Measurement and control

DIN Digital

The DIN Digital is a single-channel controller for DIN rail mounting in the electrical panel of the plant, available for pH, Redox, conductivity, free chlorine, chlorine dioxide, ozone or temperature. Its two volt-free contact outputs drive, in ON/OFF or proportional mode, dosing pumps, including existing ones, solenoid valves or the ozone generator; the 0-4/20 mA output retransmits the measurement or drives a pump directly.

  • DIN rail, 6 modules
  • 2 volt-free contact outputs
  • Programmable 0-4/20 mA output
  • Master/Slave connection
DIN Digital panel controller on DIN rail
DIN Digital6 modules
DIN Digital controller mounted in an enclosure with transparent cover
In enclosure
6DIN modules
2Volt-free contact outputs
4WAverage power consumption
IP40Protection rating
The model

DIN Digital

DIN Digital controller
DIN rail · 6 modules

DIN Digital

For pH, Redox, conductivity, free chlorine, chlorine dioxide, ozone and temperature. Two ON/OFF or proportional digital outputs (for example acid and base, or the same chemical at two injection points) and one 0-4/20 mA current loop output.

Available versions
In enclosure In enclosureAlso available in an enclosure with transparent cover.
Control

Digital logic and control modes

The alphanumeric display shows the measured value, the set points and the proportional band. The housing is made of ABS, with IP40 protection rating.

Time-proportional (100-second cycle)

The output remains active for a fraction of the 100-second period proportional to the deviation from the set point: for example, at pH 7.30 it remains active for 30 seconds and inactive for 70. ON/OFF control is available as an alternative.

Proportional 0-4/20 mA current loop

The current output drives the pump directly over the proportional band: 4 mA at SET POINT ON (maximum strokes) and 20 mA at SET POINT OFF (pump stopped), for example 4 mA at pH 8 and 20 mA at pH 7 with acid dosing, or 4 mA at 600 mV and 20 mA at 650 mV for Redox.

Existing pumps and solenoid valves

The volt-free contact outputs control pumps already installed and solenoid valves that shut off the water inlet or outlet when the set points are reached.

Inputs and outputs

Inputs, outputs and alarms

The probes, the flow sensor and the controlled loads are connected to the terminal board of the controller.

Inputs

  • Parameter probe: BNC connector for pH and Redox electrodes, terminal board for conductivity probes, amperometric cells and temperature probes
  • NTC 10K temperature probe for the compensation of the pH and conductivity measurement
  • SEPR flow sensor or volt-free contact, which can be shared by two controllers connected in Master/Slave mode

Outputs

  • 2 volt-free contact outputs (set points 1 and 2), in ON/OFF mode or proportional over a 100-second period
  • 0-20 or 4-20 mA current output, programmable and galvanically isolated, maximum load 350 Ω, for a dosing pump or a recorder

Alarms

  • No flow: NO FLOW message and control stopped
  • Probe calibration errors, shown on the display

The controller has no dedicated alarm output: alarm conditions are shown on the display.

In enclosure

DIN rail mounting

The controller clips onto the DIN rail of the electrical panel of the plant, next to the other control devices, and takes up 6 modules; it is also available in its own enclosure with transparent cover, ready for connection.

DIN Digital controller clipping onto the DIN rail of the electrical panel, 6 modules
DIN Digital controller mounted in an enclosure with transparent cover

DIN Digital in enclosure

DIN controller mounted in its enclosure, ready for connection.

Probes

Measurable parameters and probes

The controller connects to the same probes as the LD controllers; the data sheets are given further down.

Combination pH electrodes

pH

Combination electrodes, including double-junction, self-cleaning or for low conductivity.

pH electrodes →
Contacting conductivity probes

Contacting conductivity

Probes with graphite, stainless steel or platinum electrodes.

Contacting probes →
Amperometric cells for free chlorine

Free chlorine

Closed amperometric cells with selective membrane, pH and temperature compensation.

SCL cells →
SCL2 and SCL17 amperometric cells for chlorine dioxide

Chlorine dioxide

SCL2 closed amperometric cells and SCL17 self-cleaning cells for hot water.

SCL cells →
Closed amperometric cell for ozone

Ozone

SCL10 closed amperometric cell with selective membrane.

SCL10 cell →

Probe data sheets

pH electrodes
ElectrodePressureConnectionBodyMinimum conductivityJunctionTemperatureCableDiameterNotes
EpHS7 bar (3.5 bar)BNCEpoxy100 µS–70 °C (80 °C)0.8 m12 mm–
EpHM7 bar (3.5 bar)BNCEpoxy100 µS–70 °C (80 °C)4.5 m12 mm–
EpHL7 bar (3.5 bar)BNCEpoxy100 µS–70 °C (80 °C)15 m12 mm–
EpHSN67 bar (3.5 bar)SN6 with PG13.5 threadEpoxy100 µS–70 °C (80 °C)1 – 100 m12 mm–
EpHMD/1007 barBNCEpoxy100 µSDouble100 °C4.5 m12 mm–
EpHM/D7 bar (3.5 bar)BNCEpoxy100 µSDouble70 °C (80 °C)4.5 m12 mm–
EpHM/D/SN67 bar (3.5 bar)SN6 with PG13.5 threadEpoxy100 µSDouble70 °C (80 °C)1 – 100 m12 mm–
EpHMD/LI7 bar (3.5 bar)SN6 with PG13.5 threadEpoxy3 µSDouble70 °C (80 °C)1 – 100 m12 mmFor low-conductivity water
EpHSC7 bar (3.5 bar)BNCEpoxy100 µSDouble70 °C (80 °C)4.5 m12 mmSelf-cleaning
EpHSC/SN67 bar (3.5 bar)SN6 with PG13.5 threadEpoxy100 µSDouble70 °C (80 °C)1 – 100 m12 mmSelf-cleaning
EpHM/HF7 bar (3.5 bar)BNCEpoxy100 µSDouble70 °C (80 °C)4.5 m12 mmResistant to 1% hydrofluoric acid
EpHSN6 GK10 barSN6Glass150 µS–−5 / 135 °C1 – 100 m12 mmHigh temperature

All models: combination electrode, range 0 – 14 pH, resolution 0.01.

Redox electrodes
ElectrodeRangePressureConnectionBodyMinimum conductivityJunctionTemperatureCableDiameterNotes
ERhS± 1,000 mV7 bar (3.5 bar)BNCEpoxy100 µS–70 °C (80 °C)0.8 m12 mm–
ERhM± 1,000 mV7 bar (3.5 bar)BNCEpoxy100 µS–70 °C (80 °C)4.5 m12 mm–
ERhL± 1,000 mV7 bar (3.5 bar)BNCEpoxy100 µS–70 °C (80 °C)15 m12 mm–
ERhHLB SN6± 1,500 mV6 barSN6 with PG13.5 threadGlass100 µS–80 °C10 m12 mmHigh linearity and sensitivity, for low chlorine concentrations
ERhSN6± 1,000 mV7 barSN6 with PG13.5 threadEpoxy100 µS–100 °C1 – 100 m12 mm–
ERhMD/100± 1,000 mV7 barBNCEpoxy100 µSDouble100 °C4.5 m12 mm–
ERhM/D± 1,000 mV7 bar (3.5 bar)BNCEpoxy100 µSDouble70 °C (80 °C)4.5 m12 mm–
ERhSC± 1,000 mV7 bar (3.5 bar)BNCEpoxy100 µSDouble70 °C (80 °C)4.5 m12 mmSelf-cleaning
ERhSC/SN6± 1,000 mV7 bar (3.5 bar)SN6 with PG13.5 threadEpoxy100 µSDouble70 °C (80 °C)1 – 100 m12 mmSelf-cleaning

All models: combination electrode, resolution 1 mV.

Contacting probes – ECDC

PVDF body, graphite electrodes.

ModelMountingConnectionRangeK factorTemperature compensation
ECDC/1In-line / bypassR3/4"0 – 20 mS1–
ECDCC/1In-line / bypassR3/4"0 – 20 mS1NTC 10K
ECDCCPT/1In-line / bypassR3/4"0 – 20 mS1PT100
ECDC/10In-line / bypassR3/4"0 – 200 mS10–
ECDCC/10In-line / bypassR3/4"0 – 200 mS10NTC 10K
ECDCCPT/10In-line / bypassR3/4"0 – 200 mS10PT100
ECDCIM/1ImmersionG1/2"0 – 20 mS1–
ECDCCIM/1ImmersionG1/2"0 – 20 mS1NTC 10K
ECDCCIMPT/1ImmersionG1/2"0 – 20 mS1PT100
ECDCIM/10ImmersionG1/2"0 – 200 mS10–
ECDCCIM/10ImmersionG1/2"0 – 200 mS10NTC 10K
ECDCCIMPT/10ImmersionG1/2"0 – 200 mS10PT100

Operating temperature 1 – 60 °C (100 °C at 2 bar), operating pressure 7 bar (2 bar at 100 °C).

Contacting probes – ECDI

PVDF body, stainless steel electrodes.

ModelMountingConnectionRangeK factorTemperature compensation
ECDI/1In-line / bypassR3/4"0 – 5 mS1–
ECDIC/1In-line / bypassR3/4"0 – 5 mS1NTC 10K
ECDICPT/1In-line / bypassR3/4"0 – 5 mS1PT100
ECDI/01In-line / bypassR3/4"0 – 200 µS0.1–
ECDIC/01In-line / bypassR3/4"0 – 200 µS0.1NTC 10K
ECDICPT/01In-line / bypassR3/4"0 – 200 µS0.1PT100
ECDIIM/1ImmersionG1/2"0 – 5 mS1–
ECDICIM/1ImmersionG1/2"0 – 5 mS1NTC 10K
ECDICPTIM/1ImmersionG1/2"0 – 5 mS1PT100
ECDIIM/01ImmersionG1/2"0 – 200 µS0.1–
ECDIIM/02ImmersionG1/2"0 – 500 µS0.2–
ECDICIM/01ImmersionG1/2"0 – 200 µS0.1NTC 10K
ECDICPTIM/01ImmersionG1/2"0 – 200 µS0.1PT100

Operating temperature 1 – 60 °C (100 °C at 2 bar), operating pressure 7 bar (2 bar at 100 °C).

Contacting probes – ECDHL

Epoxy body, platinum electrodes, diameter 12 mm.

ModelMountingRangeK factorTemperature compensation
ECDHL/1In-line / bypass0.2 – 20 mS1–
ECDHLC/1In-line / bypass0.2 – 20 mS1NTC 10K
ECDHLCPT/1In-line / bypass0.2 – 20 mS1PT100
ECDHL/01In-line / bypass0 – 200 µS0.1–
ECDHLC/01In-line / bypass0 – 200 µS0.1NTC 10K
ECDHLCPT/01In-line / bypass0 – 200 µS0.1PT100
ECDHL/10In-line / bypass20 – 200 mS10–
ECDHLC/10In-line / bypass20 – 200 mS10NTC 10K
ECDHLCPT/10In-line / bypass20 – 200 mS10PT100

Operating temperature 1 – 70 °C, operating pressure 7 bar.

Contacting probes – EICDC

Stainless steel body and electrodes, R3/4" connection, in-line or bypass mounting.

ModelRangeK factorTemperature compensationOperating temperature
EICDC/10 – 20 mS1NTC 10K1 – 130 °C
EICDCPT/10 – 20 mS1PT1001 – 130 °C
EICDC/010 – 200 µS0.1NTC 10K1 – 130 °C
EICDCPT/010 – 200 µS0.1PT1001 – 130 °C
EICDC/0010 – 20 µS0.01NTC 10K1 – 130 °C
EICDCPT/0010 – 20 µS0.01PT1001 – 130 °C
EICDCHPT/10 – 20 mS1PT1001 – 200 °C
EICDCHPT/010 – 200 µS0.1PT1001 – 200 °C
EICDCHPT/0010 – 20 µS0.01PT1001 – 200 °C

Operating pressure 15 bar.

Amperometric cells – Free chlorine
SCL3N/0.5SCL3N/2SCL3N/20SCL18/0.5SCL18/2SCL18/20SCL3S/20
Measuring range0 – 0.5 mg/l0 – 2 mg/l0 – 20 mg/l0 – 0.5 mg/l0 – 2 mg/l0 – 20 mg/l0 – 20 mg/l
Resolution0.0010.0010.010.0010.0010.010.01
Free chlorineInorganicInorganicInorganicInorganicInorganicInorganicOrganic and inorganic
WaterFreshFreshFreshFreshFreshFreshFresh or salt
Electrodes2223332
Selective membrane●●●–––●
Automatic compensationpH and temperaturepH and temperaturepH and temperaturepH and temperaturepH and temperaturepH and temperatureTemperature
Self-cleaning–––●●●–
Operating pH5 – 9.55 – 9.55 – 9.55 – 95 – 95 – 95.5 – 9.5
Operating temperature1 – 40 °C1 – 40 °C1 – 40 °C5 – 70 °C5 – 70 °C5 – 70 °C5 – 45 °C
Operating pressure1 bar1 bar1 bar8 bar8 bar8 bar1 bar
Water flow30 l/h30 l/h30 l/h40 l/h40 l/h40 l/h30 l/h
Amperometric cells – Chlorine dioxide
SCL2/0.5SCL2/2SCL2/20SCL17/0.5SCL17/2SCL17/20
Measuring range0 – 0.5 mg/l0 – 2 mg/l0 – 20 mg/l0 – 0.5 mg/l0 – 2 mg/l0 – 20 mg/l
Resolution0.0010.0010.010.0010.0010.01
Electrodes222333
Selective membrane●●●–––
Self-cleaning–––●●●
Operating pH4 – 114 – 114 – 115 – 95 – 95 – 9
Operating temperature1 – 40 °C1 – 40 °C1 – 40 °C5 – 70 °C5 – 70 °C5 – 70 °C
Operating pressure1 bar1 bar1 bar8 bar8 bar8 bar
Water flow30 l/h30 l/h30 l/h40 l/h40 l/h40 l/h

Automatic temperature compensation on all models.

Amperometric cells – Other oxidants
SCL8/2SCL8/20SBR/20SCL9SCL11/200SCL11/2000SCL10SCT
MeasurementTotal chlorineTotal chlorineBromineHydrogen peroxidePeracetic acidPeracetic acidOzoneChlorites
Measuring range0 – 2 mg/l0 – 20 mg/l0 – 20 mg/l0 – 200 mg/l0 – 200 mg/l0 – 2,000 mg/l0 – 2 mg/l
0 – 20 mg/l
0 – 2 mg/l
Resolution0.0010.010.010.10.110.001
0.01
0.001
Operating pH4 – 124 – 126.5 – 9.51 – 111 – 91 – 92 – 115.5 – 9.5
Operating pressure1 bar1 bar0.5 bar1 bar1 bar1 bar1 bar1 bar

All models: 2 electrodes, selective membrane, automatic temperature compensation, operating temperature 1 – 40 °C, water flow 30 l/h.

Temperature probes
ETENTCETEPT
Measuring range0 – 100 °C0 – 100 °C
Resolution0.10.1
SensorNTC 10 kΩPT100
Pressure10 bar10 bar
BodyPVDFPVDF
Thread1/2"1/2"
Operation

Measuring principle of the closed amperometric cell

The cell consists of an electronic section and a galvanic section.

Learn more: Redox, open amperometric cell and closed amperometric cell →
1

Selective membrane

The measuring electrodes are protected from direct contact with the water by a semi-permeable membrane: only the specific oxidant is measured, without interference from other substances that could alter the measurement.

2

Galvanic measurement

The electrodes of the galvanic section detect the electric current generated by the dissociation of the oxidant.

3

Compensation and signal

The cell electronics compensate the reading for temperature (and, where applicable, pH) and send the signal to the controller, which shows the concentration in mg/l on the display.

Technical data

Technical data

Each controller measures a single parameter, chosen when ordering; the code prefix identifies the parameter. For chlorine and the other oxidants the range depends on the amperometric cell used.

Technical specifications

FeatureDIN Digital
MountingDIN rail, 6 modules
Measuring channels1
Control outputs2 volt-free contacts, ON/OFF or proportional
Current outputProgrammable 0-4/20 mA, galvanically isolated, maximum load 350 Ω
InputsFlow sensor
Temperature compensationNTC 10K probe
Delay for probe polarisationProgrammable
Connection of several controllersMaster/Slave
Settings protectionPassword
DisplayBacklit LCD display
Communication–
Power supply24, 115 or 230 VAC, 50/60 Hz; 24 VDC
Average power consumption4 W
Protection ratingIP40
HousingABS
Ambient temperature0 – 50 °C
Relative humidity0 – 95 %, non-condensing

Versions and code prefixes

ParameterPrefix
pHPHDIN
RedoxRHDIN
ConductivityCDDIN
Free chlorine and chlorine dioxideCLDIN
OzoneO3DIN
TemperatureTEMPDI

In the CLDIN model the measured parameter depends on the amperometric cell connected.

Parameters

ParameterRangeResolution
pH0 – 140.01 pH
Redox−1,000 / +1,000 mV1 mV
ConductivityAccording to the probe, up to 0 – 300 mS–
Free chlorineClosed amperometric cell with membrane0.001 mg/l
Chlorine dioxideClosed amperometric cell with membrane0.001 mg/l
Ozone0 – 2 / 0 – 20 mg/l0.001 / 0.01 mg/l
Temperature0 – 100 °C0.1 °C

Free chlorine: pH and temperature compensation; maintenance-free electronic section and regenerable galvanic section.

Complete systems

Complete systems with DIN Digital

The controller is the core of the measuring and dosing system: the system page gives the composition, the installation diagram and the installation.

Panel-mounted system with DIN Digital

Measuring and dosing systemsPanel-mounted system with DIN Digital

Controller for installation in the electrical panel to drive dosing pumps or motorised valves according to the set points, with flow sensor, probe holder and filter.

The system →

For plants with special requirements, the system is defined on the basis of the characteristics of the plant and of the electrical panel: contact us.

Choosing the controller

Tell us the parameters to be measured and the characteristics of the electrical panel: we will propose the most suitable controller, probes and pumps.

Contact

Tell us about your plant

Call or write to us: a technician will reply with a tailored proposal of controllers, pumps, probes and accessories.

What do you need?
Please enter your name.
Please enter a valid email address.
Please enter your message.

Describe your plant: type, water volume or flow rate, parameters to be controlled.

You must accept the privacy notice to continue.