In industrial processes, water must be conditioned according to production requirements: the systems continuously measure pH, conductivity and the concentration of the disinfectant or oxidant, and control the dosing pumps in proportion to the measured value, up to the set point.

  • pH and conductivity
  • Redox, chlorine and oxidants
  • One, two or more parameters
Process water
Process water
The sector

Complex water processes

In industrial plants, water is used for cooling, producing steam, washing and as an ingredient, and is eventually discharged or reused: each use has its own treatment and its own parameters to control.

Industrial plant

Efficiency and costs

Precise and constant dosing reduces chemical waste, maintains plant performance and supports continuous processes, with higher productivity and lower operating costs.

Conditioning

Process water is conditioned according to production requirements.

Proportional dosing

The chemicals are dosed in proportion to the measured value, up to the set point.

Before discharge

Pollutants are controlled before discharge, reducing the environmental impact.

Requirements

Requirements

1

pH

The pH of process water is controlled by dosing acid or base in proportion to the measured value.

2

Dissolved salts

Conductivity indicates the amount of dissolved salts and controls the dosing of chemicals or the inlet and drain solenoid valves.

3

Disinfectants and oxidants

Chlorine, hydrogen peroxide and peracetic acid remain at the set concentration as the flow rate and load vary.

4

Several parameters

Dual-channel controllers and the Centurio PRO measure several variables and control all the pumps of the plant.

Our

Systems for process water

Each system has its own page with the diagram, the components and the operation.

LDspH
pH control

LDspH

The LDspH controller continuously measures the pH of the process water and controls one or more dosing pumps, which inject acid or base in proportion to the measured value up to the pH required by production.

Advantages

  • The same controller manages the dosing of both acid and base.
  • The electrode is installed in by-pass, in line or immersed.
LDsPN PLUS
Batch neutralisation

LDsPN PLUS

The LDsPN PLUS controller neutralises process water collected in a tank in batches: it controls filling, the mixer, the acid and base pumps and, after the reaction time, draining.

Advantages

  • Neutralisation to the set pH or alkaline precipitation followed by neutralisation.
  • The cycle is repeated at each activation signal.
LDsCD
Conductivity

LDsCD

The LDsCD controller measures the conductivity of the process water, which depends on the amount of dissolved salts, and according to the set points controls the dosing pumps or the inlet and drain solenoid valves.

Advantages

  • The system is supplied with contacting or inductive probes.
  • Temperature is compensated with the PT100 probe.
LDsRh
Redox potential in mV

LDsRh

The LDsRh controller measures the Redox potential of the process water, which indicates its disinfecting power, and adjusts the disinfectant dosing to the variations in the pollutant load, up to the set point.

Advantages

  • It is the most economical solution for linking disinfectant dosing to a continuous measurement.

Limitations

  • Indirect measurement: it reads mV, not mg/l of disinfectant.
LDsCL for free chlorine
LDsCL · free chlorine in mg/l

Free chlorine

The LDsCL controller measures the free chlorine residual with an amperometric cell and controls the hypochlorite pump in proportion to the deviation from the set point: in process water the residual remains at the set value as the flow rate and load vary.

Advantages

  • The amperometric cell measures free chlorine in mg/l.
  • The closed amperometric cell automatically compensates for pH and temperature.
LDsCL for hydrogen peroxide
LDsCL · SCL9 cell

Hydrogen peroxide

The LDsCL controller with the SCL9 closed amperometric cell continuously measures the hydrogen peroxide concentration and controls the dosing pump in proportion to the measured value: in process water the oxidant concentration remains stable as the load varies.

Advantages

  • Hydrogen peroxide is an oxidant that does not produce the by-products of chlorine.
LDsCL for peracetic acid
LDsCL · SCL11 cell

Peracetic acid

The LDsCL controller with the SCL11 closed amperometric cell continuously measures the peracetic acid concentration in process and washing water and controls the dosing pump, keeping the concentration within the specified values at every stage of processing.

Advantages

  • The SCL11 cell is available with a 0 – 200 mg/l or a 0 – 2,000 mg/l range.
  • Continuous measurement documents the disinfectant concentration.
LD dual-channel
Two parameters

LD dual-channel

The LD dual-channel controller measures two parameters of the process water, in addition to temperature, and controls dosing pumps, solenoid valves or other equipment with two independent control loops, one for each channel.

Advantages

  • A single controller manages two parameters with separate set points.
  • The system is supplied on a panel, in a cabinet or on a skid.
Centurio PRO
Up to 10 channels

Centurio PRO

The Centurio PRO measures all the parameters of the plant, up to 10 channels, and controls all the dosing pumps, with dosing proportional to the measurement, residual, volumetric or timed: a single controller for processes that require several variables to be controlled.

Advantages

  • The 0-4/20 mA inputs also acquire third-party probes and other process instruments.
  • The touch screen and remote control allow the plant to be monitored from a distance.
Learn more

Learn more

Remote control

System remote control

The controllers support two-way remote access (read and write) through the web portal from a PC, tablet or smartphone: measurements can be viewed, set points, dosing and alarms changed, alarms received and logs downloaded. Alternatively, they can be integrated into your PLC via Modbus.

Ethernet

Connection to the web portal via network cable: measurements, set points, dosing and alarms accessible from a PC, tablet or smartphone.

Wi-Fi

Wireless connection to the web portal, with the same functions as the cable connection.

4G

Connection via the 4G network for installations without a local network, with alarm notification by SMS or e-mail.

NIMBUS web portal for remote control of the systemsWeb portalPC, tablet and smartphone

Modbus RTU

Integration into your PLC via serial port.

Modbus TCP/IP

Integration into your PLC or SCADA via Ethernet network.

0-4/20 mA current loop output

Current signal proportional to the measured value, for remote monitoring or for controlling pumps and other instrumentation.

The NIMBUS portal

A single account brings together all registered installations, each with its own devices: the web portal, free of charge and with no subscription, can be accessed from a PC, Mac, tablet or smartphone and allows every parameter to be both viewed and changed, with an encrypted connection and protected access.

The NIMBUS portal on monitor, laptop, tablet and smartphone

Overview

On a single screen: probe readings, chemical levels, pump activation thresholds and active alarms, with the status of installations and devices (normal, warning, alarm, standby, not connected).

Installation map

Installations appear on an interactive map with their status and open with a click; for each one, the local weather conditions and temperature are also shown.

History and charts

Archive of measurements and alarms, available for consultation at any time with charts and numerical reports exportable in Excel format.

Alarms and notifications

Alarm thresholds for readings, dosing, faulty probe and out-of-range readings, with notification by e-mail or SMS depending on the communication system; a warning is also issued when an installation remains disconnected beyond the set time.

Set points and dosing

Remote modification of the set points, of the dosing pump activation thresholds and of the corresponding hourly flow rate.

Inputs and outputs

Status of relays, pulse outputs, digital inputs and current outputs, with the name assigned to each connection.

Maintenance calendar

Tasks are scheduled by installation or by device and assigned to technicians; a reminder is sent by e-mail two days before the due date. Each task is shown as scheduled, due, overdue or completed.

Team and permissions

The main account has full access and creates the technicians’ accounts, each enabled only for the assigned installations and devices; the last login and activity of each technician are visible.

Reports and activity log

Reports on devices, tasks and technicians, downloadable in PDF or CSV with the customer’s logo; the log keeps the history of operations and disconnections.

Customisation

Logo, main colour and light or dark theme; the tiles on the main screen can be rearranged by dragging them. Two installations can be displayed side by side for comparison.

Guided registration

Each device is added through a guided procedure: the model is recognised automatically and associated with the installation, together with the technician to be contacted.

PLC integration

As an alternative to the portal, the Modbus RTU or TCP/IP port allows integration into the plant supervision system.

NIMBUS portal: Real-time readings, counters and timers
Real-time readings, counters and timers
NIMBUS portal: Free chlorine and temperature trends
Free chlorine and temperature trends
NIMBUS portal: Set point and operating mode of each channel
Set point and operating mode of each channel
NIMBUS portal: Status of relays, pulses, inputs and mA outputs
Status of relays, pulses, inputs and mA outputs

Technical advice

Describe the process, the water flow rate and the parameters to be controlled: we will propose the most suitable system.

Contact

Tell us about your plant

Call or write to us: a technician will reply with a tailored proposal of controllers, pumps, probes and accessories.

What do you need?
Please enter your name.
Please enter a valid email address.
Please enter your message.

Describe your plant: type, water volume or flow rate, parameters to be controlled.

You must accept the privacy notice to continue.