Measuring and dosing systems

Two amperometric cells

The system continuously measures two oxidants with two amperometric cells connected to a single dual-channel controller. The typical combinations are free chlorine with total chlorine, from which combined chlorine is obtained by difference, and chlorine dioxide with chlorites, the by-products of its reaction: a single controller controls the dosing of the disinfectant and monitors its effects.

  • Two amperometric cells
  • Free chlorine and total chlorine
  • Chlorine dioxide and chlorites
  • Out-of-range alarm for each cell
Panel with LD controller, dosing pump, filter and amperometric cell in the flow-through probe holder
Two cellson a panel
Closed SCL8 amperometric cell for total chlorine
SCL8 cell
How it works

Two oxidants, one controller

The two cells, installed in flow-through probe holders in by-pass on the plant, analyse the same water sample; the controller displays the two concentrations and the temperature and controls each channel with its own set points.

1

First channel

It measures the disinfectant, free chlorine or chlorine dioxide, and drives the dosing pump in ON/OFF, proportional or PWM mode.

2

Second channel

It measures total chlorine or chlorites and, with its own set points, drives the assigned relay or proportional output.

3

Out of range

The reading range is set for each cell: outside it the controller interrupts dosing and signals the alarm.

Combinations

The two combinations

Chlorine dioxide and chlorites

In water disinfected with chlorine dioxide the first channel controls its dosing, the second measures chlorites with the SCT cell, whose membrane excludes free chlorine, chlorine dioxide and chlorates: when the threshold is exceeded the controller generates an alarm and stops chlorine dioxide dosing.

Components

Basic components

The system consists of the dual-channel controller, the two cells with the flow-through probe holders, the disinfectant dosing pump and the injection accessories.

LD dual-channel controller

LDCLCL controller

It reads the two cells and the PT100 temperature probe and drives three proportional pulse outputs, two relay outputs, the alarm output and the flocculant output.

LD dual-channel controllers →
Closed SCL amperometric cells

Amperometric cells

Closed amperometric cells with selective membrane and automatic temperature compensation, one for each oxidant: SCL8 for total chlorine, SCT for chlorites.

Amperometric cells →
PEF1-E flow-through probe holder

Flow-through probe holder

In PMMA, with sample flow regulation and flow sensor, which stops dosing when there is no circulation; upstream a filter with washable cartridge.

Probe holders →
VMS MF dosing pump

Dosing pump

Solenoid diaphragm pump for the disinfectant, with flow rate and back pressure defined when ordering, driven by the controller.

Dosing pumps →
Operation

Checks and alarms

Levels

Three level inputs monitor the product tanks and signal depletion.

Flow and stand-by

The flow sensor and the stand-by input suspend dosing when no water circulates in the probe holder or the plant is stopped.

0-4/20 mA outputs

The current outputs transmit the two concentrations and the temperature to a supervisory system.

Applications

Fields of application

Drinking water

Drinking water

In water disinfected with chlorine dioxide the system controls its dosing and continuously checks the chlorite concentration.

Drinking water systems →
Domestic water circuits

Domestic water circuits

In domestic water circuits treated with chlorine dioxide, chlorite monitoring complements the measurement of the disinfectant.

Anti-Legionella →
The controller

LD dual-channel controllers

LDpHCL system pre-assembled on a panel with two dosing pumps, filter and probe holder

LD Dual Parameter

Available parameter combinations, BASIC and PLUS versions, display and connections of the dual-channel controllers are given on the series page.

Remote control

System remote control

The controllers support two-way remote access (read and write) through the web portal from a PC, tablet or smartphone: measurements can be viewed, set points, dosing and alarms changed, alarms received and logs downloaded. Alternatively, they can be integrated into your PLC via Modbus.

Ethernet

Connection to the web portal via network cable: measurements, set points, dosing and alarms accessible from a PC, tablet or smartphone.

Optional (one only)

Wi-Fi

Wireless connection to the web portal, with the same functions as the cable connection.

Optional (one only)

4G

Connection via the 4G network for installations without a local network, with alarm notification by SMS or e-mail.

Optional (one only)
NIMBUS web portal for remote control of the systemsWeb portalPC, tablet and smartphone

Modbus RTU

Integration into your PLC via serial port.

Standard (BASIC), optional (PLUS)

0-4/20 mA current loop output

Current signal proportional to the measured value, for remote monitoring or for controlling pumps and other instrumentation.

Optional (3 outputs)

USB port

Download of the logged data to a USB memory stick, for archiving and analysis with a spreadsheet.

Optional

One communication type at a time: Ethernet, Wi-Fi, 4G or Modbus RTU (built into the BASIC versions, optional on the PLUS versions). 0-4/20 mA current loop outputs optional; meter input on the PLUS versions only.

The NIMBUS portal

A single account brings together all registered installations, each with its own devices: the web portal, free of charge and with no subscription, can be accessed from a PC, Mac, tablet or smartphone and allows every parameter to be both viewed and changed, with an encrypted connection and protected access.

The NIMBUS portal on monitor, laptop, tablet and smartphone

Overview

On a single screen: probe readings, chemical levels, pump activation thresholds and active alarms, with the status of installations and devices (normal, warning, alarm, standby, not connected).

Installation map

Installations appear on an interactive map with their status and open with a click; for each one, the local weather conditions and temperature are also shown.

History and charts

Archive of measurements and alarms, available for consultation at any time with charts and numerical reports exportable in Excel format.

Alarms and notifications

Alarm thresholds for readings, dosing, faulty probe and out-of-range readings, with notification by e-mail or SMS depending on the communication system; a warning is also issued when an installation remains disconnected beyond the set time.

Set points and dosing

Remote modification of the set points, of the dosing pump activation thresholds and of the corresponding hourly flow rate.

Inputs and outputs

Status of relays, pulse outputs, digital inputs and current outputs, with the name assigned to each connection.

Maintenance calendar

Tasks are scheduled by installation or by device and assigned to technicians; a reminder is sent by e-mail two days before the due date. Each task is shown as scheduled, due, overdue or completed.

Team and permissions

The main account has full access and creates the technicians’ accounts, each enabled only for the assigned installations and devices; the last login and activity of each technician are visible.

Reports and activity log

Reports on devices, tasks and technicians, downloadable in PDF or CSV with the customer’s logo; the log keeps the history of operations and disconnections.

Customisation

Logo, main colour and light or dark theme; the tiles on the main screen can be rearranged by dragging them. Two installations can be displayed side by side for comparison.

Guided registration

Each device is added through a guided procedure: the model is recognised automatically and associated with the installation, together with the technician to be contacted.

PLC integration

As an alternative to the portal, the Modbus RTU port allows integration into the plant supervision system.

NIMBUS portal: Real-time readings, counters and timers
Real-time readings, counters and timers
NIMBUS portal: Free chlorine and temperature trends
Free chlorine and temperature trends
NIMBUS portal: Set point and operating mode of each channel
Set point and operating mode of each channel
NIMBUS portal: Status of relays, pulses, inputs and mA outputs
Status of relays, pulses, inputs and mA outputs

Technical advice

Tell us the disinfectant used and the measurements to be monitored: we will propose the most suitable cells, pumps and accessories.

Contact

Tell us about your plant

Call or write to us: a technician will reply with a tailored proposal of controllers, pumps, probes and accessories.

What do you need?
Please enter your name.
Please enter a valid email address.
Please enter your message.

Describe your plant: type, water volume or flow rate, parameters to be controlled.

You must accept the privacy notice to continue.