Skip to content
pH · amperometric cell

LDpHCL

The LDpHCL controller measures and controls pH and an oxidant read by an amperometric cell, normally free chlorine, in addition to temperature. pH is corrected by proportional dosing and has priority over the second channel, which drives the disinfectant pump below the set point. With the SCL closed amperometric cell, the chlorine measurement is compensated for pH and temperature directly in the probe.

  • pH and free chlorine
  • SCL or ECL cells
  • 0.001 mg/l resolution
  • pH priority
LDpHCL system pre-assembled on a panel with two dosing pumps, filter and probe holder
LDpHCLon a panel
LDpHCL controller
Controller
0 – 14pHpH range
0 – 20mg/lMaximum free chlorine range
0.001mg/lChlorine resolution
3Proportional outputs
Controller

The controller

It acquires the measurements from the two probes and controls the dosing pumps in proportion to the measured values.

Colour display

Multicolour backlit display that indicates the different operating states by changing colour. Programming via a single knob.

Four modes

Proportional, ON/OFF, PWM and PID dosing, with delayed dosing start.

Data storage

Permanent data storage and a system log viewable on the display; the internal log can be exported to a USB memory stick for processing with a spreadsheet.

Alarms

Chemical level, no flow, maximum dosing time exceeded, probe failure, out-of-range reading; audible or visual signalling via the alarm output.

Colour display

Colour-coded status indication

The backlit display shows both measurements, the temperature and the status of the outputs at the same time and, by changing colour, indicates the different operating states, which can be recognised even from a distance.

Display Normal operation

Normal operation

Measurement and dosing according to the set parameters.

Display Stand-by

Stand-by

Controller in stand-by.

Display Warning

Warning

Warning signal, for example the chemical level.

Display Alarm

Alarm

Alarm signal, for example from the probe.

Versions

BASIC and PLUS versions

The instrument is available in two versions, which differ in the number of inputs and outputs: the PLUS version adds the meter input, PID control, and the circulation pump output.

BASICPLUS
Measuring channels2 + temperature2 + temperature
Level inputs33
Flow input11
Stand-by input11
Meter input–1
Outputs for pumps and loads (relays)2 (ON/OFF, PWM)2 (ON/OFF, PWM, PID)
Proportional outputs for dosing pumps33
Alarm output11
0-4/20 mA current loop outputsOptionalOptional
Circulation pump output–1
Modbus RTU●Optional
Ethernet, Wi-Fi, 4G, USBOptionalOptional
Data sheet

Controller data sheet

Inputs, outputs, control modes and alarms of the controller.

Inputs

  • pH electrode (BNC connector)
  • Amperometric cell (terminal block)
  • PT100 temperature probe
  • Flow sensor
  • Stand-by
  • pH+ corrector level
  • pH− corrector level
  • Disinfectant level
  • Pulse-output water meter or mA signal (PLUS)

Outputs

  • 2 proportional pulse outputs for pH
  • 1 proportional pulse output for chlorine
  • Relay output for pH (ON/OFF or PWM)
  • Relay output for chlorine (ON/OFF or PWM)
  • Powered output for the flocculant
  • Alarm output
  • Optional 0-4/20 mA outputs: pH, chlorine and temperature
  • Circulation pump (PLUS)

Control

  • Proportional
  • ON/OFF
  • PWM
  • PID (PLUS)
  • Delayed start

Alarms

  • Chemical levels
  • No flow
  • Maximum dosing time
  • Probe failure
  • Out-of-range reading

Power supply

  • 230 VAC
  • 12 – 24 VDC
Measurements

pH and free chlorine

The first channel measures pH with a BNC-connector electrode; the second reads an amperometric cell connected to the terminal block. The PT100 probe provides the water temperature.

pH

The range is 0 to 14 pH with a resolution of 0.01 pH. The reading is temperature-compensated by the controller.

pH electrodes →

Amperometric cell

The SCL closed amperometric cell measures free chlorine, total chlorine, chlorine dioxide, bromine, hydrogen peroxide, peracetic acid, ozone or chlorites; the ECL open amperometric cell measures free chlorine in swimming pool water.

SCL amperometric cells →

Temperature

The PT100 probe reads the temperature from 0 to 100 °C, which is used to compensate the measurements.

Temperature probes →

Probe data sheets

pH electrodes
ElectrodePressureConnectionBodyMinimum conductivityJunctionTemperatureCableDiameterNotes
EpHS7 bar (3.5 bar)BNCEpoxy100 µS–70 °C (80 °C)0.8 m12 mm–
EpHM7 bar (3.5 bar)BNCEpoxy100 µS–70 °C (80 °C)4.5 m12 mm–
EpHL7 bar (3.5 bar)BNCEpoxy100 µS–70 °C (80 °C)15 m12 mm–
EpHSN67 bar (3.5 bar)SN6 with PG13.5 threadEpoxy100 µS–70 °C (80 °C)1 – 100 m12 mm–
EpHMD/1007 barBNCEpoxy100 µSDouble100 °C4.5 m12 mm–
EpHM/D7 bar (3.5 bar)BNCEpoxy100 µSDouble70 °C (80 °C)4.5 m12 mm–
EpHM/D/SN67 bar (3.5 bar)SN6 with PG13.5 threadEpoxy100 µSDouble70 °C (80 °C)1 – 100 m12 mm–
EpHMD/LI7 bar (3.5 bar)SN6 with PG13.5 threadEpoxy3 µSDouble70 °C (80 °C)1 – 100 m12 mmFor low-conductivity water
EpHSC7 bar (3.5 bar)BNCEpoxy100 µSDouble70 °C (80 °C)4.5 m12 mmSelf-cleaning
EpHSC/SN67 bar (3.5 bar)SN6 with PG13.5 threadEpoxy100 µSDouble70 °C (80 °C)1 – 100 m12 mmSelf-cleaning
EpHM/HF7 bar (3.5 bar)BNCEpoxy100 µSDouble70 °C (80 °C)4.5 m12 mmResistant to 1% hydrofluoric acid
EpHSN6 GK10 barSN6Glass150 µS–−5 / 135 °C1 – 100 m12 mmHigh temperature

All models: combination electrode, range 0 – 14 pH, resolution 0.01.

Closed amperometric cells – Free chlorine
SCL3N/0.5SCL3N/2SCL3N/20SCL18/0.5SCL18/2SCL18/20SCL3S/20
Measuring range0 – 0.5 mg/l0 – 2 mg/l0 – 20 mg/l0 – 0.5 mg/l0 – 2 mg/l0 – 20 mg/l0 – 20 mg/l
Resolution0.0010.0010.010.0010.0010.010.01
Free chlorineInorganicInorganicInorganicInorganicInorganicInorganicOrganic and inorganic
WaterFreshFreshFreshFreshFreshFreshFresh or salt
Electrodes2223332
Selective membrane●●●–––●
Automatic compensationpH and temperaturepH and temperaturepH and temperaturepH and temperaturepH and temperaturepH and temperatureTemperature
Self-cleaning–––●●●–
Operating pH5 – 9.55 – 9.55 – 9.55 – 95 – 95 – 95.5 – 9.5
Operating temperature1 – 40 °C1 – 40 °C1 – 40 °C5 – 70 °C5 – 70 °C5 – 70 °C5 – 45 °C
Operating pressure1 bar1 bar1 bar8 bar8 bar8 bar1 bar
Water flow30 l/h30 l/h30 l/h40 l/h40 l/h40 l/h30 l/h
Closed amperometric cells – Chlorine dioxide
SCL2/0.5SCL2/2SCL2/20SCL17/0.5SCL17/2SCL17/20
Measuring range0 – 0.5 mg/l0 – 2 mg/l0 – 20 mg/l0 – 0.5 mg/l0 – 2 mg/l0 – 20 mg/l
Resolution0.0010.0010.010.0010.0010.01
Electrodes222333
Selective membrane●●●–––
Self-cleaning–––●●●
Operating pH4 – 114 – 114 – 115 – 95 – 95 – 9
Operating temperature1 – 40 °C1 – 40 °C1 – 40 °C5 – 70 °C5 – 70 °C5 – 70 °C
Operating pressure1 bar1 bar1 bar8 bar8 bar8 bar
Water flow30 l/h30 l/h30 l/h40 l/h40 l/h40 l/h

Automatic temperature compensation on all models.

Closed amperometric cells – Other oxidants
SCL8/2SCL8/20SBR/20SCL9SCL11/200SCL11/2000SCL10SCT
MeasurementTotal chlorineTotal chlorineBromineHydrogen peroxidePeracetic acidPeracetic acidOzoneChlorites
Measuring range0 – 2 mg/l0 – 20 mg/l0 – 20 mg/l0 – 200 mg/l0 – 200 mg/l0 – 2,000 mg/l0 – 2 mg/l
0 – 20 mg/l
0 – 2 mg/l
Resolution0.0010.010.010.10.110.001
0.01
0.001
Operating pH4 – 124 – 126.5 – 9.51 – 111 – 91 – 92 – 115.5 – 9.5
Operating pressure1 bar1 bar0.5 bar1 bar1 bar1 bar1 bar1 bar

All models: 2 electrodes, selective membrane, automatic temperature compensation, operating temperature 1 – 40 °C, water flow 30 l/h.

ECL open amperometric cells
ECL6ECL6/EECL7ECL12ECL12/EECL20ECL21
WaterFreshFreshFreshSeaSeaFreshSea
Flow stabiliser●●●●●––
Flow sensor and regulation●●●●●––
Probe holder forTemperature, pH, RedoxTemperatureTemperature, pH, Redox (PG13.5)Temperature, pH, RedoxTemperature––

All models: amperometric system, range 0 – 10 mg/l, resolution 0.01, organic and inorganic free chlorine, operating temperature 1 – 40 °C, pressure 0.4 – 5 bar, water flow 40 l/h.

The model

LDpHCL

LDpHCL system on a panel
pH · amperometric cell

LDpHCL

Control of pH (proportional dosing above the set point) and of a parameter measured with an amperometric cell (below the set point): with the SCL closed amperometric cell, free chlorine, total chlorine, chlorine dioxide, bromine, hydrogen peroxide, peracetic acid, ozone or chlorites; with the ECL open amperometric cell, free chlorine in swimming pool water.

Technical data

Technical data

Controller specifications taken from the manufacturer’s technical documentation. Ranges and resolution depend on the installed probes, described in the data sheets at the end of this section.

Technical specifications

SpecificationValue
MeasurementspH and free chlorine or another oxidant with an amperometric cell, plus temperature
Measuring range0 – 14 pH; free chlorine 0 – 0.5 / 0 – 2 / 0 – 10 / 0 – 20 mg/l depending on the selected amperometric cell
Resolution0.001 mg/l (free chlorine), 0.01 pH
Probe inputsBNC connector for pH, terminal block for the amperometric cell
Flocculant outputPowered, 85 – 264 VAC; active except in stand-by and flow alarm
Measured temperature0 – 100 °C, PT100 probe
Power supply85 – 264 VAC, 50/60 Hz
Alternative power supply9 – 18 or 18 – 36 VDC, optional
Average power consumption25 W
Relay outputs2, maximum load 5 A at 230 VAC, for ON/OFF or PWM devices
Proportional pulse outputs3, optocoupled
Alarm outputPowered, 85 – 264 VAC
0-4/20 mA outputs3, optional (one for each measurement and one for temperature), maximum load 500 Ω
Communication portRS485
FusesMain 6 A T, outputs 3.15 A T
Reading accuracy1% on both channels
Ambient temperature−10 – 45 °C
Transport and storage temperature−10 – 50 °C
Installation classII, pollution degree 2
Protection ratingIP65
Housing materialABS
Dimensions (W × H × D)213 × 264 × 124 mm
Weight1.45 kg
MountingWall-mounted, with 4 fixing points

Measurement compensation

The free chlorine measurement depends on pH. In water, free chlorine is present in two forms: hypochlorous acid, the active form, and hypochlorite ion, the less effective form for disinfection. The pH determines their proportion: to indicate the actual mg/l, the controller corrects the chlorine reading according to the measured pH.

The pH measurement depends on temperature, because the electrode response changes with the water temperature: the controller corrects the pH according to the temperature read by the probe.

Compatible controllers therefore correct the pH for temperature and the chlorine for pH, giving the most accurate possible reading of both parameters. In SCL closed amperometric cells the pH and temperature compensation takes place directly in the probe, and the controller compensates the pH reading for temperature; with ECL open amperometric cells the controller handles the whole compensation chain.

ECL open amperometric cellSCL closed amperometric cell
Free chlorine – compensated forpHpH and temperature
pH – compensated forTemperatureTemperature
Complete systems

Complete systems with LDpHCL

The controller is the core of the measuring and dosing system: for each application, the system page gives the composition, the installation diagram and the installation.

pH and chlorine

LDpHCLpH and chlorine

The system continuously measures the pH and the concentration of an oxidant, normally free chlorine, with a pH electrode and an amperometric cell housed in the same flow-through probe holder, and drives the dosing pumps of the pH corrector and of the disinfectant in proportion to the deviation from their set points.

The system →
Public and semi-public swimming pools

Public and semi-public swimming pools

pH and free chlorine with amperometric cell (UNI 10637:2024, Italian standard): WDpHCl, WNpHCl, LDpHCl, Centurio POOL; dechlorination of discharges and footbath.

The system →
Private swimming pools

Private swimming pools

Chlorine, bromine, Redox, peroxide or salt electrochlorinator: WD integrated pumps or WN peristaltic pumps, or an LD controller with separate pumps.

The system →
Drinking water

Disinfection and residual in the networkDrinking water

Volumetric dosing, control of residual chlorine or Redox, chlorine dioxide, monochloramine and water supply networks.

The system →
Fire-fighting water tanks

Disinfection of standing waterFire-fighting water tanks

Free chlorine or Redox and pH, with integrated or dedicated pumps.

The system →

For wastewater and for plants with special requirements the system is defined on the characteristics of the plant: contact us.

Remote control

System remote control

The controllers support two-way remote access (read and write) through the web portal from a PC, tablet or smartphone: measurements can be viewed, set points, dosing and alarms changed, alarms received and logs downloaded. Alternatively, they can be integrated into your PLC via Modbus.

Ethernet

Connection to the web portal via network cable: measurements, set points, dosing and alarms accessible from a PC, tablet or smartphone.

Optional (one only)

Wi-Fi

Wireless connection to the web portal, with the same functions as the cable connection.

Optional (one only)

4G

Connection via the 4G network for installations without a local network, with alarm notification by SMS or e-mail.

Optional (one only)
NIMBUS web portal for remote control of the systemsWeb portalPC, tablet and smartphone

Modbus RTU

Integration into your PLC via serial port.

Standard (BASIC), optional (PLUS)

0-4/20 mA current loop output

Current signal proportional to the measured value, for remote monitoring or for controlling pumps and other instrumentation.

Optional (3 outputs)

USB port

Download of the logged data to a USB memory stick, for archiving and analysis with a spreadsheet.

Optional

One communication type at a time: Ethernet, Wi-Fi, 4G or Modbus RTU (built into the BASIC versions, optional on the PLUS versions). 0-4/20 mA current loop outputs optional; meter input on the PLUS versions only.

The NIMBUS portal

A single account brings together all registered installations, each with its own devices: the web portal, free of charge and with no subscription, can be accessed from a PC, Mac, tablet or smartphone and allows every parameter to be both viewed and changed, with an encrypted connection and protected access.

The NIMBUS portal on monitor, laptop, tablet and smartphone

Overview

On a single screen: probe readings, chemical levels, pump activation thresholds and active alarms, with the status of installations and devices (normal, warning, alarm, standby, not connected).

Installation map

Installations appear on an interactive map with their status and open with a click; for each one, the local weather conditions and temperature are also shown.

History and charts

Archive of measurements and alarms, available for consultation at any time with charts and numerical reports exportable in Excel format.

Alarms and notifications

Alarm thresholds for readings, dosing, faulty probe and out-of-range readings, with notification by e-mail or SMS depending on the communication system; a warning is also issued when an installation remains disconnected beyond the set time.

Set points and dosing

Remote modification of the set points, of the dosing pump activation thresholds and of the corresponding hourly flow rate.

Inputs and outputs

Status of relays, pulse outputs, digital inputs and current outputs, with the name assigned to each connection.

Maintenance calendar

Tasks are scheduled by installation or by device and assigned to technicians; a reminder is sent by e-mail two days before the due date. Each task is shown as scheduled, due, overdue or completed.

Team and permissions

The main account has full access and creates the technicians’ accounts, each enabled only for the assigned installations and devices; the last login and activity of each technician are visible.

Reports and activity log

Reports on devices, tasks and technicians, downloadable in PDF or CSV with the customer’s logo; the log keeps the history of operations and disconnections.

Customisation

Logo, main colour and light or dark theme; the tiles on the main screen can be rearranged by dragging them. Two installations can be displayed side by side for comparison.

Guided registration

Each device is added through a guided procedure: the model is recognised automatically and associated with the installation, together with the technician to be contacted.

PLC integration

As an alternative to the portal, the Modbus RTU port allows integration into the plant supervision system.

NIMBUS portal: Real-time readings, counters and timers
Real-time readings, counters and timers
NIMBUS portal: Free chlorine and temperature trends
Free chlorine and temperature trends
NIMBUS portal: Set point and operating mode of each channel
Set point and operating mode of each channel
NIMBUS portal: Status of relays, pulses, inputs and mA outputs
Status of relays, pulses, inputs and mA outputs

Technical advice

Tell us the parameters to be monitored and the characteristics of the plant: we will propose the most suitable controller, probes, pumps and accessories.

Contact

Tell us about your plant

Call or write to us: a technician will reply with a tailored proposal of controllers, pumps, probes and accessories.

What do you need?
Please enter your name.
Please enter a valid email address.
Please enter your message.

Describe your plant: type, water volume or flow rate, parameters to be controlled.

You must accept the privacy notice to continue.