Skip to content
Peristaltic swimming pool dosing pump

WNpHRh

Swimming pool dosing pump with two integrated stepper motor peristaltic pumps, for the pH adjuster and for the disinfectant, controlled by the pH and Redox potential (ORP) measurements, over ranges of 0 to 14 pH and 0 to 1,000 mV. The controller also reads the temperature and compensates the pH measurement for temperature. The AUTO DOSING function is available for both parameters.

  • pH and Redox (ORP)
  • 0 – 1,000 mV range
  • AUTO DOSING for pH and Redox
  • Silent operation
WNpHRh swimming pool dosing pump for pH and Redox
12l/hMaximum flow rate
2barMaximum pressure
1–100RPMRotor speed
IP54Protection rating
The model

WNpHRh

WNpHRh swimming pool dosing pump for pH and Redox
pH and Redox

WNpHRh

With integrated pH and Redox (ORP) measuring controllers.

  • Proportional to pH
  • Proportional to Redox
  • Automatic pH dosing
  • Automatic Redox dosing
  • External constant
Compatible components
EpHS EpHSpH electrode
ERhS ERhSRedox (ORP) electrode
Operation

Dosing modes

External constant

When the run contact closes, the pump doses the set quantity of chemical.

Proportional to pH

The required pH value (SET POINT) is set: the pump measures the pH by means of a pH electrode and progressively reduces the injection frequency as the measured value approaches the set point, stopping when the SET POINT is reached.

Proportional to Redox

The required Redox potential (ORP) (SET POINT) is set: the pump measures it by means of a Redox electrode and progressively reduces the injection frequency as the measured value approaches the set point, stopping when the SET POINT is reached.

Automatic pH dosing

Once the pool volume has been set, the pump automatically adjusts dosing according to the required pH (SET POINT), measured by means of a pH electrode: the injection frequency is progressively reduced as the measured value approaches the set point, until the pump stops when the SET POINT is reached.

Automatic Redox dosing

Once the pool volume has been set, the pump automatically adjusts dosing according to the required Redox potential (ORP) (SET POINT), measured by means of a Redox electrode: the injection frequency is progressively reduced as the measured value approaches the set point, until the pump stops when the SET POINT is reached.

Technology

Stepper motor peristaltic technology

The flow rate is adjusted electronically by frequency, by varying the number of revolutions per minute of the motor. The exclusive AUTO DOSING function automatically configures system operation on the basis of the pool water volume.

Turndown ratio of the stepper motor

Stepper motor

The stepper motor and the control software deliver the product optimally with completely silent operation, a feature appreciated when dosing pH adjuster and disinfectant in swimming pools and hot tubs.

TPV peristaltic tube and pump rotorTPV peristaltic tube and pump rotor

TPV peristaltic tube

The tube is made of TPV, an elastomer compatible with most chemicals, which retains its elastic properties even after millions of compression cycles by the rollers.

Typical layout

Typical layout

The treatment system is installed in the plant room, downstream of the filter: the probes analyse a water sample and injection takes place on the delivery pipe to the pool.

Typical layout of a swimming pool installation: pool with skimmer and return inlet, filtration pump, filter, WNpHRh panel with the pH pump, the chlorine pump and the injection lines, sample filter and probe holder, make-up with water meter and motorised valve
Colour display

Colour-coded status indication

The display colour changes with the operating status, so that an alarm can be recognised even from a distance. The setting screens of this model are shown below.

Display Green

Green

Normal operation according to the set parameters, no active alarms.

Display Yellow

Yellow

Non-blocking alarm, for example waiting for an external signal.

Display Red

Red

Blocking alarm, for example the chemical in the tank running out.

Display White

White

Pump stopped by an external control signal (stand-by).

Settings from the display

pH set point
pH set point
pH and Redox (ORP)
pH and Redox (ORP)
pH and Redox set points
pH and Redox set points
Technical data

Performance and configurations

Performance depends on the peristaltic tube installed: the 1.6 × 1.6 mm tube covers the lowest flow rates, the 4.8 × 1.6 mm tube flow rates up to 12 l/h. The tube set in the controller must match the one installed, because the AUTO DOSING function takes it into account when calculating the dosage.

Peristaltic tubes

Suitable for dosing most chemicals.

Tube (mm)Max pressure (bar)Flow rate (l/h)ml/revRPM
1.6 × 1.620.018 – 1.80.31 – 100
4.8 × 1.620.12 – 1221 – 100

Technical specifications

SpecificationValue
Integrated pumps2 stepper motor peristaltic pumps, for the pH adjuster and for the disinfectant
Measuring range0 – 14 pH; 0 – 1,000 mV
Temperature reading0 – 100 °C
Rotor speed1 – 100 RPM
Maximum pressure2 bar
Maximum chemical viscosity100 cP
Delayed dosing startUp to 60 minutes
Power supply100 – 240 VAC, 50/60 Hz
Protection ratingIP54

Peristaltic pump materials

ComponentMaterial
Pump bodyPC/ABS
CoverPC
Dust bushingPEEK/PPS
Tube retainer and hose connectorsPVDF
RollerPOM (Delrin)
Long-life peristaltic tubeTPV

Power supplies

  • 100 – 240 VAC

Supplied with

  • Level probe kit with foot valve
Complete systems

Complete systems with WNpHRh

The pump, with its built-in measuring instruments, is the core of the treatment system: for each application, the system page gives the composition, the installation diagram and the installation.

WNpHRh

Swimming poolsWNpHRh

Peristaltic version of the WDpHRh: two precise stepper-motor peristaltic pumps measure and control pH and Redox potential.

The system →
WNpHRh

Fire-fighting tanksWNpHRh

The WNpHRh controller measures pH and Redox potential with the electrodes immersed in the tank and controls two integrated stepper-motor peristaltic pumps for the acid and the hypochlorite, with Wi-Fi as standard.

The system →
Technical support

Troubleshooting and error messages

In addition to dosing, the WN pumps also monitor the water: the messages mainly concern the process; in peristaltic pumps the condition of the tubes is also decisive.

Learn more: the pump does not prime and does not dose →

If the pump…

Irregular dosing, leaks or air intake
  • Peristaltic tube worn, hardened or deformedReplace the tube (see the procedure below).
  • Non-compliant tube or tube not fitted correctlyFit the tube specified for the model and check that it is properly secured.
No dosing at start-up
  • Pump not primedStop the motor, prime the pump and restart it.
  • Pressure above the rated valueStop the pump immediately and check the downstream system.

Display messages

MessageMeaningAction
LOW TANKChemical tank close to running out.Check and restore the chemical level in the tank.
NO FLOWThe flow contact has stopped the pumps.Check that there is water flow in the probe holder.
FEED LIMITMaximum dosing time exceeded without reaching the set point.Check the pump flow rate and the actual supply of chemical.
PROBE FAILProbe reading unchanged for too long: the probe is probably damaged.Check the probe, clean or recalibrate it; if the problem persists, replace it.
WAIT pHpH has priority: the second dosing waits until the pH returns to the correct values.Normal operating condition; to disable it, change the priority option.
DELAYDosing suspended: the restart delay countdown is in progress.Normal operating condition; if not required, reduce the delay in the parameters.
POWER SUPPLY
OUT OF RANGE
Supply voltage outside the permitted limits.Check the mains voltage.
FEED ON · FEED OFF · OKNormal operating status: pump dosing, pump stopped, or value at set point.No action required.
WARNING under a channelThe tube of that pump has reached its wear limit (yellow display).Replace the tube and reset the counter.
Calibration reminder90 days have passed since the last probe calibration (yellow display, the pump continues to operate).Recalibrate the probe.

Green display: normal operation; yellow: warning; red: alarm; white: stand-by. In the event of an alarm or warning, the details can be viewed by turning the knob to STATUS.

Tube life

The MAINTENANCE menu records the revolutions and operating hours of motors and tubes: when a tube reaches its wear limit, a warning appears below the channel and the display turns yellow. The limits refer to 1 bar of back pressure, 23 °C and chemicals that are not particularly aggressive.

Tube replacement

Switch off and disconnect the pump, close the valves and drain the liquid. Open the cover, remove the rotor cover disc and take out the slide with the worn tube; insert the new slide and bring the tube into position by turning the roller holder. Check by hand that it rotates freely, reassemble and carry out a dry test. If the roller holder is removed, the letter “A” must face the operator.

Motor error code

If a motor stops, the status screen shows the corresponding error code (from 1 to 13): by passing it on to our technical support service it is possible to identify immediately whether the problem concerns the power supply, wiring, temperature or communication.

Safety alarms

Always enable the maximum dosing time alarm (0 – 100 minutes) and the blocked probe alarm (100 – 254 minutes), and set dosing to stop in the absence of flow: without these protections there is a risk of dangerous overdosing.

If the problem persists, contact us. Before sending the pump for servicing, empty the pump head of chemical and dry it.

Summary

Main features

Electronic flow rate adjustment

According to the operating mode and the set parameters, the pump automatically adapts the injection frequency to ensure the required dosing.

Stand-by

Pump start and stop can be controlled remotely by means of a run/stop contact from a PLC or another source.

Alarm output

In the event of a fault, a volt-free contact is activated, configurable as normally open (N.O.) or normally closed (N.C.), to drive a visual or audible signalling device, send an SMS or report the event to a PLC.

Independent adjustment

The flow rate can be adjusted independently for each pump (or between the pump and the salt chlorinator), so that the correct quantities of pH adjuster and disinfectant are dosed according to the probe measurements.

Separate set points

One SET POINT dedicated to pH and one dedicated to the disinfectant (free chlorine, bromine, hydrogen peroxide or Redox).

pH control priority

Priority can be given to pH control, with disinfectant control starting only afterwards, which makes it more effective.

Level control (two tanks)

The pump is supplied with low-level probes for the tanks: when a chemical runs out, it shows the alarm on the display and activates the corresponding output.

Priming button

A dedicated button allows the lines to be filled with the chemical to be dosed.

Versatile mounting

Vertical installation, or horizontal installation by means of a dedicated bracket.

Flow control

In the absence of flow in the probe holder (circulation pump stopped), dosing is suspended and the alarm is triggered.

Remote control

Remote control and remote supervision

The WN pumps support two-way remote control: from the cloud portal, via Wi-Fi, Ethernet or 4G, settings can be changed, operation can be checked and alarms can be received, such as product depletion.

Wi-Fi

Allows connection to the NIMBUS cloud portal to change settings, check operation and receive alarms, such as the chemical running out.

Standard

Bluetooth

Pump programming directly from a smartphone.

Standard
NIMBUS web portal for remote control of the WN pumpsWeb portalPC, tablet and smartphone

Ethernet

Allows connection to the NIMBUS cloud portal via network cable to change settings, check operation and receive alarms.

Optional

Cellular network

Allows connection to the NIMBUS cloud portal via the 4G network to change settings, check operation and receive alarms.

Optional

The NIMBUS portal

A single account brings together all registered installations, each with its own devices: the web portal, free of charge and with no subscription, can be accessed from a PC, Mac, tablet or smartphone and allows every parameter to be both viewed and changed, with an encrypted connection and protected access.

The NIMBUS portal on monitor, laptop, tablet and smartphone

Overview

On a single screen: probe readings, chemical levels, pump activation thresholds and active alarms, with the status of installations and devices (normal, warning, alarm, standby, not connected).

Installation map

Installations appear on an interactive map with their status and open with a click; for each one, the local weather conditions and temperature are also shown.

History and charts

Archive of measurements and alarms, available for consultation at any time with charts and numerical reports exportable in Excel format.

Alarms and notifications

Alarm thresholds for readings, dosing, faulty probe and out-of-range readings, with notification by e-mail or SMS depending on the communication system; a warning is also issued when an installation remains disconnected beyond the set time.

Set points and dosing

Remote modification of the set points, of the dosing pump activation thresholds and of the corresponding hourly flow rate.

Inputs and outputs

Status of relays, pulse outputs, digital inputs and current outputs, with the name assigned to each connection.

Maintenance calendar

Tasks are scheduled by installation or by device and assigned to technicians; a reminder is sent by e-mail two days before the due date. Each task is shown as scheduled, due, overdue or completed.

Team and permissions

The main account has full access and creates the technicians’ accounts, each enabled only for the assigned installations and devices; the last login and activity of each technician are visible.

Reports and activity log

Reports on devices, tasks and technicians, downloadable in PDF or CSV with the customer’s logo; the log keeps the history of operations and disconnections.

Customisation

Logo, main colour and light or dark theme; the tiles on the main screen can be rearranged by dragging them. Two installations can be displayed side by side for comparison.

Guided registration

Each device is added through a guided procedure: the model is recognised automatically and associated with the installation, together with the technician to be contacted.

NIMBUS portal: Real-time readings, counters and timers
Real-time readings, counters and timers
NIMBUS portal: Free chlorine and temperature trends
Free chlorine and temperature trends
NIMBUS portal: Set point and operating mode of each channel
Set point and operating mode of each channel
NIMBUS portal: Status of relays, pulses, inputs and mA outputs
Status of relays, pulses, inputs and mA outputs

Technical advice

Tell us about your application: our technical staff will recommend the most suitable model, configuration and accessories.

Contact

Tell us about your plant

Call or write to us: a technician will reply with a tailored proposal of controllers, pumps, probes and accessories.

What do you need?
Please enter your name.
Please enter a valid email address.
Please enter your message.

Describe your plant: type, water volume or flow rate, parameters to be controlled.

You must accept the privacy notice to continue.