Colour display
Multicolour backlit display that indicates the different operating states by changing colour. Programming via a single knob.
The LDsCL controller for free chlorine continuously measures the hypochlorous acid in the water and drives the hypochlorite dosing pump until the set point is reached. With the SCL3N and SCL3S closed amperometric cells the measurement is automatically compensated for pH and temperature; the SCL18 self-cleaning cell is intended for domestic hot water, while the ECL open amperometric cells are used in swimming pools.
It acquires the measurement from the cell and controls the dosing pump in proportion to the measured value.
Multicolour backlit display that indicates the different operating states by changing colour. Programming via a single knob.
Proportional, ON/OFF, PWM and PID dosing, with delayed dosing start.
Permanent data storage and a system log viewable on the display; the internal log can be exported to a USB memory stick for processing with a spreadsheet.
Chemical level, no flow, maximum dosing time exceeded, probe failure, out-of-range reading; audible or visual signalling via the alarm output.
By changing colour, the controller’s backlit display indicates the different operating states, which can be recognised even from a distance.
Measurement and dosing according to the set parameters.
Controller in stand-by.
Warning signal, for example the chemical level.
Alarm signal, for example from the probe.
The instrument is available in two versions, which differ in the number of inputs and outputs: the PLUS version adds the meter input, PID control, a second level input, a second dosing pump output, the 0-4/20 mA current loop outputs and the outputs for probe self-cleaning and for the circulation pump.
| BASIC | PLUS | |
|---|---|---|
| Measuring channels | 1 + temperature | 1 + temperature |
| Level inputs | 1 | 2 |
| Flow input | 1 | 1 |
| Stand-by input | 1 | 1 |
| Meter input | – | 1 |
| Outputs for pumps and loads (relays) | 1 (ON/OFF, PWM) | 2 (ON/OFF, PWM, PID) |
| Proportional outputs for dosing pumps | 1 | 2 |
| Alarm output | 1 | 1 |
| 0-4/20 mA current loop outputs | 2 on request | 3 |
| Probe self-cleaning output | – | 1 |
| Circulation pump output | – | 1 |
| Modbus RTU | ● | Optional |
| Ethernet, Wi-Fi, 4G, USB | Optional | Optional |
Inputs, outputs, control modes and alarms of the controller.
For measuring the concentration of hypochlorous acid in drinking water, water supply networks, hot and cold domestic water circuits and process water. The closed amperometric cell automatically compensates for pH and temperature; the ECL open amperometric cell allows free chlorine to be measured in swimming pools, without compensation.
SCL closed or ECL open amperometric cells are connected to the LDsCL controller, resulting in the different versions.
Learn more: Redox, open amperometric cell and closed amperometric cell →
The electrodes are protected by a selective membrane that allows only the oxidant of interest to be measured, without interference from other substances. Automatic temperature compensation (and pH compensation for free chlorine), resolution down to 0.001 mg/l.
SCL cells →
Membrane-free, with 3 electrodes (one measuring and two reference), with ball self-cleaning: suitable up to 70 °C and less sensitive to fouling. For free chlorine (SCL18) and chlorine dioxide (SCL17).
SCL17 and SCL18 →
Direct measurement of free chlorine in mg/l in swimming pool water, including salt water.
ECL cells →The cell consists of an electronic section and a galvanic section.
Learn more: Redox, open amperometric cell and closed amperometric cell →The measuring electrodes are protected from direct contact with the water by a semi-permeable membrane: only the specific oxidant is measured, without interference from other substances that could alter the measurement.
The electrodes of the galvanic section detect the electric current generated by the dissociation of the oxidant.
The cell electronics compensate the reading for temperature (and, where applicable, pH) and send the signal to the controller, which shows the concentration in mg/l on the display.
Measuring range, resolution and characteristics of the cells for measuring free chlorine. The controller is common to all parameters: inputs, outputs and connections are described in the controller sections.
| Parameter | Range | Resolution | Cell | Compensation |
|---|---|---|---|---|
| Free chlorine | 0 – 0.5 mg/l 0 – 2 mg/l 0 – 20 mg/l | 0.001 mg/l 0.001 mg/l 0.01 mg/l | SCL3N, SCL3S, SCL18 · ECL | pH and temperature (SCL) None (ECL) |
| Temperature | 0 – 100 °C | 0.1 °C | – | – |
| Characteristic | Value |
|---|---|
| Average power consumption | 25 W |
| Relay outputs | 5 A at 230 VAC, fuse-protected |
| Delayed dosing start | Up to 60 minutes |
| Networking | Up to 31 controllers |
| Ambient temperature | −10 – 50 °C |
| Relative humidity | 0 – 95 %, non-condensing |
| Protection rating | IP65 |
| Housing | ABS |
| Weight | 1.45 kg |
| Mounting | Wall-mounted, with four fixing points |
The controller is the core of the measuring and dosing system: for each application, the system page gives the composition, the installation diagram and the installation.
Measurement of residual free chlorine with an amperometric cell and dosing of hypochlorite in proportion to the measured value.
The system →
Volumetric dosing, control of residual chlorine or Redox, chlorine dioxide, monochloramine and water supply networks.
The sector →
Prevention guide: biofilm, regulatory framework, comparison of disinfectants and systems for domestic hot water.
The sector →
Free chlorine or Redox and pH, with integrated or dedicated pumps.
The sector →For wastewater and for plants with special requirements the system is defined on the characteristics of the plant: contact us.
For measuring the concentration of hypochlorous acid in drinking water, water supply networks, hot and cold domestic water circuits and process water. The closed amperometric cell automatically compensates for pH and temperature; the ECL open amperometric cell allows free chlorine to be measured in swimming pools, without compensation.
Closed membrane cell, for cold water.
Cell details →
Self-cleaning 3-electrode cell, for hot water up to 70 °C.
Cell details →
Open amperometric cell, for swimming pools.
Cell details →| SCL3N/0.5 | SCL3N/2 | SCL3N/20 | SCL18/0.5 | SCL18/2 | SCL18/20 | SCL3S/20 | |
|---|---|---|---|---|---|---|---|
| Measuring range | 0 – 0.5 mg/l | 0 – 2 mg/l | 0 – 20 mg/l | 0 – 0.5 mg/l | 0 – 2 mg/l | 0 – 20 mg/l | 0 – 20 mg/l |
| Resolution | 0.001 | 0.001 | 0.01 | 0.001 | 0.001 | 0.01 | 0.01 |
| Free chlorine | Inorganic | Inorganic | Inorganic | Inorganic | Inorganic | Inorganic | Organic and inorganic |
| Water | Fresh | Fresh | Fresh | Fresh | Fresh | Fresh | Fresh or salt |
| Electrodes | 2 | 2 | 2 | 3 | 3 | 3 | 2 |
| Selective membrane | ● | ● | ● | – | – | – | ● |
| Automatic compensation | pH and temperature | pH and temperature | pH and temperature | pH and temperature | pH and temperature | pH and temperature | Temperature |
| Self-cleaning | – | – | – | ● | ● | ● | – |
| Operating pH | 5 – 9.5 | 5 – 9.5 | 5 – 9.5 | 5 – 9 | 5 – 9 | 5 – 9 | 5.5 – 9.5 |
| Operating temperature | 1 – 40 °C | 1 – 40 °C | 1 – 40 °C | 5 – 70 °C | 5 – 70 °C | 5 – 70 °C | 5 – 45 °C |
| Operating pressure | 1 bar | 1 bar | 1 bar | 8 bar | 8 bar | 8 bar | 1 bar |
| Water flow | 30 l/h | 30 l/h | 30 l/h | 40 l/h | 40 l/h | 40 l/h | 30 l/h |
| Sample water conductivity | 500 – 10.000 µS/cm | 500 – 10.000 µS/cm | 500 – 10.000 µS/cm | 0.05 µS/cm – 10 mS/cm | 0.05 µS/cm – 10 mS/cm | 0.05 µS/cm – 10 mS/cm | 30 – 10.000 µS/cm |
| Response time (T90) | approx. 2 min | approx. 2 min | approx. 2 min | approx. 60 s | approx. 60 s | approx. 60 s | approx. 2 min |
| Start-up time | 1 – 24 h (usually 6 h) | 1 – 24 h (usually 6 h) | 1 – 24 h (usually 6 h) | 1 – 24 h | 1 – 24 h | 1 – 24 h | Approx. 6 h at first start-up, approx. 3 h afterwards |
| Replacement electrolyte | ELESCL3N | ELESCL3N | ELESCL3N | ELESCL18 | ELESCL18 | ELESCL18 | ELESCL3 |
| Replacement membrane | MESCL3 | MESCL3 | MESCL3 | – | – | – | MESCL3 |
| Materials | PP/PMMA shaft, PPE membrane cap | PP/PMMA shaft, PPE membrane cap | PP/PMMA shaft, PPE membrane cap | PEEK shaft, PPE clamping disc, gold electrodes, EPDM O-ring | PEEK shaft, PPE clamping disc, gold electrodes, EPDM O-ring | PEEK shaft, PPE clamping disc, gold electrodes, EPDM O-ring | PVC shaft, PPE membrane cap |
| Dimensions | Ø 25 × 241 mm | Ø 25 × 241 mm | Ø 25 × 241 mm | Ø 25 × 241 mm | Ø 25 × 241 mm | Ø 25 × 241 mm | Ø 25 × 241 mm |
| Maintenance | Electrolyte replacement every 3 – 6 months | Electrolyte replacement every 3 – 6 months | Electrolyte replacement every 3 – 6 months | Electrolyte replacement every 3 – 6 months; electrode cleaning every 4 – 12 weeks | Electrolyte replacement every 3 – 6 months; electrode cleaning every 4 – 12 weeks | Electrolyte replacement every 3 – 6 months; electrode cleaning every 4 – 12 weeks | Electrolyte replacement every 3 – 6 months; membrane cap life of about one year, depending on water quality |
Closed amperometric cells operate in water containing chlorine: an absence of chlorine for more than 100 consecutive hours damages the cell. A filter should be installed upstream of the probe holder.
| ECL6 | ECL6/E | ECL7 | ECL12 | ECL12/E | ECL20 | ECL21 | |
|---|---|---|---|---|---|---|---|
| Water | Fresh | Fresh | Fresh | Sea | Sea | Fresh | Sea |
| Flow stabiliser | ● | ● | ● | ● | ● | – | – |
| Flow sensor and regulation | ● | ● | ● | ● | ● | – | – |
| Probe holder for | Temperature, pH, Redox | Temperature | Temperature, pH, Redox (PG13.5) | Temperature, pH, Redox | Temperature | – | – |
All models: amperometric system, range 0 – 10 mg/l, resolution 0.01, organic and inorganic free chlorine, operating temperature 1 – 40 °C, pressure 0.4 – 5 bar, water flow 40 l/h.
The controllers support two-way remote access (read and write) through the web portal from a PC, tablet or smartphone: measurements can be viewed, set points, dosing and alarms changed, alarms received and logs downloaded. Alternatively, they can be integrated into your PLC via Modbus.
Connection to the web portal via network cable: measurements, set points, dosing and alarms accessible from a PC, tablet or smartphone.
Wireless connection to the web portal, with the same functions as the cable connection.
Connection via the 4G network for installations without a local network, with alarm notification by SMS or e-mail.
Web portalPC, tablet and smartphone
Integration into your PLC via serial port.
Current signal proportional to the measured value, for remote monitoring or for controlling pumps and other instrumentation.
Download of the logged data to a USB memory stick, for archiving and analysis with a spreadsheet.
One communication type at a time: Ethernet, Wi-Fi, 4G or Modbus RTU (built into the BASIC versions, optional on the PLUS versions). 0-4/20 mA current loop outputs standard on the PLUS versions, optional on the BASIC versions; meter input on the PLUS versions only.
A single account brings together all registered installations, each with its own devices: the web portal, free of charge and with no subscription, can be accessed from a PC, Mac, tablet or smartphone and allows every parameter to be both viewed and changed, with an encrypted connection and protected access.
On a single screen: probe readings, chemical levels, pump activation thresholds and active alarms, with the status of installations and devices (normal, warning, alarm, standby, not connected).
Installations appear on an interactive map with their status and open with a click; for each one, the local weather conditions and temperature are also shown.
Archive of measurements and alarms, available for consultation at any time with charts and numerical reports exportable in Excel format.
Alarm thresholds for readings, dosing, faulty probe and out-of-range readings, with notification by e-mail or SMS depending on the communication system; a warning is also issued when an installation remains disconnected beyond the set time.
Remote modification of the set points, of the dosing pump activation thresholds and of the corresponding hourly flow rate.
Status of relays, pulse outputs, digital inputs and current outputs, with the name assigned to each connection.
Tasks are scheduled by installation or by device and assigned to technicians; a reminder is sent by e-mail two days before the due date. Each task is shown as scheduled, due, overdue or completed.
The main account has full access and creates the technicians’ accounts, each enabled only for the assigned installations and devices; the last login and activity of each technician are visible.
Reports on devices, tasks and technicians, downloadable in PDF or CSV with the customer’s logo; the log keeps the history of operations and disconnections.
Logo, main colour and light or dark theme; the tiles on the main screen can be rearranged by dragging them. Two installations can be displayed side by side for comparison.
Each device is added through a guided procedure: the model is recognised automatically and associated with the installation, together with the technician to be contacted.
As an alternative to the portal, the Modbus RTU port allows integration into the plant supervision system.
Tell us the product to be dosed, the volumes of water treated and the characteristics of the plant: we will propose the most suitable cell, pump and accessories.
Call or write to us: a technician will reply with a tailored proposal of controllers, pumps, probes and accessories.