Skip to content
Fertigation systems

Fertigation with Centurio PRO

The Centurio PRO measures pH and conductivity at two points of the plant: the first controls the dosing of acid and fertiliser, the second is a safety point that checks the values of the water sent to the crops and signals an alarm when they leave the set thresholds.

  • pH and conductivity at two points
  • Control and safety
  • Acid and fertiliser
  • Up to 10 channels
Fertigation with Centurio PRO
Centurio PRO
Typical layout

Typical layout

Typical layout: fertigation with Centurio PRO, pH and conductivity at two points
Components

Basic components

Centurio PRO

Centurio PRO

Multi-channel controller with touch screen: up to 10 measuring channels and control of all the dosing pumps of the plant.

Centurio PRO →
pH electrodes

Two pH electrodes

One at the control point and one at the safety point; combination electrodes, 0 – 14 pH scale, with temperature compensation.

pH electrodes →
Conductivity probes

Two conductivity probes

One per point; conductive or inductive, depending on the measuring range and the water quality.

Conductivity probes →
Dosing pump

Dosing pumps

One for the acid and one for the fertiliser, controlled by the Centurio PRO.

Dosing pumps →
Injection lance

Injection lance

It introduces the product into the centre of the pipe, improving mixing; it can be withdrawn with the pipe under pressure.

Lances →
1

Control point

pH and conductivity measured after the injection control the acid pump and the fertiliser pump.

2

Safety point

A second pH electrode and a second conductivity probe check the water sent to the crops, independently of the control point.

3

Alarms

When the values at the safety point leave the set thresholds, the Centurio PRO signals an alarm.

4

Remote control

Readings, alarms and records of both points available from the web portal.

Technical data

Probe data sheets

pH electrodes
ElectrodePressureConnectionBodyMinimum conductivityJunctionTemperatureCableDiameterNotes
EpHS7 bar (3.5 bar)BNCEpoxy100 µS–70 °C (80 °C)0.8 m12 mm–
EpHM7 bar (3.5 bar)BNCEpoxy100 µS–70 °C (80 °C)4.5 m12 mm–
EpHL7 bar (3.5 bar)BNCEpoxy100 µS–70 °C (80 °C)15 m12 mm–
EpHSN67 bar (3.5 bar)SN6 with PG13.5 threadEpoxy100 µS–70 °C (80 °C)1 – 100 m12 mm–
EpHMD/1007 barBNCEpoxy100 µSDouble100 °C4.5 m12 mm–
EpHM/D7 bar (3.5 bar)BNCEpoxy100 µSDouble70 °C (80 °C)4.5 m12 mm–
EpHM/D/SN67 bar (3.5 bar)SN6 with PG13.5 threadEpoxy100 µSDouble70 °C (80 °C)1 – 100 m12 mm–
EpHMD/LI7 bar (3.5 bar)SN6 with PG13.5 threadEpoxy3 µSDouble70 °C (80 °C)1 – 100 m12 mmFor low-conductivity water
EpHSC7 bar (3.5 bar)BNCEpoxy100 µSDouble70 °C (80 °C)4.5 m12 mmSelf-cleaning
EpHSC/SN67 bar (3.5 bar)SN6 with PG13.5 threadEpoxy100 µSDouble70 °C (80 °C)1 – 100 m12 mmSelf-cleaning
EpHM/HF7 bar (3.5 bar)BNCEpoxy100 µSDouble70 °C (80 °C)4.5 m12 mmResistant to 1% hydrofluoric acid
EpHSN6 GK10 barSN6Glass150 µS–−5 / 135 °C1 – 100 m12 mmHigh temperature

All models: combination electrode, range 0 – 14 pH, resolution 0.01.

Conductive probes – ECDC

PVDF body, graphite electrodes.

ModelMountingConnectionRangeK factorTemperature compensation
ECDC/1In-line / bypassR3/4"0 – 20 mS1–
ECDCC/1In-line / bypassR3/4"0 – 20 mS1NTC 10K
ECDCCPT/1In-line / bypassR3/4"0 – 20 mS1PT100
ECDC/10In-line / bypassR3/4"0 – 200 mS10–
ECDCC/10In-line / bypassR3/4"0 – 200 mS10NTC 10K
ECDCCPT/10In-line / bypassR3/4"0 – 200 mS10PT100
ECDCIM/1ImmersionG1/2"0 – 20 mS1–
ECDCCIM/1ImmersionG1/2"0 – 20 mS1NTC 10K
ECDCCIMPT/1ImmersionG1/2"0 – 20 mS1PT100
ECDCIM/10ImmersionG1/2"0 – 200 mS10–
ECDCCIM/10ImmersionG1/2"0 – 200 mS10NTC 10K
ECDCCIMPT/10ImmersionG1/2"0 – 200 mS10PT100

Operating temperature 1 – 60 °C (100 °C at 2 bar), operating pressure 7 bar (2 bar at 100 °C).

Conductive probes – ECDI

PVDF body, stainless steel electrodes.

ModelMountingConnectionRangeK factorTemperature compensation
ECDI/1In-line / bypassR3/4"0 – 5 mS1–
ECDIC/1In-line / bypassR3/4"0 – 5 mS1NTC 10K
ECDICPT/1In-line / bypassR3/4"0 – 5 mS1PT100
ECDI/01In-line / bypassR3/4"0 – 200 µS0.1–
ECDIC/01In-line / bypassR3/4"0 – 200 µS0.1NTC 10K
ECDICPT/01In-line / bypassR3/4"0 – 200 µS0.1PT100
ECDIIM/1ImmersionG1/2"0 – 5 mS1–
ECDICIM/1ImmersionG1/2"0 – 5 mS1NTC 10K
ECDICPTIM/1ImmersionG1/2"0 – 5 mS1PT100
ECDIIM/01ImmersionG1/2"0 – 200 µS0.1–
ECDIIM/02ImmersionG1/2"0 – 500 µS0.2–
ECDICIM/01ImmersionG1/2"0 – 200 µS0.1NTC 10K
ECDICPTIM/01ImmersionG1/2"0 – 200 µS0.1PT100

Operating temperature 1 – 60 °C (100 °C at 2 bar), operating pressure 7 bar (2 bar at 100 °C).

Conductive probes – ECDHL

Epoxy body, platinum electrodes, diameter 12 mm.

ModelMountingRangeK factorTemperature compensation
ECDHL/1In-line / bypass0.2 – 20 mS1–
ECDHLC/1In-line / bypass0.2 – 20 mS1NTC 10K
ECDHLCPT/1In-line / bypass0.2 – 20 mS1PT100
ECDHL/01In-line / bypass0 – 200 µS0.1–
ECDHLC/01In-line / bypass0 – 200 µS0.1NTC 10K
ECDHLCPT/01In-line / bypass0 – 200 µS0.1PT100
ECDHL/10In-line / bypass20 – 200 mS10–
ECDHLC/10In-line / bypass20 – 200 mS10NTC 10K
ECDHLCPT/10In-line / bypass20 – 200 mS10PT100

Operating temperature 1 – 70 °C, operating pressure 7 bar.

Conductive probes – EICDC

Stainless steel body and electrodes, R3/4" connection, in-line or bypass mounting.

ModelRangeK factorTemperature compensationOperating temperature
EICDC/10 – 20 mS1NTC 10K1 – 130 °C
EICDCPT/10 – 20 mS1PT1001 – 130 °C
EICDC/010 – 200 µS0.1NTC 10K1 – 130 °C
EICDCPT/010 – 200 µS0.1PT1001 – 130 °C
EICDC/0010 – 20 µS0.01NTC 10K1 – 130 °C
EICDCPT/0010 – 20 µS0.01PT1001 – 130 °C
EICDCHPT/10 – 20 mS1PT1001 – 200 °C
EICDCHPT/010 – 200 µS0.1PT1001 – 200 °C
EICDCHPT/0010 – 20 µS0.01PT1001 – 200 °C

Operating pressure 15 bar.

Inductive probes
ECDINDPTECDSINDPT
Measuring range0.3 – 3 mS
0.3 – 30 mS
0.3 – 300 mS
0.3 – 10 mS
Measuring systemInductiveInductive
BodyPEEKPEEK
MountingIn-line / bypass / immersionIn-line / bypass / immersion
Temperature compensationPT100PT100
Operating temperature1 – 85 °C (100 °C for short periods)1 – 85 °C (100 °C for short periods)
Operating pressure8 bar8 bar
Other systems

Fertigation

The requirements of the sector and the comparison with the other systems available.

Fertigation systems →
Installations

Installation examples

Systems are supplied pre-assembled and tested, in the form best suited to the plant room: on a panel, in a cabinet or on a skid (with cover, in a box or on a frame), or custom-built. Some examples are shown below.

System on a panel with controller, dosing pumps, filter and probe holder

On a panel

Controller, pumps, probe holder and accessories mounted and wired on a wall panel.

System in a cabinet with panel and chemical tanks

In a cabinet

System panel and chemical tanks housed in a single cabinet.

System assembled in a wall cabinet with electrical panel, pipework and dosing pumps

Wall cabinet

Pipework, pumps and electrical panel in a wall cabinet with door.

Skid with two dosing pumps, PMMA cover and raised stainless steel frame

Skid with cover

Skid with raised stainless steel frame and protective PMMA cover.

Skid in a box with door, dosing pumps and chemical tanks

Skid in a box

Skid enclosed in a box with door, with the chemical tanks at the base.

Skid on a frame with doors, controller, dosing pumps and pipework

Skid on a frame

Skid on a frame with doors, pre-assembled and ready for connection.

Dosing station with the pump mounted on the chemical tank

On the tank

Dosing pump mounted directly on the tank: the most compact solution.

System wall-mounted in the plant room with dosing pumps and chemical tanks

In the plant room

Wall installation in the plant room, with the chemical tanks on the floor.

Pumps, controllers or components supplied by the customer can also be fitted, with custom dimensions, back panel and electrical panel. Dosing stations and skids →

Remote control

System remote control

The controllers support two-way remote access (read and write) through the web portal from a PC, tablet or smartphone: measurements can be viewed, set points, dosing and alarms changed, alarms received and logs downloaded. Alternatively, they can be integrated into your PLC via Modbus.

Ethernet

Connection to the web portal via network cable: measurements, set points, dosing and alarms accessible from a PC, tablet or smartphone.

Standard

Wi-Fi

Wireless connection to the web portal, with the same functions as the cable connection.

Standard

USB port

Download of the logged data to a USB memory stick, for archiving and analysis with a spreadsheet.

Standard
NIMBUS web portal for remote control of the systemsWeb portalPC, tablet and smartphone

Modbus RTU

Integration into your PLC via serial port.

Standard

Modbus TCP/IP

Integration into your PLC or SCADA via Ethernet network.

Standard

0-4/20 mA current loop output

Current signal proportional to the measured value, for remote monitoring or for controlling pumps and other instrumentation.

Standard

4G

Connection via the 4G network for installations without a local network, with alarm notification by SMS or e-mail.

Optional

Ethernet, Wi-Fi, USB, Modbus RTU, Modbus TCP/IP and 0-4/20 mA current loop outputs as standard; 4G modem optional.

The NIMBUS portal

A single account brings together all registered installations, each with its own devices: the web portal, free of charge and with no subscription, can be accessed from a PC, Mac, tablet or smartphone and allows every parameter to be both viewed and changed, with an encrypted connection and protected access.

The NIMBUS portal on monitor, laptop, tablet and smartphone

Overview

On a single screen: probe readings, chemical levels, pump activation thresholds and active alarms, with the status of installations and devices (normal, warning, alarm, standby, not connected).

Installation map

Installations appear on an interactive map with their status and open with a click; for each one, the local weather conditions and temperature are also shown.

History and charts

Archive of measurements and alarms, available for consultation at any time with charts and numerical reports exportable in Excel format.

Alarms and notifications

Alarm thresholds for readings, dosing, faulty probe and out-of-range readings, with notification by e-mail or SMS depending on the communication system; a warning is also issued when an installation remains disconnected beyond the set time.

Set points and dosing

Remote modification of the set points, of the dosing pump activation thresholds and of the corresponding hourly flow rate.

Inputs and outputs

Status of relays, pulse outputs, digital inputs and current outputs, with the name assigned to each connection.

Maintenance calendar

Tasks are scheduled by installation or by device and assigned to technicians; a reminder is sent by e-mail two days before the due date. Each task is shown as scheduled, due, overdue or completed.

Team and permissions

The main account has full access and creates the technicians’ accounts, each enabled only for the assigned installations and devices; the last login and activity of each technician are visible.

Reports and activity log

Reports on devices, tasks and technicians, downloadable in PDF or CSV with the customer’s logo; the log keeps the history of operations and disconnections.

Customisation

Logo, main colour and light or dark theme; the tiles on the main screen can be rearranged by dragging them. Two installations can be displayed side by side for comparison.

Guided registration

Each device is added through a guided procedure: the model is recognised automatically and associated with the installation, together with the technician to be contacted.

PLC integration

As an alternative to the portal, the Modbus RTU or TCP/IP port allows integration into the plant supervision system.

NIMBUS portal: Real-time readings, counters and timers
Real-time readings, counters and timers
NIMBUS portal: Free chlorine and temperature trends
Free chlorine and temperature trends
NIMBUS portal: Set point and operating mode of each channel
Set point and operating mode of each channel
NIMBUS portal: Status of relays, pulses, inputs and mA outputs
Status of relays, pulses, inputs and mA outputs

Technical advice

Describe the plant and the water flow rate to be treated: we will size the controller, probes, pumps and accessories.

Contact

Tell us about your plant

Call or write to us: a technician will reply with a tailored proposal of controllers, pumps, probes and accessories.

What do you need?
Please enter your name.
Please enter a valid email address.
Please enter your message.

Describe your plant: type, water volume or flow rate, parameters to be controlled.

You must accept the privacy notice to continue.