Filtration
The water is drawn in through the skimmer and sent by the filtration pump to the filter, which retains the suspended impurities.
The WDpHCl Peroxide controller measures pH and hydrogen peroxide and controls two integrated solenoid dosing pumps, one for the pH corrector and one for the hydrogen peroxide; probe holder, measuring cell and sample filter are pre-assembled on a panel. Hydrogen peroxide (active oxygen) is measured by the SCL 9/200 closed amperometric cell, on a 0 to 200 mg/l scale, with pH and temperature compensation performed in the probe; typical set points are 30 mg/l and pH 7. Since peroxide releases gas, the version with automatic degassing is recommended.
The pool water circulates continuously between the pool and the plant room, where it is filtered, analysed and disinfected before being returned.
Learn more: swimming pool water →
The water is drawn in through the skimmer and sent by the filtration pump to the filter, which retains the suspended impurities.
A water sample flows through the probe holder of the panel, where pH and hydrogen peroxide are measured continuously.
The controller regulates pH as a priority: the pump doses the pH adjuster until the set value is reached.
With the pH at the correct values, hydrogen peroxide is dosed, at a flow rate that is progressively reduced as the set point is approached.
The filtered and disinfected water is returned to the pool through the return inlets.
Water lost through evaporation or discharge is replaced; with the Centurio POOL the volume fed in is measured by a pulse-output water meter.
The treatment system is installed in the plant room, downstream of the filter: the probes analyse a water sample and injection takes place on the delivery pipe to the pool.

The system is supplied pre-assembled on a plastic panel, ready for connection to the pool delivery pipe.
Controller and two solenoid diaphragm dosing pumps in a single unit, one for the pH corrector and one for the hydrogen peroxide; colour status display.
WDpHCl Peroxide pump →
EpHS combination electrode with BNC connection, range 0 – 14 pH, temperature-compensable.
pH electrodes →
Cell with a selective membrane: hydrogen peroxide in mg/l, 0 – 200 mg/l scale, 0.1 mg/l resolution, with pH and temperature compensation performed in the probe.
SCL cells →
In PMMA, with sample flow rate adjustment and a proximity flow sensor that stops dosing when there is no circulation; upstream, the 5" sample filter at 50 µm.
Probe holders →The controller first adjusts the pH and only then doses the hydrogen peroxide.
The pumps progressively reduce their flow rate as the values approach the set points.
Product levels, no flow in the probe holder, maximum dosing time and faulty probe.
The display colour changes according to the operating status, so that an alarm can be recognised even from a distance.
Normal operation according to the set parameters, no active alarms.
Non-blocking alarm, for example waiting for an external signal.
Blocking alarm, for example the chemical in the tank running out.
Pump stopped by an external control signal (stand-by).
| EpHS | |
|---|---|
| Pressure | 7 bar (3.5 bar) |
| Connection | BNC |
| Body | Epoxy |
| Minimum conductivity | 100 µS |
| Temperature | 70 °C (80 °C) |
| Cable | 0.8 m |
| Diameter | 12 mm |
All models: combination electrode, range 0 – 14 pH, resolution 0.01.
| SCL9 | |
|---|---|
| Measurement | Hydrogen peroxide |
| Measuring range | 0 – 200 mg/l |
| Resolution | 0.1 |
| Operating pH | 1 – 11 |
| Operating pressure | 1 bar |
All models: 2 electrodes, selective membrane, automatic temperature compensation, operating temperature 1 – 40 °C, water flow 30 l/h.
For private swimming pools.
Residential pools, where free chlorine, Redox, hydrogen peroxide and salt are all options.
Private swimming pools →All systems are supplied pre-assembled on a plastic panel, in a watertight box or on a skid, with solenoid or peristaltic dosing pumps.
Injection takes place on the delivery line, downstream of the filter, by means of an injection valve or lance; the probes analyse a water sample in the flow-through probe holder.
Probe holders →The controller must always remain powered, to maintain the polarisation of the electrodes; when the filtration pump stops it goes into stand-by, continuing to measure without dosing.
The controllers support two-way remote access (read and write) through the web portal from a PC, tablet or smartphone: measurements can be viewed, set points, dosing and alarms changed, alarms received and logs downloaded. Alternatively, they can be integrated into your PLC via Modbus.
Connection to the web portal via network cable: measurements, set points, dosing and alarms accessible from a PC, tablet or smartphone.
Wireless connection to the web portal, with the same functions as the cable connection.
Connection via the 4G network for installations without a local network, with alarm notification by SMS or e-mail.
Web portalPC, tablet and smartphone
Integration into your PLC via serial port.
Integration into your PLC or SCADA via Ethernet network.
Current signal proportional to the measured value, for remote monitoring or for controlling pumps and other instrumentation.
A single account brings together all registered installations, each with its own devices: the web portal, free of charge and with no subscription, can be accessed from a PC, Mac, tablet or smartphone and allows every parameter to be both viewed and changed, with an encrypted connection and protected access.
On a single screen: probe readings, chemical levels, pump activation thresholds and active alarms, with the status of installations and devices (normal, warning, alarm, standby, not connected).
Installations appear on an interactive map with their status and open with a click; for each one, the local weather conditions and temperature are also shown.
Archive of measurements and alarms, available for consultation at any time with charts and numerical reports exportable in Excel format.
Alarm thresholds for readings, dosing, faulty probe and out-of-range readings, with notification by e-mail or SMS depending on the communication system; a warning is also issued when an installation remains disconnected beyond the set time.
Remote modification of the set points, of the dosing pump activation thresholds and of the corresponding hourly flow rate.
Status of relays, pulse outputs, digital inputs and current outputs, with the name assigned to each connection.
Tasks are scheduled by installation or by device and assigned to technicians; a reminder is sent by e-mail two days before the due date. Each task is shown as scheduled, due, overdue or completed.
The main account has full access and creates the technicians’ accounts, each enabled only for the assigned installations and devices; the last login and activity of each technician are visible.
Reports on devices, tasks and technicians, downloadable in PDF or CSV with the customer’s logo; the log keeps the history of operations and disconnections.
Logo, main colour and light or dark theme; the tiles on the main screen can be rearranged by dragging them. Two installations can be displayed side by side for comparison.
Each device is added through a guided procedure: the model is recognised automatically and associated with the installation, together with the technician to be contacted.
As an alternative to the portal, the Modbus RTU or TCP/IP port allows integration into the plant supervision system.
Tell us the pool volume, the type of use and the characteristics of the plant room: we will propose the most suitable version and accessories.
Call or write to us: a technician will reply with a tailored proposal of controllers, pumps, probes and accessories.