DIN Digital controller · RHDIN
Single-channel DIN-rail controller, 6 modules, with two ON/OFF or proportional volt-free contact outputs and one programmable 0-4/20 mA output.
DIN Digital →The system continuously measures the Redox potential (ORP) of the water, expressed in mV, which indicates its disinfecting power, with the DIN Digital Redox controller mounted on a DIN rail in the electrical panel of the plant. According to the set points it drives the dosing pumps for hypochlorite or another disinfectant, including those already installed, and the motorised valves; the 0-4/20 mA output retransmits the measurement or drives a pump directly, for example with 4 mA at 600 mV and 20 mA at 650 mV.
The controller is completed by the Redox electrode, the probe holder, the disinfectant dosing pump and the shut-off accessories of the plant.
Single-channel DIN-rail controller, 6 modules, with two ON/OFF or proportional volt-free contact outputs and one programmable 0-4/20 mA output.
DIN Digital →
Combined electrode, also available in a high-linearity, high-sensitivity version, designed to detect the very low free chlorine concentrations typical of drinking water.
Redox electrodes →
Probe holder connected in a bypass line to the circuit, with 5" filter with washable 60 µm PET cartridges or 100 µm wound cartridges (maximum 5 bar).
Probe holders →
Flow rate and back pressure defined at the time of ordering, wetted parts in PVDF, PP, PVC or stainless steel. Supplied with a pre-calibrated injection valve and a magnetic level probe with foot suction pipe, which stops the pump when the chemical runs out.
Dosing pumps →
Installed on the pump delivery, it checks the passage of the liquid: in the event of a fault the pump performs automatic re-priming and recovers the missed injections; if the anomaly persists, it is also signalled remotely.
Flow sensor →
Connected to a set-point-controlled volt-free contact output, they shut off the water inlet or outlet according to the measured value.
The set points of the parameter to be controlled are entered; the controller drives the connected equipment automatically and continuously.
The probe, installed in a probe holder in a bypass line, in line or immersed, continuously detects the parameter; the display shows the measured value, the set points and the proportional band. The programmable delay waits for the probe to polarise before starting control.
The two volt-free contact outputs control the pumps in ON/OFF or proportional mode, for example for acid and base, or for the same chemical at two injection points; the 0-4/20 mA output retransmits the measurement or drives a pump directly over the proportional band.
The volt-free contact outputs control pumps already installed, motorised valves that shut off the water inlet or outlet, or the start and stop of the ozone generator, when the set points are reached.
The flow sensor input allows dosing to be suspended when no water flows through the probe holder and the measurement is not representative.
The probes, the flow sensor and the controlled loads are connected to the terminal board of the controller.
The controller has no dedicated alarm output: alarm conditions are shown on the display.
The controller is mounted on a DIN rail, 6 modules, in the electrical panel of the plant, next to the other control devices; ABS housing, IP40 protection, 24, 115 or 230 VAC or 24 VDC power supply.

The controller is installed in the existing panel or in its own enclosure with transparent cover, ready for connection; several controllers can be connected to each other in Master/Slave mode.
The sample water is taken with a T-fitting on the pipe, flows through the filter and the probe holder and returns to the circuit or to drain.
Probe holders →The system is used wherever the disinfecting power of the water must be kept constant with a simple and economical solution.
In raw water from private wells and springs and from public water supply networks, hypochlorite is dosed according to the Redox potential measured in the storage tank.
In fire-fighting water reserves the electrode is immersed in the tank and the system maintains the disinfecting power of the water by automatically dosing hypochlorite.
In domestic water circuits the system maintains the set Redox potential as consumption varies.
In water used in industrial processes, disinfectant dosing follows the variations in the pollutant load.
Learn more: industrial water →
In municipal and industrial wastewater the system adjusts disinfectant dosing to the potential actually measured.

Versions and code prefixes, parameters, measuring ranges, inputs, outputs and technical characteristics are given on the controller page.
Accessories available on request to adapt the system to the requirements of the installation.
PE tanks for the chemical, with safety bund.
Details →
Injects the chemical into the centre of the pipe.
Details →
Pressure, safety and anti-siphon functions combined in a single valve.
Details →
Ensures the chemical is mixed with the water and protects the pipe from direct contact with it.
Details →
Attenuates the pulsations generated by the dosing pump.
Details →Tell us the parameter to be controlled, the characteristics of the panel and the equipment to be driven: we will propose the most suitable probe, pumps and accessories.
Call or write to us: a technician will reply with a tailored proposal of controllers, pumps, probes and accessories.