Skip to content
Systems for fire-fighting water tanks

WNpHCl

The WNpHCl controller measures pH and free chlorine and controls two integrated stepper-motor peristaltic pumps, one for the acid and one for the hypochlorite: a compact and quiet solution to keep the water of the fire-fighting tank disinfected, with Wi-Fi as standard.

  • pH and free chlorine
  • Two integrated peristaltic pumps
  • pH control priority
  • Wi-Fi as standard
WNpHCl
WNpHCl
Components

Basic components

WNpHCl controller

WNpHCl controller

It measures pH and free chlorine and controls two integrated stepper-motor peristaltic pumps, quiet and precise, one for the acid and one for the hypochlorite.

WNpHCl pump →
pH electrode

pH electrode

Combination electrode, 0 – 14 pH scale, with temperature compensation.

pH electrodes →
Closed amperometric cell

Closed amperometric cell

SCL cell with selective membrane: it measures free chlorine, compensating for pH and temperature.

SCL cells →
Flow-through probe holder

Flow-through probe holder

In PMMA, with sample flow rate adjustment and flow sensor, which stops dosing when there is no circulation.

Probe holders →
Injection lance

Injection lance

It introduces the product into the centre of the pipe, improving mixing; it can be withdrawn with the pipe under pressure.

Lances →
1

Sampling

The sampling pump sends the water from the tank to the probe holder; the water then returns to the tank.

2

pH priority

The controller first adjusts the pH and only then doses the hypochlorite, which works best when the pH is within the correct range.

3

Proportional dosing

The pumps progressively reduce their flow rate as the values approach the set points.

4

Alarms

Product levels, no flow in the probe holder, maximum dosing time and faulty probe.

Colour display

Colour-coded status indication

The colour of the display changes according to the operating status, so that an alarm can be recognised even from a distance.

Display Green

Green

Normal operation according to the set parameters, no active alarms.

Display Yellow

Yellow

Non-blocking alarm, for example waiting for an external signal.

Display Red

Red

Blocking alarm, for example the chemical in the tank running out.

Display White

White

Pump stopped by an external control signal (stand-by).

Technical data

Probe data sheet

pH electrode

EpHS
Pressure7 bar (3.5 bar)
ConnectionBNC
BodyEpoxy
Minimum conductivity100 µS
Temperature70 °C (80 °C)
Cable0.8 m
Diameter12 mm

All models: combination electrode, range 0 – 14 pH, resolution 0.01.

Closed amperometric cell

SCL3S/20
Measuring range0 – 20 mg/l
Resolution0.01
Free chlorineOrganic and inorganic
WaterFresh or salt
Electrodes2
Selective membrane●
Automatic compensationTemperature
Self-cleaning–
Operating pH5.5 – 9.5
Operating temperature5 – 45 °C
Operating pressure1 bar
Water flow30 l/h
Other systems

Fire-fighting water tanks

The requirements of the sector and the comparison with the other systems available.

Systems for fire-fighting water tanks →
Remote control

Remote control

Wi-Fi is standard: from the web portal, free of charge and with no subscription, you can read the measurements, change set points and dosing and receive alarm notifications, from a PC, tablet or smartphone.

NIMBUS web portal for remote control of the systems

Wi-Fi

Wireless connection to the web portal, with the same functions as the cable connection.

The NIMBUS portal

A single account brings together all registered installations, each with its own devices: the web portal, free of charge and with no subscription, can be accessed from a PC, Mac, tablet or smartphone and allows every parameter to be both viewed and changed, with an encrypted connection and protected access.

The NIMBUS portal on monitor, laptop, tablet and smartphone

Overview

On a single screen: probe readings, chemical levels, pump activation thresholds and active alarms, with the status of installations and devices (normal, warning, alarm, standby, not connected).

Installation map

Installations appear on an interactive map with their status and open with a click; for each one, the local weather conditions and temperature are also shown.

History and charts

Archive of measurements and alarms, available for consultation at any time with charts and numerical reports exportable in Excel format.

Alarms and notifications

Alarm thresholds for readings, dosing, faulty probe and out-of-range readings, with notification by e-mail or SMS depending on the communication system; a warning is also issued when an installation remains disconnected beyond the set time.

Set points and dosing

Remote modification of the set points, of the dosing pump activation thresholds and of the corresponding hourly flow rate.

Inputs and outputs

Status of relays, pulse outputs, digital inputs and current outputs, with the name assigned to each connection.

Maintenance calendar

Tasks are scheduled by installation or by device and assigned to technicians; a reminder is sent by e-mail two days before the due date. Each task is shown as scheduled, due, overdue or completed.

Team and permissions

The main account has full access and creates the technicians’ accounts, each enabled only for the assigned installations and devices; the last login and activity of each technician are visible.

Reports and activity log

Reports on devices, tasks and technicians, downloadable in PDF or CSV with the customer’s logo; the log keeps the history of operations and disconnections.

Customisation

Logo, main colour and light or dark theme; the tiles on the main screen can be rearranged by dragging them. Two installations can be displayed side by side for comparison.

Guided registration

Each device is added through a guided procedure: the model is recognised automatically and associated with the installation, together with the technician to be contacted.

NIMBUS portal: Real-time readings, counters and timers
Real-time readings, counters and timers
NIMBUS portal: Free chlorine and temperature trends
Free chlorine and temperature trends
NIMBUS portal: Set point and operating mode of each channel
Set point and operating mode of each channel
NIMBUS portal: Status of relays, pulses, inputs and mA outputs
Status of relays, pulses, inputs and mA outputs

Technical advice

Describe your plant and the flow rate of water to be treated: we will size the controller, pumps and accessories.

Contact

Tell us about your plant

Call or write to us: a technician will reply with a tailored proposal of controllers, pumps, probes and accessories.

What do you need?
Please enter your name.
Please enter a valid email address.
Please enter your message.

Describe your plant: type, water volume or flow rate, parameters to be controlled.

You must accept the privacy notice to continue.