WNpHCl Peroxide
With integrated pH and hydrogen peroxide measuring controllers.
- Proportional to pH
- Proportional to hydrogen peroxide
- Automatic pH dosing
- External constant
Swimming pool dosing pump with two integrated stepper motor peristaltic pumps, for the pH adjuster and for hydrogen peroxide, controlled by the measurements of both parameters. Hydrogen peroxide is measured with the SCL 9/200 closed amperometric cell, over a range of 0 to 200 mg/l, with pH and temperature compensation performed in the probe. The peristaltic drive is suitable for chemicals that release gas, such as peroxide.
With integrated pH and hydrogen peroxide measuring controllers.
When the run contact closes, the pump doses the set quantity of chemical.
The required pH value (SET POINT) is set: the pump measures the pH by means of a pH electrode and progressively reduces the injection frequency as the measured value approaches the set point, stopping when the SET POINT is reached.
Once the pool volume has been set, the pump automatically adjusts dosing according to the required pH (SET POINT), measured by means of a pH electrode: the injection frequency is progressively reduced as the measured value approaches the set point, until the pump stops when the SET POINT is reached.
The required concentration of free hydrogen peroxide in mg/l (SET POINT) is set: the pump measures it by means of a closed amperometric cell for peroxide and doses until the SET POINT is reached.
The flow rate is adjusted electronically by frequency, by varying the number of revolutions per minute of the motor. The exclusive AUTO DOSING function automatically configures system operation on the basis of the pool water volume.
The stepper motor and the control software deliver the product optimally with completely silent operation, a feature appreciated when dosing pH adjuster and disinfectant in swimming pools and hot tubs.

The tube is made of TPV, an elastomer compatible with most chemicals, which retains its elastic properties even after millions of compression cycles by the rollers.
The display colour changes with the operating status, so that an alarm can be recognised even from a distance. The setting screens of this model are shown below.
Normal operation according to the set parameters, no active alarms.
Non-blocking alarm, for example waiting for an external signal.
Blocking alarm, for example the chemical in the tank running out.
Pump stopped by an external control signal (stand-by).
Performance depends on the peristaltic tube installed: the 1.6 × 1.6 mm tube covers the lowest flow rates, the 4.8 × 1.6 mm tube flow rates up to 12 l/h. The tube set in the controller must match the one installed, because the AUTO DOSING function takes it into account when calculating the dosage.
Suitable for dosing most chemicals.
| Tube (mm) | Max pressure (bar) | Flow rate (l/h) | ml/rev | RPM |
|---|---|---|---|---|
| 1.6 × 1.6 | 2 | 0.018 – 1.8 | 0.3 | 1 – 100 |
| 4.8 × 1.6 | 2 | 0.12 – 12 | 2 | 1 – 100 |
| Specification | Value |
|---|---|
| Integrated pumps | 2 stepper motor peristaltic pumps, for the pH adjuster and for the disinfectant |
| Measuring range | 0 – 14 pH; hydrogen peroxide 0 – 200 mg/l |
| Temperature reading | 0 – 100 °C |
| Rotor speed | 1 – 100 RPM |
| Maximum pressure | 2 bar |
| Maximum chemical viscosity | 100 cP |
| Delayed dosing start | Up to 60 minutes |
| Power supply | 100 – 240 VAC, 50/60 Hz |
| Protection rating | IP54 |
| Component | Material |
|---|---|
| Pump body | PC/ABS |
| Cover | PC |
| Dust bushing | PEEK/PPS |
| Tube retainer and hose connectors | PVDF |
| Roller | POM (Delrin) |
| Long-life peristaltic tube | TPV |
The pump, with its built-in measuring instruments, is the core of the treatment system: the system page gives the composition, the installation diagram and the installation.
The WNpHCl Peroxide controller measures pH and hydrogen peroxide and controls two integrated stepper-motor peristaltic pumps, quiet and precise,, one for the pH corrector and one for the hydrogen peroxide; probe holder, measuring cell and sample filter are pre-assembled on a panel.
The system →In addition to dosing, the WN pumps also monitor the water: the messages mainly concern the process; in peristaltic pumps the condition of the tubes is also decisive.
Learn more: the pump does not prime and does not dose →| Message | Meaning | Action |
|---|---|---|
| LOW TANK | Chemical tank close to running out. | Check and restore the chemical level in the tank. |
| NO FLOW | The flow contact has stopped the pumps. | Check that there is water flow in the probe holder. |
| FEED LIMIT | Maximum dosing time exceeded without reaching the set point. | Check the pump flow rate and the actual supply of chemical. |
| PROBE FAIL | Probe reading unchanged for too long: the probe is probably damaged. | Check the probe, clean or recalibrate it; if the problem persists, replace it. |
| WAIT pH | pH has priority: the second dosing waits until the pH returns to the correct values. | Normal operating condition; to disable it, change the priority option. |
| DELAY | Dosing suspended: the restart delay countdown is in progress. | Normal operating condition; if not required, reduce the delay in the parameters. |
| POWER SUPPLY OUT OF RANGE | Supply voltage outside the permitted limits. | Check the mains voltage. |
| FEED ON · FEED OFF · OK | Normal operating status: pump dosing, pump stopped, or value at set point. | No action required. |
| WARNING under a channel | The tube of that pump has reached its wear limit (yellow display). | Replace the tube and reset the counter. |
| Calibration reminder | 90 days have passed since the last probe calibration (yellow display, the pump continues to operate). | Recalibrate the probe. |
Green display: normal operation; yellow: warning; red: alarm; white: stand-by. In the event of an alarm or warning, the details can be viewed by turning the knob to STATUS.
The MAINTENANCE menu records the revolutions and operating hours of motors and tubes: when a tube reaches its wear limit, a warning appears below the channel and the display turns yellow. The limits refer to 1 bar of back pressure, 23 °C and chemicals that are not particularly aggressive.
Switch off and disconnect the pump, close the valves and drain the liquid. Open the cover, remove the rotor cover disc and take out the slide with the worn tube; insert the new slide and bring the tube into position by turning the roller holder. Check by hand that it rotates freely, reassemble and carry out a dry test. If the roller holder is removed, the letter “A” must face the operator.
If a motor stops, the status screen shows the corresponding error code (from 1 to 13): by passing it on to our technical support service it is possible to identify immediately whether the problem concerns the power supply, wiring, temperature or communication.
Always enable the maximum dosing time alarm (0 – 100 minutes) and the blocked probe alarm (100 – 254 minutes), and set dosing to stop in the absence of flow: without these protections there is a risk of dangerous overdosing.
If the problem persists, contact us. Before sending the pump for servicing, empty the pump head of chemical and dry it.
According to the operating mode and the set parameters, the pump automatically adapts the injection frequency to ensure the required dosing.
Pump start and stop can be controlled remotely by means of a run/stop contact from a PLC or another source.
In the event of a fault, a volt-free contact is activated, configurable as normally open (N.O.) or normally closed (N.C.), to drive a visual or audible signalling device, send an SMS or report the event to a PLC.
The flow rate can be adjusted independently for each pump (or between the pump and the salt chlorinator), so that the correct quantities of pH adjuster and disinfectant are dosed according to the probe measurements.
One SET POINT dedicated to pH and one dedicated to the disinfectant (free chlorine, bromine, hydrogen peroxide or Redox).
Priority can be given to pH control, with disinfectant control starting only afterwards, which makes it more effective.
The pump is supplied with low-level probes for the tanks: when a chemical runs out, it shows the alarm on the display and activates the corresponding output.
A dedicated button allows the lines to be filled with the chemical to be dosed.
Vertical installation, or horizontal installation by means of a dedicated bracket.
In the absence of flow in the probe holder (circulation pump stopped), dosing is suspended and the alarm is triggered.
The WN pumps support two-way remote control: from the cloud portal, via Wi-Fi, Ethernet or 4G, settings can be changed, operation can be checked and alarms can be received, such as product depletion.
Allows connection to the NIMBUS cloud portal to change settings, check operation and receive alarms, such as the chemical running out.
Pump programming directly from a smartphone.
Web portalPC, tablet and smartphone
Allows connection to the NIMBUS cloud portal via network cable to change settings, check operation and receive alarms.
Allows connection to the NIMBUS cloud portal via the 4G network to change settings, check operation and receive alarms.
A single account brings together all registered installations, each with its own devices: the web portal, free of charge and with no subscription, can be accessed from a PC, Mac, tablet or smartphone and allows every parameter to be both viewed and changed, with an encrypted connection and protected access.
On a single screen: probe readings, chemical levels, pump activation thresholds and active alarms, with the status of installations and devices (normal, warning, alarm, standby, not connected).
Installations appear on an interactive map with their status and open with a click; for each one, the local weather conditions and temperature are also shown.
Archive of measurements and alarms, available for consultation at any time with charts and numerical reports exportable in Excel format.
Alarm thresholds for readings, dosing, faulty probe and out-of-range readings, with notification by e-mail or SMS depending on the communication system; a warning is also issued when an installation remains disconnected beyond the set time.
Remote modification of the set points, of the dosing pump activation thresholds and of the corresponding hourly flow rate.
Status of relays, pulse outputs, digital inputs and current outputs, with the name assigned to each connection.
Tasks are scheduled by installation or by device and assigned to technicians; a reminder is sent by e-mail two days before the due date. Each task is shown as scheduled, due, overdue or completed.
The main account has full access and creates the technicians’ accounts, each enabled only for the assigned installations and devices; the last login and activity of each technician are visible.
Reports on devices, tasks and technicians, downloadable in PDF or CSV with the customer’s logo; the log keeps the history of operations and disconnections.
Logo, main colour and light or dark theme; the tiles on the main screen can be rearranged by dragging them. Two installations can be displayed side by side for comparison.
Each device is added through a guided procedure: the model is recognised automatically and associated with the installation, together with the technician to be contacted.
Tell us about your application: our technical staff will recommend the most suitable model, configuration and accessories.
Call or write to us: a technician will reply with a tailored proposal of controllers, pumps, probes and accessories.