TMS Rh
With integrated Redox meter for control of the Redox potential (ORP).
- Proportional to Redox
- Automatic Redox dosing
Diaphragm dosing pump with a built-in Redox controller, for automatic measurement and control of the Redox potential (ORP) over the 0 – 1,000 mV range with flow rates up to 100 l/h; the electrode, ordered separately, connects directly to the pump. Display, level control and stand-by input are standard. A self-purging version and a P version for liquids up to 50,000 cP are also available.
The required Redox potential (ORP) (SET POINT) is set: the pump measures it by means of a Redox electrode and progressively reduces the injection frequency as the measured value approaches the set point, stopping when the SET POINT is reached.
Once the pool volume has been set, the pump automatically adjusts dosing according to the required Redox potential (ORP) (SET POINT), measured by means of a Redox electrode: the injection frequency is progressively reduced as the measured value approaches the set point, until the pump stops when the SET POINT is reached.
The pump code is made up of the model name and the performance: maximum pressure in bar as two digits followed by the flow rate in l/h (TMS Rh 0515 = 5 bar, 15 l/h). It is followed by the pump head code and the power supply code, listed in the tables at the end of this section. Performance varies with the working back pressure and with the characteristics of the chemical.
Suitable for most chemicals: the standard configuration for the most common applications.
| Code | Max pressure (bar) | Max flow rate (l/h) | Delivery tube (mm) | Suction tube (mm) | cc per stroke |
|---|---|---|---|---|---|
| TMS Rh 2005 | 20 | 5 | 4 x 6 | 4 x 6 | 0.7 |
| TMS Rh 0515 | 5 | 15 | 6 x 8 | 6 x 8 | 2.1 |
| TMS Rh 0420 | 4 | 20 | 6 x 8 | 6 x 8 | 2.8 |
| TMS Rh 0330 | 3 | 30 | 8 x 10 | 8 x 12 | 4.2 |
| TMS Rh 0150 | 1 | 50 | 8 x 10 | 8 x 12 | 7 |
| TMS Rh 00100 | 0 | 100 | 12 x 18 (braided PVC) | 12 x 18 (braided PVC) | 14 |
Required with chemicals that release gas (e.g. peroxides), to prevent the pump from becoming air-locked.
| Code | Max pressure (bar) | Max flow rate (l/h) | Delivery tube (mm) | Suction tube (mm) | cc per stroke |
|---|---|---|---|---|---|
| TMSA Rh 203.2 | 20 | 3.2 | 4 x 6 | 4 x 6 | 0.44 |
| TMSA Rh 0510 | 5 | 10 | 6 x 8 | 6 x 8 | 1.39 |
| TMSA Rh 0413 | 4 | 13 | 6 x 8 | 6 x 8 | 1.8 |
| TMSA Rh 0320 | 3 | 20 | 8 x 10 | 8 x 12 | 2.78 |
| TMSA Rh 0135 | 1 | 35 | 8 x 10 | 8 x 12 | 4.86 |
For chemicals with a viscosity between 8,000 and 50,000 cP.
| Code | Max pressure (bar) | Max flow rate (l/h) | Delivery tube (mm) | Suction tube (mm) | cc per stroke |
|---|---|---|---|---|---|
| TMSP Rh 0601 | 6 | 1 | 16 x 22 | 20 x 27 | 0.14 |
| TMSP Rh 0403 | 4 | 3 | 16 x 22 | 20 x 27 | 0.42 |
| TMSP Rh 0208 | 2 | 8 | 16 x 22 | 20 x 27 | 1.2 |
| TMSP Rh 0120 | 1 | 20 | 16 x 22 | 20 x 27 | 2.8 |
| TMSP Rh 0025 | 0 | 25 | 16 x 22 | 20 x 27 | 3.5 |
Nominal flow rate measured with water at room temperature. The P version is supplied without injection valve, level probe and foot filter.
| Specification | Value |
|---|---|
| Strokes | Up to 120 per minute; up to 150 per minute on the P 0601 model |
| Maximum chemical viscosity | 100 cP; 8,000 cP with the $ pump head; 50,000 cP in the P version |
| Average power draw at maximum flow rate (manual and automatic air bleed) | 27 W at 230 VAC and 21 W at 115 VAC; on models 0515 and 0510, 15 W at 115 VAC and 14 W at 24 VAC and 24 VDC |
| Protection rating | IP65 |
| Noise level | 62.0 dB(A); 57.4 dB(A) in the P version |
| Weight | 5.7 kg; 5 kg in the P version (5.7 kg for model 0120) |
| Housing | PP |
| Mounting | Vertical, or horizontal with the dedicated bracket |
| Ambient temperature | 0 – 45 °C; 10 – 45 °C in the P version |
| Product temperature | 0 – 50 °C |
| Transport and storage temperature | −10 – 50 °C |
| Relative humidity | 85 % up to 40 °C, 70 % at 45 °C, non-condensing |
| Maximum altitude | 2,000 m a.s.l. |
| Installation category | II |
| Pollution degree | 2 |
| Head | Material | O-rings | Valves | Balls | Delivery tube | Suction tube | Max viscosity (cP) |
|---|---|---|---|---|---|---|---|
| K | PVDF | FKM | PVDF | Ceramic | PVDF | PVC | 100 |
| P | PVDF | EPDM | PVDF | Ceramic | PVDF | PVC | 100 |
| W | PVDF | NBR | PVDF | Ceramic | PVDF | PVC | 100 |
| V | PP | FKM | – | Ceramic | PE | PVC | 100 |
| D | PP | EPDM | – | Ceramic | PE | PVC | 100 |
| T | PVDF | FKM + PTFE | PVDF | Ceramic | PVDF | PVC | 100 |
| A | PMMA | FKM | PVDF | Ceramic | PVDF | PVC | 100 |
| Z | AISI 316L | FKM | AISI 316L | AISI 316L | – | – | 100 |
| $ | PMMA | FKM | PP | Stainless steel, Hastelloy spring | PE | PVC | 8,000 |
| B (P version) | PMMA | FKM | PP | PTFE, Hastelloy spring | PVC | PVC | 50,000 |
PTFE diaphragm for all pump heads. The tube size may vary with the pump head material; with low-viscosity liquids the $ pump head may reduce the flow rate.
| Code | Power supply |
|---|---|
| 00 | 230 VAC, Schuko plug |
| 0S | 230 VAC, Australian plug |
| 01 | 230 VAC, no plug |
| 03 | 115 VAC, US plug |
| 04 | 24 VAC, no plug |
| 05 | 12 VDC (some models only) |
| 07 | 24 VDC |
In the P version only codes 00, 0S, 01 and 03 are available.
Suitable for most acids, for peroxides and for sodium hypochlorite (chlorine).
Suitable for sodium hydroxide (caustic soda).
Suitable for peracetic acid and sodium hydroxide.
Suitable for medium and high viscosity substances.
In addition to the standard configuration, versions dedicated to particular applications are available; the performance of each is given in the technical data. The pages by application compare the suitable pumps of all the series.
Self-venting pump head, required with chemicals that release gas (e.g. sodium hypochlorite and peroxides): it vents the gas and prevents the pump from locking.
PMMA pump head for high-viscosity liquids, from 8,000 to 50,000 cP.
For dosing large quantities of chemicals in industrial applications: up to 230 l/h.
The most frequent causes of malfunction and the corrective actions to check before contacting technical support.
Learn more: the pump does not prime and does not dose →| Message | Meaning | Action |
|---|---|---|
| LOW LEVEL | Product running low in the tank. | Refill the tank. |
| LOW VOLT | The mains voltage is lower than the rated voltage. | Check the power supply. |
| HIGH VOL | The mains voltage is higher than the rated voltage. | Check the power supply. |
| DOSING · AL OFF | The maximum dosing time alarm (1 – 100 minutes) has been triggered. | In STOP mode the pump remains stopped: press any key to restart it and check why the value does not reach the set point. |
| CALIB ERROR | Probe calibration failed. | Repeat the calibration, strictly following the procedure. |
| STAND-BY | The pump is completing the waiting phase. | No action required. |
| DATA SAVED | The data have been saved. | No action required. |
Adjustment is linear between 30 and 100%: below 30% the actual flow rate may differ from the expected one and must therefore be checked.
Connect all the tubing, open the bleed valve and set the adjustment to 100%; start the pump and close the bleed valve as soon as the chemical comes out. With viscous liquids the operation can be assisted with a 20 cc syringe applied to the bleed port.
With the pump switched off, hold down both arrow keys and restore power: LOAD DEFAULT appears and the programming is reset to the factory values (password 0000).
If the problem persists, contact us. Before sending the pump for servicing, empty the pump head of chemical and dry it.
According to the operating mode and the set parameters, the pump automatically adapts the injection frequency to ensure the required dosing.
The integrated LCD display allows the pump to be programmed and its operating status to be monitored at all times.
The pump is supplied with a low-level probe for the tank: when the chemical runs out, it shows the alarm on the display and activates the corresponding output.
Pump start and stop can be controlled remotely by means of a run/stop contact from a PLC or another source.
In the event of a fault, a volt-free contact is activated, configurable as normally open (N.O.) or normally closed (N.C.), to drive a visual or audible signalling device, send an SMS or report the event to a PLC.
A dedicated button allows the lines to be filled with the chemical to be dosed.
Vertical installation, or horizontal installation by means of a dedicated bracket.