DIN Digital controller · CLDIN
Single-channel DIN-rail controller, 6 modules, with two ON/OFF or proportional volt-free contact outputs and one programmable 0-4/20 mA output.
DIN Digital →The system continuously measures the residual free chlorine with a closed amperometric cell and the DIN Digital controller, mounted on a DIN rail in the electrical panel of the plant; according to the set points it drives the hypochlorite dosing pump, including one already installed, and the motorised valves. The 0-4/20 mA output retransmits the measurement or directly drives a dosing pump with current input.
The controller is completed by the amperometric cell, the probe holder with the filter, the hypochlorite dosing pump and the shut-off accessories of the plant.
Single-channel DIN-rail controller, 6 modules, with two ON/OFF or proportional volt-free contact outputs and one programmable 0-4/20 mA output.
DIN Digital →
The electrodes are protected by a selective membrane that excludes contaminants from the measurement; with automatic pH and temperature compensation the measurement remains reliable. The galvanic part, the only one subject to wear, can be regenerated without replacing the electronic part.
SCL cells →
Probe holder connected in a bypass line to the circuit, with 5" filter with washable 60 µm PET cartridges or 100 µm wound cartridges (maximum 5 bar).
Probe holders →
Flow rate and back pressure defined at the time of ordering, wetted parts in PVDF, PP, PVC or stainless steel. Supplied with a pre-calibrated injection valve and a magnetic level probe with foot suction pipe, which stops the pump when the chemical runs out.
Dosing pumps →
Installed on the pump delivery, it checks the passage of the liquid: in the event of a fault the pump performs automatic re-priming and recovers the missed injections; if the anomaly persists, it is also signalled remotely.
Flow sensor →
Connected to a set-point-controlled volt-free contact output, they shut off the water inlet or outlet according to the measured value.
The set points of the parameter to be controlled are entered; the controller drives the connected equipment automatically and continuously.
The sample water flows through the filter and the probe holder in a bypass line, where the amperometric cell measures the free chlorine; the display shows the measured value, the set points and the proportional band. The programmable delay waits for the probe to polarise before starting control.
The two volt-free contact outputs control the pumps in ON/OFF or proportional mode, for example for acid and base, or for the same chemical at two injection points; the 0-4/20 mA output retransmits the measurement or drives a pump directly over the proportional band.
The volt-free contact outputs control pumps already installed, motorised valves that shut off the water inlet or outlet, or the start and stop of the ozone generator, when the set points are reached.
The flow sensor input allows dosing to be suspended when no water flows through the probe holder and the measurement is not representative.
The probes, the flow sensor and the controlled loads are connected to the terminal board of the controller.
The controller has no dedicated alarm output: alarm conditions are shown on the display.
The controller is mounted on a DIN rail, 6 modules, in the electrical panel of the plant, next to the other control devices; ABS housing, IP40 protection, 24, 115 or 230 VAC or 24 VDC power supply.

The controller is installed in the existing panel or in its own enclosure with transparent cover, ready for connection; several controllers can be connected to each other in Master/Slave mode.
The sample water is taken with a T-fitting on the pipe, flows through the filter and the probe holder and returns to the circuit or to drain.
Probe holders →The panel-mounted system is used when measurement and control must be part of the electrical panel of the plant, together with the other controls.
The system controls the free chlorine residual in water from private wells and springs and from public water supply networks, and in storage tanks.
In fire-fighting water reserves, free chlorine is kept at the set point by injecting hypochlorite into the make-up line of the tank.
In water used in industrial processes, free chlorine remains at the set value as the flow rate and load vary.
Learn more: industrial water →
Versions and code prefixes, parameters, measuring ranges, inputs, outputs and technical characteristics are given on the controller page.
Accessories available on request to adapt the system to the requirements of the installation.
PE tanks for the chemical, with safety bund.
Details →
Injects the chemical into the centre of the pipe.
Details →
Pressure, safety and anti-siphon functions combined in a single valve.
Details →
Ensures the chemical is mixed with the water and protects the pipe from direct contact with it.
Details →
Attenuates the pulsations generated by the dosing pump.
Details →Tell us the parameter to be controlled, the characteristics of the panel and the equipment to be driven: we will propose the most suitable probe, pumps and accessories.
Call or write to us: a technician will reply with a tailored proposal of controllers, pumps, probes and accessories.