Skip to content
Swimming pool systems

WDpHCl Peroxide

The WDpHCl Peroxide controller measures pH and hydrogen peroxide and controls two integrated solenoid dosing pumps, one for the pH corrector and one for the hydrogen peroxide; probe holder, measuring cell and sample filter are pre-assembled on a panel. Hydrogen peroxide (active oxygen) is measured by the SCL 9/200 closed amperometric cell, on a 0 to 200 mg/l scale, with pH and temperature compensation performed in the probe; typical set points are 30 mg/l and pH 7. Since peroxide releases gas, the version with automatic degassing is recommended.

  • pH and hydrogen peroxide
  • SCL 9/200 closed amperometric cell
  • pH control priority
  • Up to 7 bar and 10 l/h
WDpHCl Peroxide system on a panel
Panel-mounted
WDpHCl Peroxide controller
WDpHCl Peroxide
2Solenoid pumps
10l/hMaximum flow rate
7barMaximum pressure
0.1mg/lPeroxide resolution
How it works

The treatment circuit of a swimming pool

The pool water circulates continuously between the pool and the plant room, where it is filtered, analysed and disinfected before being returned.

Learn more: swimming pool water →
Illustration: the water enters the skimmer and the filtration pump sends it to the sand filter
1

Filtration

The water is drawn in through the skimmer and sent by the filtration pump to the filter, which retains the suspended impurities.

Typical layout

Typical layout

The treatment system is installed in the plant room, downstream of the filter: the probes analyse a water sample and injection takes place on the delivery pipe to the pool.

Typical layout of a swimming pool installation: pool with skimmer and return inlet, filtration pump, filter, WDpHCl Peroxide panel with the pH pump, the peroxide pump and the injection lines, sample filter and probe holder, make-up with water meter and motorised valve
Components

Basic components

The system is supplied pre-assembled on a plastic panel, ready for connection to the pool delivery pipe.

WDpHCl Peroxide controller

Controller with two dosing pumps

Controller and two solenoid diaphragm dosing pumps in a single unit, one for the pH corrector and one for the hydrogen peroxide; colour status display.

WDpHCl Peroxide pump →
pH electrodes

pH electrode

EpHS combination electrode with BNC connection, range 0 – 14 pH, temperature-compensable.

pH electrodes →
SCL9 closed amperometric cell for hydrogen peroxide

SCL9 closed amperometric cell

Cell with a selective membrane: hydrogen peroxide in mg/l, 0 – 200 mg/l scale, 0.1 mg/l resolution, with pH and temperature compensation performed in the probe.

SCL cells →
PEF flow-through probe holder

Flow-through probe holder

In PMMA, with sample flow rate adjustment and a proximity flow sensor that stops dosing when there is no circulation; upstream, the 5" sample filter at 50 µm.

Probe holders →
Operation

Operation in the swimming pool

1

pH priority

The controller first adjusts the pH and only then doses the hydrogen peroxide.

2

Proportional dosing

The pumps progressively reduce their flow rate as the values approach the set points.

3

Alarms

Product levels, no flow in the probe holder, maximum dosing time and faulty probe.

Flow rates

Pump flow rates

Pressure and flow rate

  • 6 l/h at 7 bar
  • 1 l/h at 5 bar
  • 10 l/h at 3 bar
  • 7 l/h at 3 bar with automatic degassing (WAD 0307)
Colour display

Colour-coded status indication

The display colour changes according to the operating status, so that an alarm can be recognised even from a distance.

Display Green

Green

Normal operation according to the set parameters, no active alarms.

Display Yellow

Yellow

Non-blocking alarm, for example waiting for an external signal.

Display Red

Red

Blocking alarm, for example the chemical in the tank running out.

Display White

White

Pump stopped by an external control signal (stand-by).

Settings from the display

pH and free hydrogen peroxide
pH and free hydrogen peroxide
Hydrogen peroxide set point
Hydrogen peroxide set point
Technical data

Probe data sheet

pH electrode

EpHS
Pressure7 bar (3.5 bar)
ConnectionBNC
BodyEpoxy
Minimum conductivity100 µS
Temperature70 °C (80 °C)
Cable0.8 m
Diameter12 mm

All models: combination electrode, range 0 – 14 pH, resolution 0.01.

Closed amperometric cell

SCL9
MeasurementHydrogen peroxide
Measuring range0 – 200 mg/l
Resolution0.1
Operating pH1 – 11
Operating pressure1 bar

All models: 2 electrodes, selective membrane, automatic temperature compensation, operating temperature 1 – 40 °C, water flow 30 l/h.

Applications

Where it is used

For private swimming pools.

WDpHCl Peroxide system on a panel

Private swimming pools

Residential pools, where free chlorine, Redox, hydrogen peroxide and salt are all options.

Private swimming pools →
Installation

Installation

1

Pre-assembled

All systems are supplied pre-assembled on a plastic panel, in a watertight box or on a skid, with solenoid or peristaltic dosing pumps.

2

In the plant room

Injection takes place on the delivery line, downstream of the filter, by means of an injection valve or lance; the probes analyse a water sample in the flow-through probe holder.

Probe holders →
3

Interlock with the filtration pump

The controller must always remain powered, to maintain the polarisation of the electrodes; when the filtration pump stops it goes into stand-by, continuing to measure without dosing.

Remote control

System remote control

The controllers support two-way remote access (read and write) through the web portal from a PC, tablet or smartphone: measurements can be viewed, set points, dosing and alarms changed, alarms received and logs downloaded. Alternatively, they can be integrated into your PLC via Modbus.

Ethernet

Connection to the web portal via network cable: measurements, set points, dosing and alarms accessible from a PC, tablet or smartphone.

Wi-Fi

Wireless connection to the web portal, with the same functions as the cable connection.

4G

Connection via the 4G network for installations without a local network, with alarm notification by SMS or e-mail.

NIMBUS web portal for remote control of the systemsWeb portalPC, tablet and smartphone

Modbus RTU

Integration into your PLC via serial port.

Modbus TCP/IP

Integration into your PLC or SCADA via Ethernet network.

0-4/20 mA current loop output

Current signal proportional to the measured value, for remote monitoring or for controlling pumps and other instrumentation.

The NIMBUS portal

A single account brings together all registered installations, each with its own devices: the web portal, free of charge and with no subscription, can be accessed from a PC, Mac, tablet or smartphone and allows every parameter to be both viewed and changed, with an encrypted connection and protected access.

The NIMBUS portal on monitor, laptop, tablet and smartphone

Overview

On a single screen: probe readings, chemical levels, pump activation thresholds and active alarms, with the status of installations and devices (normal, warning, alarm, standby, not connected).

Installation map

Installations appear on an interactive map with their status and open with a click; for each one, the local weather conditions and temperature are also shown.

History and charts

Archive of measurements and alarms, available for consultation at any time with charts and numerical reports exportable in Excel format.

Alarms and notifications

Alarm thresholds for readings, dosing, faulty probe and out-of-range readings, with notification by e-mail or SMS depending on the communication system; a warning is also issued when an installation remains disconnected beyond the set time.

Set points and dosing

Remote modification of the set points, of the dosing pump activation thresholds and of the corresponding hourly flow rate.

Inputs and outputs

Status of relays, pulse outputs, digital inputs and current outputs, with the name assigned to each connection.

Maintenance calendar

Tasks are scheduled by installation or by device and assigned to technicians; a reminder is sent by e-mail two days before the due date. Each task is shown as scheduled, due, overdue or completed.

Team and permissions

The main account has full access and creates the technicians’ accounts, each enabled only for the assigned installations and devices; the last login and activity of each technician are visible.

Reports and activity log

Reports on devices, tasks and technicians, downloadable in PDF or CSV with the customer’s logo; the log keeps the history of operations and disconnections.

Customisation

Logo, main colour and light or dark theme; the tiles on the main screen can be rearranged by dragging them. Two installations can be displayed side by side for comparison.

Guided registration

Each device is added through a guided procedure: the model is recognised automatically and associated with the installation, together with the technician to be contacted.

PLC integration

As an alternative to the portal, the Modbus RTU or TCP/IP port allows integration into the plant supervision system.

NIMBUS portal: Real-time readings, counters and timers
Real-time readings, counters and timers
NIMBUS portal: Free chlorine and temperature trends
Free chlorine and temperature trends
NIMBUS portal: Set point and operating mode of each channel
Set point and operating mode of each channel
NIMBUS portal: Status of relays, pulses, inputs and mA outputs
Status of relays, pulses, inputs and mA outputs

Technical advice

Tell us the pool volume, the type of use and the characteristics of the plant room: we will propose the most suitable version and accessories.

Contact

Tell us about your plant

Call or write to us: a technician will reply with a tailored proposal of controllers, pumps, probes and accessories.

What do you need?
Please enter your name.
Please enter a valid email address.
Please enter your message.

Describe your plant: type, water volume or flow rate, parameters to be controlled.

You must accept the privacy notice to continue.