Solenoid dosing pump

AMS MF

Multifunction diaphragm dosing pump with display, for flow rates up to 60 l/h and back pressures up to 25 bar: it doses at a constant rate or in proportion to a pulse-output water meter or to 0-4/20 mA and 0-10 V signals, also in ppm, as a percentage and in batches. The volume of each injection is adjusted mechanically; level control, the stand-by input and the flow sensor input are standard.

  • Multifunction with display
  • Water meter and mA input
  • Up to 25 bar
  • Up to 220 l/h with compressed air
AMS MF dosing pump
220l/hMaximum flow rate
25barMaximum pressure
26Configurations
50,000cPMaximum viscosity
The model

AMS MF

AMS MF dosing pump
Multifunction

AMS MF

Constant dosing or dosing proportional to 0-4/20 mA current loop or 0-10 V signals or to a pulse-output water meter.

  • Digital constant
  • Multiply
  • Divide
  • PPM
  • Millilitres per quintal (100 kg)
  • Percentage
  • Batch
  • mA
  • Volt
  • External constant
  • Pause / work
Available versions
AMS P MF AMS P MFPMMA pump head for viscous liquids up to 50,000 cP.

Pump head: PVDF, PP, PMMA or AISI 316L

Operation

Dosing modes

Digital constant

The pump doses at a constant frequency, determined by the SPH (strokes/hour), SPM (strokes/minute) or LPH (litres/hour) values set during programming.

External constant

When the run contact closes, the pump doses the set quantity of chemical.

Pause / work

The pump runs the programmed cycle: during the WORK time it doses the set quantity of chemical; during the PAUSE time dosing is suspended.

PPM

Dosing is calculated from the pulses of the pulse-output water meter and the set PPM value; the concentration of the chemical and the volume per stroke can be programmed.

Millilitres per quintal (100 kg)

Dosing is calculated from the pulses of the pulse-output water meter and the set MLQ value (millilitres per quintal, i.e. per 100 kg).

Batch

A pulse from an external contact starts the dosing of the set quantity; pause and work cycles can be programmed.

mA

The 0-4/20 mA current loop signal controls dosing proportionally, between the set minimum and maximum values.

Volt

The 0-10 V voltage signal controls dosing proportionally, between the set minimum and maximum values.

Technical data

Performance and configurations

The pump code is made up of the model name and the performance: maximum pressure in bar as two digits followed by the flow rate in l/h (AMS MF 2505 = 25 bar, 5 l/h). It is followed by the pump head code and the power supply code, listed in the tables at the end of this section. Performance varies with the working back pressure and with the characteristics of the chemical.

Manual air bleed

Suitable for most chemicals: the standard configuration for the most common applications.

CodeMax pressure (bar)Max flow rate (l/h)Delivery tube (mm)Suction tube (mm)cc per stroke
AMS MF 25052554 x 64 x 60.7
AMS MF 151015104 x 64 x 61.4
AMS MF 101510156 x 86 x 82.08
AMS MF 07207206 x 86 x 82.8
AMS MF 03403408 x 108 x 125.6
AMS MF 02602608 x 108 x 127.7

Tube sizes may vary with the pump head material. The cc per stroke refer to the mechanical stroke adjustment set at 100%.

Automatic air bleed

Required with chemicals that release gas (e.g. peroxides), to prevent the pump from becoming air-locked.

CodeMax pressure (bar)Max flow rate (l/h)Delivery tube (mm)Suction tube (mm)
AMSA MF 253.2253.24 x 64 x 6
AMSA MF 15061564 x 64 x 6
AMSA MF 101010106 x 86 x 8
AMSA MF 07137136 x 86 x 8
AMSA MF 03303308 x 108 x 12
AMSA MF 02382388 x 108 x 12

Medium-viscosity liquids

For chemicals with a viscosity between 100 and 8,000 cP.

CodeMax pressure (bar)Max flow rate (l/h)
AMS MF LPV 2505255
AMS MF LPV 15101510
AMS MF LPV 10151015
AMS MF LPV 0720720
AMS MF LPV 0340340
AMS MF LPV 0260260

Nominal flow rate measured with water at room temperature. The pump head is made of PMMA with manual air bleed; the package includes a 3/4” injection valve, a 16 x 22 PVC suction tube and an 8 x 12 PE delivery tube.

High-viscosity liquids

For chemicals with a viscosity between 8,000 and 50,000 cP.

CodeMax pressure (bar)Max flow rate (l/h)cc per stroke
AMS P MF 0802820.28
AMS P MF 0604640.56
AMS P MF 04104101.4
AMS P MF 04254253.5
AMS P MF 01401405.6

Nominal flow rate measured with water at room temperature: with viscous liquids the flow rate is lower. 20 x 27 suction tube and 16 x 22 delivery tube, 1” suction valve and 3/4” delivery valve; this version is supplied without injection valve, level probe and foot filter.

Compressed air

For dosing large quantities of chemical in industrial applications.

CodeMax pressure (bar)Max flow rate (l/h)Delivery tube (mm)Suction tube (mm)cc per strokeAir consumption (l/min)
AMS AC MF 105010508 x 108 x 126.9430
AMS AC MF 05140514013 x 1612 x 1819.4430
AMS AC MF 00220022013 x 1612 x 1830.5630

The pump requires both an electrical supply and compressed air at 6 to 10 bar, free of lubricant and condensate; the air tube connection is 6 x 8. The pump head is made of PVDF with manual air bleed.

Technical specifications

SpecificationValue
Strokes per minuteFrom 1 stroke per hour to 120 strokes per minute
Linearity of the mechanical adjustmentFrom 30 to 100%
Average power draw at maximum flow rate42 W at 230 VAC; 24 W at 115 VAC
Peak current2.5 A
Maximum chemical viscosity100 cP; 8,000 cP with the pump head for viscous liquids
Maximum suction height1.5 m
Ambient temperature10 – 45 °C
Chemical temperature0 – 50 °C
Transport and storage temperature10 – 50 °C
Relative humidity85% up to 40 °C, 70% at 45 °C, non-condensing
Maximum altitude2,000 m
Protection ratingIP65
Noise level57.4 dB(A)
Weight9 kg
HousingPP
MountingHorizontal, floor or wall

Values for the standard version and the automatic air bleed version.

Viscous liquid and compressed air versions

SpecificationAMS P MFAMS AC MF
Maximum chemical viscosity50,000 cP100 cP
Strokes per minuteFrom 1 stroke per hour to 120 strokes per minute1 – 120
Average power draw at maximum flow rate42 W at 230 VAC7 W
Compressed air supply—6 – 10 bar
Ambient temperature10 – 45 °C0 – 45 °C
Transport and storage temperature10 – 50 °C−10 – 50 °C
Noise level78.3 dB(A)78.3 dB(A)
Weight9 kg4.5 kg
Electrical power suppliesCodes 00, 0S, 01 and 03All codes in the table

Pump head codes

CodePump headSealsValvesBallsMax viscosity (cP)
KPVDFFKM BPVDFCeramic100
PPVDFEPDMPVDFCeramic100
YPVDFNBRPVDFCeramic100
VPPFKM BPPCeramic100
DPPEPDMPPCeramic100
JPVDFFKM B + PTFEPVDFCeramic100
APMMAFKM BPVDFCeramic100
ZAISI 316LFKM BAISI 316LAISI 316L100
$PMMAFKM BPPStainless steel, Hastelloy spring8,000
B (AMS P)PMMAFKM BPPPTFE, Hastelloy spring50,000

PTFE diaphragm in all versions. The delivery tube is PVDF, or PE with PP pump heads and with code $; the suction tube is PVC. The stainless steel pump head (Z) is supplied without tubes.

Pump head codes of the AMS AC version

CodePump headSealsValvesBalls
KPVDFFKM BPVDFCeramic
PPVDFEPDMPVDFCeramic
WPVDFNBRPVDFCeramic
TPVDFFKM B + PTFEPVDFCeramic
APMMAFKM BPPCeramic
ZAISI 316LFKM BAISI 316LAISI 316L

PTFE diaphragm; maximum chemical viscosity 100 cP.

Power supply codes

CodePower supply
00230 VAC, Schuko plug
0S230 VAC, Australian plug
01230 VAC, no plug
03115 VAC, US plug
0424 VAC, no plug
0512 VDC (some models only)
0724 VDC

Voltage range and fuses

Power supplyVoltage rangeFuse
230 VAC190 – 265 VAC1.25 A
115 VAC90 – 135 VAC1.6 A
24 VAC20 – 32 VAC6.3 A
12 VDC10 – 16 VDC5 A

Supplied with

  • PVDF foot filter with level probe
  • 0.3 bar PVDF injection valve
  • Delivery, suction and drain tubes (2 m each)
  • Input signal cable (2.5 m)
  • Alarm and stand-by cable (2 m)
  • 5 × 20 time-delay fuse
  • Mounting kit
  • Operating manual

Pump head materials

Pump head in PVDF

PVDF

Suitable for most acids, for peroxides and for sodium hypochlorite (chlorine).

Pump head in PP

PP

Suitable for sodium hydroxide (caustic soda).

Pump head in AISI 316L

AISI 316L

Suitable for peracetic acid and sodium hydroxide.

Pump head in PMMA

PMMA

Suitable for medium and high viscosity substances.

Learn more: chemical compatibility of materials →

Special versions

Special versions

In addition to the standard configuration, versions dedicated to particular applications are available; the performance of each is given in the technical data. The pages by application compare the suitable pumps of all the series.

AMSA Series

AMSA Series

Self-venting pump head, required with chemicals that release gas (e.g. sodium hypochlorite and peroxides): it vents the gas and prevents the pump from locking.

Technical support

Troubleshooting and error messages

The most frequent causes of malfunction and the corrective actions to check before contacting technical support.

Learn more: the pump does not prime and does not dose →

If the pump…

The pump strokes normally, but the chemical is not dosed
  • Air in the hydraulic circuitCheck fittings and tubing, tighten any loose ones and bleed the air.
  • Suction tube emptiedThe pump has lost its prime: repeat the priming procedure.
  • Foot filter cloggedRemove the lance or filter from the tank and clean it.
  • Gas released by the chemicalOpen the bleed valve to discharge the gas; if this recurs, fit a self-bleeding pump head.
No strokes, or weak and damped stroke
  • Valve balls blocked by crystallisation of the chemicalClean the valves and run the pump with 2 – 3 litres of water instead of the chemical; if the problem persists, replace the valves.
  • Injection valve cloggedReplace the injection valve.
The pump does not switch on
  • No power supplyCheck the mains connection and that the voltage matches the rated value.
  • Protection fuse blownReplace the fuse with one of the same rating.
  • Faulty circuit boardThe board must be replaced: contact our technical support service.

Display of the MF models

MessageMeaningAction
ALARM LEVELChemical in the tank has run out.Restore the chemical level in the tank.
ALARM SEFLThe flow sensor has detected an excessive number of empty strokes, or the automatic re-priming has failed.Check the SEFL sensor, prime the pump manually, then switch it off and on again.
OVER FLOWThe required operating frequency exceeds the rated value.Check the set parameters and the pump flow rate, then switch it off and on again.
ALARM STROKEThe set flow rate exceeds the rated value.Check the set parameters and the flow rate, then switch the pump off and on again.
ALARM POWERSupply voltage outside the permitted limits.Check that the voltage matches the rating plate data, then switch the pump off and on again.
ALARM BATCHBatch dosing interrupted by a change of state of the external contact.Check that the connected contact matches the pump configuration, then switch off and on again.
INPUT OPENNo input signal in mA or Volt mode.Check the external signal and its connection.
ERROR DATAInconsistent set values.Check the values again; if they are correct and the error persists, the pump is undersized for the required dosing.
ERROR MEMError in the settings memory.Restore the factory values with the LOAD DEFAULT procedure.
WRONG ENTRYInvalid setting, for example the same value for the signal minimum and maximum.Set distinct, correct values.
Incorrect passwordThe password entered does not match the stored one.If it has been lost, restore the value 0000 with the RESET PASSWORD procedure.

The # symbol on the display indicates one or more active alarms, which can be viewed on the ALARM QTY screen.

Flow rate between 30 and 100%

Adjustment is linear between 30 and 100%: below 30% the actual flow rate may differ from the expected one and must therefore be checked.

Priming

Connect all the tubing, open the bleed valve and set the adjustment to 100%; start the pump and close the bleed valve as soon as the chemical comes out. With viscous liquids the operation can be assisted with a 20 cc syringe applied to the bleed port.

Factory settings

With the pump switched off, hold down both arrow keys and restore power: LOAD DEFAULT appears and the programming is reset to the factory values (password 0000).

If the problem persists, contact us. Before sending the pump for servicing, empty the pump head of chemical and dry it.

Summary

Main features

Electronic flow rate adjustment

According to the operating mode and the set parameters, the pump automatically adapts the injection frequency to ensure the required dosing.

Mechanical flow rate adjustment

The knob reduces the stroke length of the diaphragm, i.e. the volume of each injection and, consequently, the maximum flow rate. This offers two advantages:
Linear dosing: a high number of small-volume injections promotes mixing of the chemical into the water flow and avoids concentration peaks.
Accuracy at low dosing rates: with a 10 l/h pump required to dose 1 l/h, reducing the stroke length to 50% brings the maximum flow rate down to 5 l/h and doubles the injection frequency. Particularly suitable in combination with the pulse-output water meter.

Digital display

The integrated LCD display allows the pump to be programmed and its operating status to be monitored at all times.

Level control

The pump is supplied with a low-level probe for the tank: when the chemical runs out, it shows the alarm on the display and activates the corresponding output.

Stand-by

Pump start and stop can be controlled remotely by means of a run/stop contact from a PLC or another source.

Flow sensor

A flow sensor can be connected to check every single injection: if one or more injections are missed, the pump performs an automatic re-priming and recovers the lost injections; if this fails, it activates the alarm output.

Alarm output

In the event of a fault, a volt-free contact is activated, configurable as normally open (N.O.) or normally closed (N.C.), to drive a visual or audible signalling device, send an SMS or report the event to a PLC.

Priming button

A dedicated button allows the lines to be filled with the chemical to be dosed.

Versatile mounting

Horizontal installation, or vertical installation by means of a dedicated bracket.

Technical advice

Tell us about your application: our technical staff will recommend the most suitable model, configuration and accessories.

Contact

Tell us about your plant

Call or write to us: a technician will reply with a tailored proposal of controllers, pumps, probes and accessories.

What do you need?
Please enter your name.
Please enter a valid email address.
Please enter your message.

Describe your plant: type, water volume or flow rate, parameters to be controlled.

You must accept the privacy notice to continue.