DIN Digital controller
Single-channel DIN-rail controller, 6 modules, with two ON/OFF or proportional volt-free contact outputs and one programmable 0-4/20 mA output.
DIN Digital →The system integrates measurement and control into the electrical panel of the plant with the DIN Digital controller, mounted on a DIN rail. The controller measures one parameter, chosen at the time of ordering among pH, Redox, conductivity, free chlorine, chlorine dioxide, ozone and temperature, and according to the set points it drives dosing pumps, including those already installed, motorised valves or the ozone generator.
The controller is completed by the probe of the parameter, the probe holder, the dosing pumps and the shut-off accessories of the plant.
Single-channel DIN-rail controller, 6 modules, with two ON/OFF or proportional volt-free contact outputs and one programmable 0-4/20 mA output.
DIN Digital →
pH or Redox electrode, contacting conductivity probe, amperometric cell for free chlorine, chlorine dioxide or ozone, or temperature probe.
Electrodes and probes →
Probe holder connected in a bypass line to the circuit, with 5" filter with washable 60 µm PET cartridges or 100 µm wound cartridges (maximum 5 bar).
Probe holders →
Flow rate and back pressure defined at the time of ordering, wetted parts in PVDF, PP, PVC or stainless steel. Supplied with a pre-calibrated injection valve and a magnetic level probe with foot suction pipe, which stops the pump when the chemical runs out.
Dosing pumps →
Installed on the pump delivery, it checks the passage of the liquid: in the event of a fault the pump performs automatic re-priming and recovers the missed injections; if the anomaly persists, it is also signalled remotely.
Flow sensor →
Connected to a set-point-controlled volt-free contact output, they shut off the water inlet or outlet according to the measured value.
The set points of the parameter to be controlled are entered; the controller drives the connected equipment automatically and continuously.
The probe, installed in a probe holder in a bypass line, in line or immersed, continuously detects the parameter; the display shows the measured value, the set points and the proportional band. The programmable delay waits for the probe to polarise before starting control.
The two volt-free contact outputs control the pumps in ON/OFF or proportional mode, for example for acid and base, or for the same chemical at two injection points; the 0-4/20 mA output retransmits the measurement or drives a pump directly over the proportional band.
The volt-free contact outputs control pumps already installed, motorised valves that shut off the water inlet or outlet, or the start and stop of the ozone generator, when the set points are reached.
The flow sensor input allows dosing to be suspended when no water flows through the probe holder and the measurement is not representative.
The probes, the flow sensor and the controlled loads are connected to the terminal board of the controller.
The controller has no dedicated alarm output: alarm conditions are shown on the display.
The controller is mounted on a DIN rail, 6 modules, in the electrical panel of the plant, next to the other control devices; ABS housing, IP40 protection, 24, 115 or 230 VAC or 24 VDC power supply.

The controller is installed in the existing panel or in its own enclosure with transparent cover, ready for connection; several controllers can be connected to each other in Master/Slave mode.
The sample water is taken with a T-fitting on the pipe, flows through the filter and the probe holder and returns to the circuit or to drain.
Probe holders →The panel-mounted system is used when measurement and control must be part of the electrical panel of the plant, together with the other controls.
In drinking water treatment and distribution plants, the controller regulates pH or the disinfectant from the plant panel.
Learn more: drinking water →
In industrial circuits, the volt-free contact outputs control the dosing pumps and motorised valves already present in the plant.
Learn more: industrial water →
In wastewater treatment plants, the controller is integrated into the control panel and retransmits the measurement through the 0-4/20 mA output.
Learn more: wastewater →For each parameter measured by the DIN Digital controller a complete system is available, with the probe, the composition and the applications.
pH electrode and dosing pumps for acid or alkali, driven according to the measured pH.
The system →
Redox electrode and dosing pump for hypochlorite or another disinfectant, driven according to the measured potential.
The system →
Contacting probe; the controller drives dosing pumps and motorised inlet and drain valves.
The system →
Closed amperometric cell and hypochlorite dosing pump, driven according to the measured free chlorine.
The system →
SCL2 cell for cold water or SCL17 cell for domestic hot water, and chlorine dioxide dosing pump.
The system →
SCL10 closed amperometric cell; the controller starts and stops the ozone generator.
The system →
Versions and code prefixes, parameters, measuring ranges, inputs, outputs and technical characteristics are given on the controller page.
Accessories available on request to adapt the system to the requirements of the installation.
PE tanks for the chemical, with safety bund.
Details →
Injects the chemical into the centre of the pipe.
Details →
Pressure, safety and anti-siphon functions combined in a single valve.
Details →
Ensures the chemical is mixed with the water and protects the pipe from direct contact with it.
Details →
Attenuates the pulsations generated by the dosing pump.
Details →Tell us the parameter to be controlled, the characteristics of the panel and the equipment to be driven: we will propose the most suitable probe, pumps and accessories.
Call or write to us: a technician will reply with a tailored proposal of controllers, pumps, probes and accessories.