemical is mixed with the water and protects the pipe from direct contact with it.

Details →
Pulsation dampener

Pulsation dampener

Attenuates the pulsations generated by the dosing pump.

Details →
Injection lance

Injection lance

Injects the chemical into the centre of the pipe.

Details →
Multifunction valve

Multifunction valve

Pressure, safety and anti-siphon functions combined in a single valve.

Details →
The controller

The LDsCD controller

LDsCD controller

LDsCD

Measuring ranges, resolution, BASIC and PLUS versions, connectable probes, inputs, outputs and connections are given in the controller data sheet.

Which one to choose

From the simplest to the most complete solution

For conductivity control the basic solution is the dosing station; when dosing has to be controlled by the measured value, measuring controllers are used.

Dosing station on a tank

Dosing station

The simplest solution: the pump doses at a constant rate or in proportion to the volume of water measured by the pulse-output water meter.

Details →
LDsCD system on a panel

LDsCD – conductivity

Conductivity measurement with contacting or inductive probes and dosing up to the set value.

Details →
Two-channel LD system on a panel

LD Dual Parameter

Simultaneous management of two parameters, for example pH and chlorine, with a single controller.

Details →
Centurio PRO on a panel

Centurio PRO

Management of up to 10 parameters and of all the pumps in the installation, with touch screen and remote control as standard.

Details →
Remote control

System remote control

The controllers support two-way remote access (read and write) through the web portal from a PC, tablet or smartphone: measurements can be viewed, set points, dosing and alarms changed, alarms received and logs downloaded. Alternatively, they can be integrated into your PLC via Modbus.

Ethernet

Connection to the web portal via network cable: measurements, set points, dosing and alarms accessible from a PC, tablet or smartphone.

Optional (one only)

Wi-Fi

Wireless connection to the web portal, with the same functions as the cable connection.

Optional (one only)

4G

Connection via the 4G network for installations without a local network, with alarm notification by SMS or e-mail.

Optional (one only)
NIMBUS web portal for remote control of the systemsWeb portalPC, tablet and smartphone

Modbus RTU

Integration into your PLC via serial port.

Standard (BASIC), optional (PLUS)

0-4/20 mA current loop output

Current signal proportional to the measured value, for remote monitoring or for controlling pumps and other instrumentation.

3 standard (PLUS), 2 on request (BASIC)

USB port

Download of the logged data to a USB memory stick, for archiving and analysis with a spreadsheet.

Optional

One communication type at a time: Ethernet, Wi-Fi, 4G or Modbus RTU (built into the BASIC versions, optional on the PLUS versions). 0-4/20 mA current loop outputs standard on the PLUS versions, optional on the BASIC versions; meter input on the PLUS versions only.

The NIMBUS portal

A single account brings together all registered installations, each with its own devices: the web portal, free of charge and with no subscription, can be accessed from a PC, Mac, tablet or smartphone and allows every parameter to be both viewed and changed, with an encrypted connection and protected access.

The NIMBUS portal on monitor, laptop, tablet and smartphone

Overview

On a single screen: probe readings, chemical levels, pump activation thresholds and active alarms, with the status of installations and devices (normal, warning, alarm, standby, not connected).

Installation map

Installations appear on an interactive map with their status and open with a click; for each one, the local weather conditions and temperature are also shown.

History and charts

Archive of measurements and alarms, available for consultation at any time with charts and numerical reports exportable in Excel format.

Alarms and notifications

Alarm thresholds for readings, dosing, faulty probe and out-of-range readings, with notification by e-mail or SMS depending on the communication system; a warning is also issued when an installation remains disconnected beyond the set time.

Set points and dosing

Remote modification of the set points, of the dosing pump activation thresholds and of the corresponding hourly flow rate.

Inputs and outputs

Status of relays, pulse outputs, digital inputs and current outputs, with the name assigned to each connection.

Maintenance calendar

Tasks are scheduled by installation or by device and assigned to technicians; a reminder is sent by e-mail two days before the due date. Each task is shown as scheduled, due, overdue or completed.

Team and permissions

The main account has full access and creates the technicians’ accounts, each enabled only for the assigned installations and devices; the last login and activity of each technician are visible.

Reports and activity log

Reports on devices, tasks and technicians, downloadable in PDF or CSV with the customer’s logo; the log keeps the history of operations and disconnections.

Customisation

Logo, main colour and light or dark theme; the tiles on the main screen can be rearranged by dragging them. Two installations can be displayed side by side for comparison.

Guided registration

Each device is added through a guided procedure: the model is recognised automatically and associated with the installation, together with the technician to be contacted.

PLC integration

As an alternative to the portal, the Modbus RTU port allows integration into the plant supervision system.

NIMBUS portal: Real-time readings, counters and timers
Real-time readings, counters and timers
NIMBUS portal: Free chlorine and temperature trends
Free chlorine and temperature trends
NIMBUS portal: Set point and operating mode of each channel
Set point and operating mode of each channel
NIMBUS portal: Status of relays, pulses, inputs and mA outputs
Status of relays, pulses, inputs and mA outputs

Technical advice

Tell us the type of water, the conductivity to be maintained and the equipment to be controlled: we will propose the most suitable probe, probe holder, pumps, valves and accessories.

Contact

Tell us about your plant

Call or write to us: a technician will reply with a tailored proposal of controllers, pumps, probes and accessories.

What do you need?
Please enter your name.
Please enter a valid email address.
Please enter your message.

Describe your plant: type, water volume or flow rate, parameters to be controlled.

You must accept the privacy notice to continue.