TMS MF
Constant dosing or dosing proportional to 0-4/20 mA current loop or 0-10 V signals or to a pulse-output water meter.
- Digital constant
- Multiply
- Divide
- PPM
- Millilitres per quintal (100 kg)
- Percentage
- Batch
- mA
- Volt
- External constant
- Pause / work
Multifunction diaphragm dosing pump with display, for constant dosing or dosing proportional to a pulse-output water meter or to 0-4/20 mA and 0-10 V signals, in ppm, as a percentage and in batches. Level control, stand-by input, flow sensor input and alarm output are standard. Besides the standard version, up to 100 l/h, a self-purging version, a P version for liquids up to 50,000 cP and a compressed air version up to 230 l/h are available.
Constant dosing or dosing proportional to 0-4/20 mA current loop or 0-10 V signals or to a pulse-output water meter.
TMS MF PPMMA pump head for viscous liquids up to 50,000 cP.
Pump head: PVDF, PP, PMMA or AISI 316L
The pump doses at a constant frequency, determined by the SPH (strokes/hour), SPM (strokes/minute) or LPH (litres/hour) values set during programming.
When the run contact closes, the pump doses the set quantity of chemical.
The pump runs the programmed cycle: during the WORK time it doses the set quantity of chemical; during the PAUSE time dosing is suspended.
The pulses from the pulse-output water meter are multiplied by the set factor.
The pulses from the pulse-output water meter are divided by the set factor.
Dosing is calculated from the pulses of the pulse-output water meter and the set PPM value; the concentration of the chemical and the volume per stroke can be programmed.
Dosing is calculated from the pulses of the pulse-output water meter and the set MLQ value (millilitres per quintal, i.e. per 100 kg).
Dosing is calculated from the pulses of the pulse-output water meter and the set percentage (%).
A pulse from an external contact starts the dosing of the set quantity; pause and work cycles can be programmed.
The 0-4/20 mA current loop signal controls dosing proportionally, between the set minimum and maximum values.
The 0-10 V voltage signal controls dosing proportionally, between the set minimum and maximum values.
The pump code is made up of the model name and the performance: maximum pressure in bar as two digits followed by the flow rate in l/h (TMS MF 0515 = 5 bar, 15 l/h). It is followed by the pump head code and the power supply code, listed in the tables at the end of this section. Performance varies with the working back pressure and with the characteristics of the chemical.
Suitable for most chemicals: the standard configuration for the most common applications.
| Code | Max pressure (bar) | Max flow rate (l/h) | Delivery tube (mm) | Suction tube (mm) | cc per stroke |
|---|---|---|---|---|---|
| TMS MF 2005 | 20 | 5 | 4 x 6 | 4 x 6 | 0.7 |
| TMS MF 0515 | 5 | 15 | 6 x 8 | 6 x 8 | 2.1 |
| TMS MF 0420 | 4 | 20 | 6 x 8 | 6 x 8 | 2.8 |
| TMS MF 0330 | 3 | 30 | 8 x 10 | 8 x 12 | 4.2 |
| TMS MF 0150 | 1 | 50 | 8 x 10 | 8 x 12 | 7 |
| TMS MF 00100 | 0 | 100 | 12 x 18 (braided PVC) | 12 x 18 (braided PVC) | 14 |
Required with chemicals that release gas (e.g. peroxides), to prevent the pump from becoming air-locked.
| Code | Max pressure (bar) | Max flow rate (l/h) | Delivery tube (mm) | Suction tube (mm) | cc per stroke |
|---|---|---|---|---|---|
| TMSA MF 203.2 | 20 | 3.2 | 4 x 6 | 4 x 6 | 0.44 |
| TMSA MF 0510 | 5 | 10 | 6 x 8 | 6 x 8 | 1.39 |
| TMSA MF 0413 | 4 | 13 | 6 x 8 | 6 x 8 | 1.8 |
| TMSA MF 0320 | 3 | 20 | 8 x 10 | 8 x 12 | 2.78 |
| TMSA MF 0135 | 1 | 35 | 8 x 10 | 8 x 12 | 4.86 |
For chemicals with a viscosity between 8,000 and 50,000 cP.
| Code | Max pressure (bar) | Max flow rate (l/h) | Delivery tube (mm) | Suction tube (mm) | cc per stroke |
|---|---|---|---|---|---|
| TMSP MF 0601 | 6 | 1 | 16 x 22 | 20 x 27 | 0.14 |
| TMSP MF 0403 | 4 | 3 | 16 x 22 | 20 x 27 | 0.42 |
| TMSP MF 0208 | 2 | 8 | 16 x 22 | 20 x 27 | 1.2 |
| TMSP MF 0120 | 1 | 20 | 16 x 22 | 20 x 27 | 2.8 |
| TMSP MF 0025 | 0 | 25 | 16 x 22 | 20 x 27 | 3.5 |
Nominal flow rate measured with water at room temperature. The P version is supplied without injection valve, level probe and foot filter.
For dosing large quantities of chemical in industrial applications.
| Code | Max pressure (bar) | Max flow rate (l/h) | Delivery tube (mm) | Suction tube (mm) | cc per stroke |
|---|---|---|---|---|---|
| T AC MF 1050 | 10 | 50 | 8 x 10 | 8 x 12 | 7 |
| T AC MF 05150 | 5 | 150 | 13 x 16 | 12 x 18 | 20.8 |
| T AC MF 00230 | 0 | 230 | 13 x 16 | 12 x 18 | 32 |
| Specification | Value |
|---|---|
| Strokes | Up to 120 per minute; up to 150 per minute on the P 0601 model |
| Maximum chemical viscosity | 100 cP; 8,000 cP with the $ pump head; 50,000 cP in the P version |
| Average power draw at maximum flow rate (manual and automatic air bleed) | 27 W at 230 VAC and 21 W at 115 VAC; on models 0515 and 0510, 15 W at 115 VAC and 14 W at 24 VAC and 24 VDC |
| Protection rating | IP65; IP54 in the compressed air version |
| Noise level | 62.0 dB(A); 57.4 dB(A) in the P version; 78.3 dB(A) in the compressed air version |
| Weight | 5.7 kg; 5 kg in the P version (5.7 kg for model 0120); 9 kg in the compressed air version |
| Housing | PP |
| Mounting | Vertical, or horizontal with the dedicated bracket |
| Ambient temperature | 0 – 45 °C; 10 – 45 °C in the P version |
| Product temperature | 0 – 50 °C |
| Transport and storage temperature | −10 – 50 °C |
| Relative humidity | 85 % up to 40 °C, 70 % at 45 °C, non-condensing |
| Maximum altitude | 2,000 m a.s.l. |
| Installation category | II |
| Pollution degree | 2 |
| Compressed air (AC version) | 6 – 10 bar, free of lubricant and condensate |
| Head | Material | O-rings | Valves | Balls | Delivery tube | Suction tube | Max viscosity (cP) |
|---|---|---|---|---|---|---|---|
| K | PVDF | FKM | PVDF | Ceramic | PVDF | PVC | 100 |
| P | PVDF | EPDM | PVDF | Ceramic | PVDF | PVC | 100 |
| W | PVDF | NBR | PVDF | Ceramic | PVDF | PVC | 100 |
| V | PP | FKM | – | Ceramic | PE | PVC | 100 |
| D | PP | EPDM | – | Ceramic | PE | PVC | 100 |
| T | PVDF | FKM + PTFE | PVDF | Ceramic | PVDF | PVC | 100 |
| A | PMMA | FKM | PVDF | Ceramic | PVDF | PVC | 100 |
| Z | AISI 316L | FKM | AISI 316L | AISI 316L | – | – | 100 |
| $ | PMMA | FKM | PP | Stainless steel, Hastelloy spring | PE | PVC | 8,000 |
| B (P version) | PMMA | FKM | PP | PTFE, Hastelloy spring | PVC | PVC | 50,000 |
PTFE diaphragm for all pump heads. The tube size may vary with the pump head material; with low-viscosity liquids the $ pump head may reduce the flow rate.
| Code | Power supply |
|---|---|
| 00 | 230 VAC, Schuko plug |
| 0S | 230 VAC, Australian plug |
| 01 | 230 VAC, no plug |
| 03 | 115 VAC, US plug |
| 04 | 24 VAC, no plug |
| 05 | 12 VDC (some models only) |
| 07 | 24 VDC |
In the P version only codes 00, 0S, 01 and 03 are available.
Suitable for most acids, for peroxides and for sodium hypochlorite (chlorine).
Suitable for sodium hydroxide (caustic soda).
Suitable for peracetic acid and sodium hydroxide.
Suitable for medium and high viscosity substances.
In addition to the standard configuration, versions dedicated to particular applications are available; the performance of each is given in the technical data. The pages by application compare the suitable pumps of all the series.
Self-venting pump head, required with chemicals that release gas (e.g. sodium hypochlorite and peroxides): it vents the gas and prevents the pump from locking.
PMMA pump head for high-viscosity liquids, from 8,000 to 50,000 cP.
For dosing large quantities of chemicals in industrial applications: up to 230 l/h.
The most frequent causes of malfunction and the corrective actions to check before contacting technical support.
Learn more: the pump does not prime and does not dose →| Message | Meaning | Action |
|---|---|---|
| ALARM LEVEL | Chemical in the tank has run out. | Restore the chemical level in the tank. |
| ALARM SEFL | The flow sensor has detected an excessive number of empty strokes, or the automatic re-priming has failed. | Check the SEFL sensor, prime the pump manually, then switch it off and on again. |
| OVER FLOW | The required operating frequency exceeds the rated value. | Check the set parameters and the pump flow rate, then switch it off and on again. |
| ALARM STROKE | The set flow rate exceeds the rated value. | Check the set parameters and the flow rate, then switch the pump off and on again. |
| ALARM POWER | Supply voltage outside the permitted limits. | Check that the voltage matches the rating plate data, then switch the pump off and on again. |
| ALARM BATCH | Batch dosing interrupted by a change of state of the external contact. | Check that the connected contact matches the pump configuration, then switch off and on again. |
| INPUT OPEN | No input signal in mA or Volt mode. | Check the external signal and its connection. |
| ERROR DATA | Inconsistent set values. | Check the values again; if they are correct and the error persists, the pump is undersized for the required dosing. |
| ERROR MEM | Error in the settings memory. | Restore the factory values with the LOAD DEFAULT procedure. |
| WRONG ENTRY | Invalid setting, for example the same value for the signal minimum and maximum. | Set distinct, correct values. |
| Incorrect password | The password entered does not match the stored one. | If it has been lost, restore the value 0000 with the RESET PASSWORD procedure. |
The # symbol on the display indicates one or more active alarms, which can be viewed on the ALARM QTY screen.
Adjustment is linear between 30 and 100%: below 30% the actual flow rate may differ from the expected one and must therefore be checked.
Connect all the tubing, open the bleed valve and set the adjustment to 100%; start the pump and close the bleed valve as soon as the chemical comes out. With viscous liquids the operation can be assisted with a 20 cc syringe applied to the bleed port.
With the pump switched off, hold down both arrow keys and restore power: LOAD DEFAULT appears and the programming is reset to the factory values (password 0000).
If the problem persists, contact us. Before sending the pump for servicing, empty the pump head of chemical and dry it.
According to the operating mode and the set parameters, the pump automatically adapts the injection frequency to ensure the required dosing.
The integrated LCD display allows the pump to be programmed and its operating status to be monitored at all times.
The pump is supplied with a low-level probe for the tank: when the chemical runs out, it shows the alarm on the display and activates the corresponding output.
Pump start and stop can be controlled remotely by means of a run/stop contact from a PLC or another source.
A flow sensor can be connected to check every single injection: if one or more injections are missed, the pump performs an automatic re-priming and recovers the lost injections; if this fails, it activates the alarm output.
In the event of a fault, a volt-free contact is activated, configurable as normally open (N.O.) or normally closed (N.C.), to drive a visual or audible signalling device, send an SMS or report the event to a PLC.
A dedicated button allows the lines to be filled with the chemical to be dosed.
Vertical installation, or horizontal installation by means of a dedicated bracket.