Colour display
Multicolour backlit display that indicates the different operating states by changing colour. Programming via a single knob.
The LDpHCL controller measures and controls pH and an oxidant read by an amperometric cell, normally free chlorine, in addition to temperature. pH is corrected by proportional dosing and has priority over the second channel, which drives the disinfectant pump below the set point. With the SCL closed amperometric cell, the chlorine measurement is compensated for pH and temperature directly in the probe.
It acquires the measurements from the two probes and controls the dosing pumps in proportion to the measured values.
Multicolour backlit display that indicates the different operating states by changing colour. Programming via a single knob.
Proportional, ON/OFF, PWM and PID dosing, with delayed dosing start.
Permanent data storage and a system log viewable on the display; the internal log can be exported to a USB memory stick for processing with a spreadsheet.
Chemical level, no flow, maximum dosing time exceeded, probe failure, out-of-range reading; audible or visual signalling via the alarm output.
The backlit display shows both measurements, the temperature and the status of the outputs at the same time and, by changing colour, indicates the different operating states, which can be recognised even from a distance.
Measurement and dosing according to the set parameters.
Controller in stand-by.
Warning signal, for example the chemical level.
Alarm signal, for example from the probe.
The instrument is available in two versions, which differ in the number of inputs and outputs: the PLUS version adds the meter input, PID control, and the circulation pump output.
| BASIC | PLUS | |
|---|---|---|
| Measuring channels | 2 + temperature | 2 + temperature |
| Level inputs | 3 | 3 |
| Flow input | 1 | 1 |
| Stand-by input | 1 | 1 |
| Meter input | – | 1 |
| Outputs for pumps and loads (relays) | 2 (ON/OFF, PWM) | 2 (ON/OFF, PWM, PID) |
| Proportional outputs for dosing pumps | 3 | 3 |
| Alarm output | 1 | 1 |
| 0-4/20 mA current loop outputs | Optional | Optional |
| Circulation pump output | – | 1 |
| Modbus RTU | ● | Optional |
| Ethernet, Wi-Fi, 4G, USB | Optional | Optional |
Inputs, outputs, control modes and alarms of the controller.
The first channel measures pH with a BNC-connector electrode; the second reads an amperometric cell connected to the terminal block. The PT100 probe provides the water temperature.
The range is 0 to 14 pH with a resolution of 0.01 pH. The reading is temperature-compensated by the controller.
pH electrodes →The SCL closed amperometric cell measures free chlorine, total chlorine, chlorine dioxide, bromine, hydrogen peroxide, peracetic acid, ozone or chlorites; the ECL open amperometric cell measures free chlorine in swimming pool water.
SCL amperometric cells →The PT100 probe reads the temperature from 0 to 100 °C, which is used to compensate the measurements.
Temperature probes →| Electrode | Pressure | Connection | Body | Minimum conductivity | Junction | Temperature | Cable | Diameter | Notes |
|---|---|---|---|---|---|---|---|---|---|
| EpHS | 7 bar (3.5 bar) | BNC | Epoxy | 100 µS | – | 70 °C (80 °C) | 0.8 m | 12 mm | – |
| EpHM | 7 bar (3.5 bar) | BNC | Epoxy | 100 µS | – | 70 °C (80 °C) | 4.5 m | 12 mm | – |
| EpHL | 7 bar (3.5 bar) | BNC | Epoxy | 100 µS | – | 70 °C (80 °C) | 15 m | 12 mm | – |
| EpHSN6 | 7 bar (3.5 bar) | SN6 with PG13.5 thread | Epoxy | 100 µS | – | 70 °C (80 °C) | 1 – 100 m | 12 mm | – |
| EpHMD/100 | 7 bar | BNC | Epoxy | 100 µS | Double | 100 °C | 4.5 m | 12 mm | – |
| EpHM/D | 7 bar (3.5 bar) | BNC | Epoxy | 100 µS | Double | 70 °C (80 °C) | 4.5 m | 12 mm | – |
| EpHM/D/SN6 | 7 bar (3.5 bar) | SN6 with PG13.5 thread | Epoxy | 100 µS | Double | 70 °C (80 °C) | 1 – 100 m | 12 mm | – |
| EpHMD/LI | 7 bar (3.5 bar) | SN6 with PG13.5 thread | Epoxy | 3 µS | Double | 70 °C (80 °C) | 1 – 100 m | 12 mm | For low-conductivity water |
| EpHSC | 7 bar (3.5 bar) | BNC | Epoxy | 100 µS | Double | 70 °C (80 °C) | 4.5 m | 12 mm | Self-cleaning |
| EpHSC/SN6 | 7 bar (3.5 bar) | SN6 with PG13.5 thread | Epoxy | 100 µS | Double | 70 °C (80 °C) | 1 – 100 m | 12 mm | Self-cleaning |
| EpHM/HF | 7 bar (3.5 bar) | BNC | Epoxy | 100 µS | Double | 70 °C (80 °C) | 4.5 m | 12 mm | Resistant to 1% hydrofluoric acid |
| EpHSN6 GK | 10 bar | SN6 | Glass | 150 µS | – | −5 / 135 °C | 1 – 100 m | 12 mm | High temperature |
All models: combination electrode, range 0 – 14 pH, resolution 0.01.
| SCL3N/0.5 | SCL3N/2 | SCL3N/20 | SCL18/0.5 | SCL18/2 | SCL18/20 | SCL3S/20 | |
|---|---|---|---|---|---|---|---|
| Measuring range | 0 – 0.5 mg/l | 0 – 2 mg/l | 0 – 20 mg/l | 0 – 0.5 mg/l | 0 – 2 mg/l | 0 – 20 mg/l | 0 – 20 mg/l |
| Resolution | 0.001 | 0.001 | 0.01 | 0.001 | 0.001 | 0.01 | 0.01 |
| Free chlorine | Inorganic | Inorganic | Inorganic | Inorganic | Inorganic | Inorganic | Organic and inorganic |
| Water | Fresh | Fresh | Fresh | Fresh | Fresh | Fresh | Fresh or salt |
| Electrodes | 2 | 2 | 2 | 3 | 3 | 3 | 2 |
| Selective membrane | ● | ● | ● | – | – | – | ● |
| Automatic compensation | pH and temperature | pH and temperature | pH and temperature | pH and temperature | pH and temperature | pH and temperature | Temperature |
| Self-cleaning | – | – | – | ● | ● | ● | – |
| Operating pH | 5 – 9.5 | 5 – 9.5 | 5 – 9.5 | 5 – 9 | 5 – 9 | 5 – 9 | 5.5 – 9.5 |
| Operating temperature | 1 – 40 °C | 1 – 40 °C | 1 – 40 °C | 5 – 70 °C | 5 – 70 °C | 5 – 70 °C | 5 – 45 °C |
| Operating pressure | 1 bar | 1 bar | 1 bar | 8 bar | 8 bar | 8 bar | 1 bar |
| Water flow | 30 l/h | 30 l/h | 30 l/h | 40 l/h | 40 l/h | 40 l/h | 30 l/h |
| SCL2/0.5 | SCL2/2 | SCL2/20 | SCL17/0.5 | SCL17/2 | SCL17/20 | |
|---|---|---|---|---|---|---|
| Measuring range | 0 – 0.5 mg/l | 0 – 2 mg/l | 0 – 20 mg/l | 0 – 0.5 mg/l | 0 – 2 mg/l | 0 – 20 mg/l |
| Resolution | 0.001 | 0.001 | 0.01 | 0.001 | 0.001 | 0.01 |
| Electrodes | 2 | 2 | 2 | 3 | 3 | 3 |
| Selective membrane | ● | ● | ● | – | – | – |
| Self-cleaning | – | – | – | ● | ● | ● |
| Operating pH | 4 – 11 | 4 – 11 | 4 – 11 | 5 – 9 | 5 – 9 | 5 – 9 |
| Operating temperature | 1 – 40 °C | 1 – 40 °C | 1 – 40 °C | 5 – 70 °C | 5 – 70 °C | 5 – 70 °C |
| Operating pressure | 1 bar | 1 bar | 1 bar | 8 bar | 8 bar | 8 bar |
| Water flow | 30 l/h | 30 l/h | 30 l/h | 40 l/h | 40 l/h | 40 l/h |
Automatic temperature compensation on all models.
| SCL8/2 | SCL8/20 | SBR/20 | SCL9 | SCL11/200 | SCL11/2000 | SCL10 | SCT | |
|---|---|---|---|---|---|---|---|---|
| Measurement | Total chlorine | Total chlorine | Bromine | Hydrogen peroxide | Peracetic acid | Peracetic acid | Ozone | Chlorites |
| Measuring range | 0 – 2 mg/l | 0 – 20 mg/l | 0 – 20 mg/l | 0 – 200 mg/l | 0 – 200 mg/l | 0 – 2,000 mg/l | 0 – 2 mg/l 0 – 20 mg/l | 0 – 2 mg/l |
| Resolution | 0.001 | 0.01 | 0.01 | 0.1 | 0.1 | 1 | 0.001 0.01 | 0.001 |
| Operating pH | 4 – 12 | 4 – 12 | 6.5 – 9.5 | 1 – 11 | 1 – 9 | 1 – 9 | 2 – 11 | 5.5 – 9.5 |
| Operating pressure | 1 bar | 1 bar | 0.5 bar | 1 bar | 1 bar | 1 bar | 1 bar | 1 bar |
All models: 2 electrodes, selective membrane, automatic temperature compensation, operating temperature 1 – 40 °C, water flow 30 l/h.
| ECL6 | ECL6/E | ECL7 | ECL12 | ECL12/E | ECL20 | ECL21 | |
|---|---|---|---|---|---|---|---|
| Water | Fresh | Fresh | Fresh | Sea | Sea | Fresh | Sea |
| Flow stabiliser | ● | ● | ● | ● | ● | – | – |
| Flow sensor and regulation | ● | ● | ● | ● | ● | – | – |
| Probe holder for | Temperature, pH, Redox | Temperature | Temperature, pH, Redox (PG13.5) | Temperature, pH, Redox | Temperature | – | – |
All models: amperometric system, range 0 – 10 mg/l, resolution 0.01, organic and inorganic free chlorine, operating temperature 1 – 40 °C, pressure 0.4 – 5 bar, water flow 40 l/h.
Control of pH (proportional dosing above the set point) and of a parameter measured with an amperometric cell (below the set point): with the SCL closed amperometric cell, free chlorine, total chlorine, chlorine dioxide, bromine, hydrogen peroxide, peracetic acid, ozone or chlorites; with the ECL open amperometric cell, free chlorine in swimming pool water.
Controller specifications taken from the manufacturer’s technical documentation. Ranges and resolution depend on the installed probes, described in the data sheets at the end of this section.
| Specification | Value |
|---|---|
| Measurements | pH and free chlorine or another oxidant with an amperometric cell, plus temperature |
| Measuring range | 0 – 14 pH; free chlorine 0 – 0.5 / 0 – 2 / 0 – 10 / 0 – 20 mg/l depending on the selected amperometric cell |
| Resolution | 0.001 mg/l (free chlorine), 0.01 pH |
| Probe inputs | BNC connector for pH, terminal block for the amperometric cell |
| Flocculant output | Powered, 85 – 264 VAC; active except in stand-by and flow alarm |
| Measured temperature | 0 – 100 °C, PT100 probe |
| Power supply | 85 – 264 VAC, 50/60 Hz |
| Alternative power supply | 9 – 18 or 18 – 36 VDC, optional |
| Average power consumption | 25 W |
| Relay outputs | 2, maximum load 5 A at 230 VAC, for ON/OFF or PWM devices |
| Proportional pulse outputs | 3, optocoupled |
| Alarm output | Powered, 85 – 264 VAC |
| 0-4/20 mA outputs | 3, optional (one for each measurement and one for temperature), maximum load 500 Ω |
| Communication port | RS485 |
| Fuses | Main 6 A T, outputs 3.15 A T |
| Reading accuracy | 1% on both channels |
| Ambient temperature | −10 – 45 °C |
| Transport and storage temperature | −10 – 50 °C |
| Installation class | II, pollution degree 2 |
| Protection rating | IP65 |
| Housing material | ABS |
| Dimensions (W × H × D) | 213 × 264 × 124 mm |
| Weight | 1.45 kg |
| Mounting | Wall-mounted, with 4 fixing points |
The free chlorine measurement depends on pH. In water, free chlorine is present in two forms: hypochlorous acid, the active form, and hypochlorite ion, the less effective form for disinfection. The pH determines their proportion: to indicate the actual mg/l, the controller corrects the chlorine reading according to the measured pH.
The pH measurement depends on temperature, because the electrode response changes with the water temperature: the controller corrects the pH according to the temperature read by the probe.
Compatible controllers therefore correct the pH for temperature and the chlorine for pH, giving the most accurate possible reading of both parameters. In SCL closed amperometric cells the pH and temperature compensation takes place directly in the probe, and the controller compensates the pH reading for temperature; with ECL open amperometric cells the controller handles the whole compensation chain.
| ECL open amperometric cell | SCL closed amperometric cell | |
|---|---|---|
| Free chlorine – compensated for | pH | pH and temperature |
| pH – compensated for | Temperature | Temperature |
The controller is the core of the measuring and dosing system: for each application, the system page gives the composition, the installation diagram and the installation.
The system continuously measures the pH and the concentration of an oxidant, normally free chlorine, with a pH electrode and an amperometric cell housed in the same flow-through probe holder, and drives the dosing pumps of the pH corrector and of the disinfectant in proportion to the deviation from their set points.
The system →
pH and free chlorine with amperometric cell (UNI 10637:2024, Italian standard): WDpHCl, WNpHCl, LDpHCl, Centurio POOL; dechlorination of discharges and footbath.
The system →
Chlorine, bromine, Redox, peroxide or salt electrochlorinator: WD integrated pumps or WN peristaltic pumps, or an LD controller with separate pumps.
The system →
Volumetric dosing, control of residual chlorine or Redox, chlorine dioxide, monochloramine and water supply networks.
The system →
Free chlorine or Redox and pH, with integrated or dedicated pumps.
The system →For wastewater and for plants with special requirements the system is defined on the characteristics of the plant: contact us.
The controllers support two-way remote access (read and write) through the web portal from a PC, tablet or smartphone: measurements can be viewed, set points, dosing and alarms changed, alarms received and logs downloaded. Alternatively, they can be integrated into your PLC via Modbus.
Connection to the web portal via network cable: measurements, set points, dosing and alarms accessible from a PC, tablet or smartphone.
Wireless connection to the web portal, with the same functions as the cable connection.
Connection via the 4G network for installations without a local network, with alarm notification by SMS or e-mail.
Web portalPC, tablet and smartphone
Integration into your PLC via serial port.
Current signal proportional to the measured value, for remote monitoring or for controlling pumps and other instrumentation.
Download of the logged data to a USB memory stick, for archiving and analysis with a spreadsheet.
One communication type at a time: Ethernet, Wi-Fi, 4G or Modbus RTU (built into the BASIC versions, optional on the PLUS versions). 0-4/20 mA current loop outputs optional; meter input on the PLUS versions only.
A single account brings together all registered installations, each with its own devices: the web portal, free of charge and with no subscription, can be accessed from a PC, Mac, tablet or smartphone and allows every parameter to be both viewed and changed, with an encrypted connection and protected access.
On a single screen: probe readings, chemical levels, pump activation thresholds and active alarms, with the status of installations and devices (normal, warning, alarm, standby, not connected).
Installations appear on an interactive map with their status and open with a click; for each one, the local weather conditions and temperature are also shown.
Archive of measurements and alarms, available for consultation at any time with charts and numerical reports exportable in Excel format.
Alarm thresholds for readings, dosing, faulty probe and out-of-range readings, with notification by e-mail or SMS depending on the communication system; a warning is also issued when an installation remains disconnected beyond the set time.
Remote modification of the set points, of the dosing pump activation thresholds and of the corresponding hourly flow rate.
Status of relays, pulse outputs, digital inputs and current outputs, with the name assigned to each connection.
Tasks are scheduled by installation or by device and assigned to technicians; a reminder is sent by e-mail two days before the due date. Each task is shown as scheduled, due, overdue or completed.
The main account has full access and creates the technicians’ accounts, each enabled only for the assigned installations and devices; the last login and activity of each technician are visible.
Reports on devices, tasks and technicians, downloadable in PDF or CSV with the customer’s logo; the log keeps the history of operations and disconnections.
Logo, main colour and light or dark theme; the tiles on the main screen can be rearranged by dragging them. Two installations can be displayed side by side for comparison.
Each device is added through a guided procedure: the model is recognised automatically and associated with the installation, together with the technician to be contacted.