Measuring and dosing systems

Hydrogen peroxide

The system continuously measures the concentration of hydrogen peroxide in the water and controls the dosing pump in proportion to the measured value, until the set point is reached: the concentration remains constant even when the flow rate or the oxidant demand of the water changes.

  • Hydrogen peroxide in mg/l
  • SCL9 closed amperometric cell
  • Dosing proportional to the residual
LDsCL system for hydrogen peroxide on a panel with dosing pump, filter and probe holder
Systemhydrogen peroxide
SCL9 closed amperometric cell for hydrogen peroxide
SCL9 cell
Components

Basic components

The system is supplied pre-assembled on a panel, ready to be connected in a bypass line to the circuit of the water to be treated.

LDsCL controller

LDsCL controller

It acquires the measurement from the cell and controls the dosing pump in proportion to the deviation from the set point.

LDsCL for hydrogen peroxide →
SCL9 closed amperometric cell

SCL9 closed amperometric cell

The selective membrane allows hydrogen peroxide alone to be measured; temperature is compensated automatically.

SCL9 cell →
PEF flow-through probe holder

Flow-through probe holder

It holds the cell in the flow of sample water, with flow rate adjustment and flow control, which stops dosing when there is no circulation.

Probe holders →
NFIL filter

Sample water filter

Installed upstream of the probe holder, it retains the impurities that would foul the membrane of the cell.

NFIL filter →
VMS MF dosing pump

Dosing pump

Solenoid diaphragm pump, with flow rate and back pressure defined when ordering, controlled by the controller.

Dosing pumps →
Injection lance

Injection lance

It introduces the product into the centre of the pipe, improving mixing; it can be withdrawn with the pipe under pressure.

Lances →
Operation

Operation

The concentration of hydrogen peroxide to be maintained in the water (set point) is entered; the system maintains it automatically and continuously.

Layout of the system on a storage tank: LDsCL controller, SCL9 amperometric cell fed by a sampling pump, dosing pump with the hydrogen peroxide tank, chemical injection and booster pump
1

Continuous measurement

The sample water flows through the filter and the probe holder, where the SCL9 cell measures the hydrogen peroxide; the water then returns to the circuit or the tank.

2

Proportional dosing

When the concentration falls below the set point, the controller starts the pump at a frequency that increases the further the reading is from the set point; once the set point is reached, the pump stops.

3

Flow control

When there is no flow in the probe holder the measurement is not representative: dosing is suspended until circulation is restored.

4

Alarms

The controller signals out-of-range readings, a faulty probe, the product level and the absence of flow.

By adding a pulse-output water meter, dosing can also be made proportional to the volume of water treated; the controller can also drive solenoid valves or other equipment according to the measured value.

Applications

Where it is used

Hydrogen peroxide, or active oxygen, is an oxidant that does not produce the by-products of chlorine; the system keeps its concentration constant in cold water.

Wastewater

Wastewater

Dosing is adjusted to the concentration actually measured in municipal and industrial wastewater.

Learn more: wastewater →
Cooling towers

Cooling towers

As an oxidising biocide, hydrogen peroxide is maintained at a residual that can be measured continuously with the amperometric cell.

Learn more: cooling towers →
Private swimming pools

Private swimming pools

As an alternative to chlorine, hydrogen peroxide (active oxygen) is measured with the same SCL9 cell and combined with pH control.

Systems for private swimming pools →
Installation

Panel installation in a bypass line

Controller, dosing pump, filter and probe holder are mounted on a panel. The panel is connected to the circuit in a bypass line: the sample water is taken from the pipe or the tank, flows through the probe holder and returns to the storage tank, to the suction of the recirculation pumps or to drain.

LDsCL system on a panel with dosing pump, filter and probe holder

System on a panel

The controller and the pump are mounted in the upper part of the panel, the filter and the probe holder in the lower part.

Diagram of the bypass connection of the PEF flow-through probe holder

Probe holder connection

The sample is taken with a T-fitting on the pipe carrying the water to be analysed.

Probe holders →
Optional extras

Optional accessories

Accessories available on request to adapt the system to the requirements of the installation.

Tank

Tank

PE tanks for the chemical, with safety bund.

Details →
Pulse-output water meter

Pulse-output water meter

Enables dosing proportional to the volume of water actually treated.

Details →
Flow sensor

Flow sensor

Installed on the pump delivery line, it verifies that dosing actually takes place.

Details →
Multifunction valve

Multifunction valve

Pressure, safety and anti-siphon functions combined in a single valve.

Details →
Static mixer

Static mixer

Ensures the chemical is mixed with the water and protects the pipe from direct contact with it.

Details →
Pulsation dampener

Pulsation dampener

Attenuates the pulsations generated by the dosing pump.

Details →
Solenoid valve

Solenoid valve

Operated by the controller according to the measured value.

The controller

The LDsCL controller for hydrogen peroxide

LDsCL system for hydrogen peroxide pre-assembled on a panel

LDsCL for hydrogen peroxide

Measuring range, resolution, characteristics of the SCL9 cell, inputs, outputs and connections are given in the controller data sheet.

Remote control

System remote control

The controllers support two-way remote access (read and write) through the web portal from a PC, tablet or smartphone: measurements can be viewed, set points, dosing and alarms changed, alarms received and logs downloaded. Alternatively, they can be integrated into your PLC via Modbus.

Ethernet

Connection to the web portal via network cable: measurements, set points, dosing and alarms accessible from a PC, tablet or smartphone.

Optional (one only)

Wi-Fi

Wireless connection to the web portal, with the same functions as the cable connection.

Optional (one only)

4G

Connection via the 4G network for installations without a local network, with alarm notification by SMS or e-mail.

Optional (one only)
NIMBUS web portal for remote control of the systemsWeb portalPC, tablet and smartphone

Modbus RTU

Integration into your PLC via serial port.

Standard (BASIC), optional (PLUS)

0-4/20 mA current loop output

Current signal proportional to the measured value, for remote monitoring or for controlling pumps and other instrumentation.

3 standard (PLUS), 2 on request (BASIC)

USB port

Download of the logged data to a USB memory stick, for archiving and analysis with a spreadsheet.

Optional

One communication type at a time: Ethernet, Wi-Fi, 4G or Modbus RTU (built into the BASIC versions, optional on the PLUS versions). 0-4/20 mA current loop outputs standard on the PLUS versions, optional on the BASIC versions; meter input on the PLUS versions only.

The NIMBUS portal

A single account brings together all registered installations, each with its own devices: the web portal, free of charge and with no subscription, can be accessed from a PC, Mac, tablet or smartphone and allows every parameter to be both viewed and changed, with an encrypted connection and protected access.

The NIMBUS portal on monitor, laptop, tablet and smartphone

Overview

On a single screen: probe readings, chemical levels, pump activation thresholds and active alarms, with the status of installations and devices (normal, warning, alarm, standby, not connected).

Installation map

Installations appear on an interactive map with their status and open with a click; for each one, the local weather conditions and temperature are also shown.

History and charts

Archive of measurements and alarms, available for consultation at any time with charts and numerical reports exportable in Excel format.

Alarms and notifications

Alarm thresholds for readings, dosing, faulty probe and out-of-range readings, with notification by e-mail or SMS depending on the communication system; a warning is also issued when an installation remains disconnected beyond the set time.

Set points and dosing

Remote modification of the set points, of the dosing pump activation thresholds and of the corresponding hourly flow rate.

Inputs and outputs

Status of relays, pulse outputs, digital inputs and current outputs, with the name assigned to each connection.

Maintenance calendar

Tasks are scheduled by installation or by device and assigned to technicians; a reminder is sent by e-mail two days before the due date. Each task is shown as scheduled, due, overdue or completed.

Team and permissions

The main account has full access and creates the technicians’ accounts, each enabled only for the assigned installations and devices; the last login and activity of each technician are visible.

Reports and activity log

Reports on devices, tasks and technicians, downloadable in PDF or CSV with the customer’s logo; the log keeps the history of operations and disconnections.

Customisation

Logo, main colour and light or dark theme; the tiles on the main screen can be rearranged by dragging them. Two installations can be displayed side by side for comparison.

Guided registration

Each device is added through a guided procedure: the model is recognised automatically and associated with the installation, together with the technician to be contacted.

PLC integration

As an alternative to the portal, the Modbus RTU port allows integration into the plant supervision system.

NIMBUS portal: Real-time readings, counters and timers
Real-time readings, counters and timers
NIMBUS portal: Free chlorine and temperature trends
Free chlorine and temperature trends
NIMBUS portal: Set point and operating mode of each channel
Set point and operating mode of each channel
NIMBUS portal: Status of relays, pulses, inputs and mA outputs
Status of relays, pulses, inputs and mA outputs

Technical advice

Describe your plant, the water flow rate and the hydrogen peroxide concentration to be maintained: we will size the controller, pump and accessories.

Contact

Tell us about your plant

Call or write to us: a technician will reply with a tailored proposal of controllers, pumps, probes and accessories.

What do you need?
Please enter your name.
Please enter a valid email address.
Please enter your message.

Describe your plant: type, water volume or flow rate, parameters to be controlled.

You must accept the privacy notice to continue.