Skip to content
Solenoid dosing pump

AMS pH

Diaphragm dosing pump with an integrated instrument for measuring and automatically controlling pH, over the range from 0 to 14 pH, for flow rates up to 60 l/h and back pressures up to 25 bar. The pH electrode is not included and is chosen to suit the installation; display, level control and stand-by input are standard.

  • Integrated pH meter
  • 0 – 14 pH range
  • Up to 25 bar
  • Up to 60 l/h
AMS pH dosing pump
60l/hMaximum flow rate
25barMaximum pressure
23Configurations
50,000cPMaximum viscosity
The model

AMS pH

AMS pH dosing pump
Integrated pH meter

AMS pH

With integrated pH meter for automatic pH control.

  • Proportional to pH
  • Automatic pH dosing
Compatible components
EpHS EpHSpH electrode

Pump head: PVDF, PP, PMMA or AISI 316L

Operation

Dosing modes

Proportional to pH

The required pH value (SET POINT) is set: the pump measures the pH by means of a pH electrode and progressively reduces the injection frequency as the measured value approaches the set point, stopping when the SET POINT is reached.

Automatic pH dosing

Once the pool volume has been set, the pump automatically adjusts dosing according to the required pH (SET POINT), measured by means of a pH electrode: the injection frequency is progressively reduced as the measured value approaches the set point, until the pump stops when the SET POINT is reached.

Technical data

Performance and configurations

The pump code is made up of the model name and the performance: maximum pressure in bar as two digits followed by the flow rate in l/h (AMS pH 2505 = 25 bar, 5 l/h). It is followed by the pump head code and the power supply code, listed in the tables at the end of this section. Performance varies with the working back pressure and with the characteristics of the chemical.

Manual air bleed

Suitable for most chemicals: the standard configuration for the most common applications.

CodeMax pressure (bar)Max flow rate (l/h)Delivery tube (mm)Suction tube (mm)cc per stroke
AMS pH 25052554 x 64 x 60.7
AMS pH 151015104 x 64 x 61.4
AMS pH 101510156 x 86 x 82.08
AMS pH 07207206 x 86 x 82.8
AMS pH 03403408 x 108 x 125.6
AMS pH 02602608 x 108 x 127.7

Tube sizes may vary with the pump head material. The cc per stroke refer to the mechanical stroke adjustment set at 100%.

Automatic air bleed

Required with chemicals that release gas (e.g. peroxides), to prevent the pump from becoming air-locked.

CodeMax pressure (bar)Max flow rate (l/h)Delivery tube (mm)Suction tube (mm)
AMSA pH 253.2253.24 x 64 x 6
AMSA pH 15061564 x 64 x 6
AMSA pH 101010106 x 86 x 8
AMSA pH 07137136 x 86 x 8
AMSA pH 03303308 x 108 x 12
AMSA pH 02382388 x 108 x 12

Medium-viscosity liquids

For chemicals with a viscosity between 100 and 8,000 cP.

CodeMax pressure (bar)Max flow rate (l/h)
AMS pH LPV 2505255
AMS pH LPV 15101510
AMS pH LPV 10151015
AMS pH LPV 0720720
AMS pH LPV 0340340
AMS pH LPV 0260260

Nominal flow rate measured with water at room temperature. The pump head is made of PMMA with manual air bleed; the package includes a 3/4” injection valve, a 16 x 22 PVC suction tube and an 8 x 12 PE delivery tube.

High-viscosity liquids

For chemicals with a viscosity between 8,000 and 50,000 cP.

CodeMax pressure (bar)Max flow rate (l/h)cc per stroke
AMS P pH 0802820.28
AMS P pH 0604640.56
AMS P pH 04104101.4
AMS P pH 04254253.5
AMS P pH 01401405.6

Nominal flow rate measured with water at room temperature: with viscous liquids the flow rate is lower. 20 x 27 suction tube and 16 x 22 delivery tube, 1” suction valve and 3/4” delivery valve; this version is supplied without injection valve, level probe and foot filter.

Technical specifications

SpecificationValue
Strokes per minuteFrom 1 stroke per hour to 120 strokes per minute
Linearity of the mechanical adjustmentFrom 30 to 100%
Average power draw at maximum flow rate42 W at 230 VAC; 24 W at 115 VAC
Peak current2.5 A
Maximum chemical viscosity100 cP; 8,000 cP with the pump head for viscous liquids
Maximum suction height1.5 m
Ambient temperature10 – 45 °C
Chemical temperature0 – 50 °C
Transport and storage temperature10 – 50 °C
Relative humidity85% up to 40 °C, 70% at 45 °C, non-condensing
Maximum altitude2,000 m
Protection ratingIP65
Noise level57.4 dB(A)
Weight9 kg
HousingPP
MountingHorizontal, floor or wall

Values for the standard version and the automatic air bleed version.

Viscous liquid version

SpecificationAMS P pH
Maximum chemical viscosity50,000 cP
Strokes per minuteFrom 1 stroke per hour to 120 strokes per minute
Average power draw at maximum flow rate42 W at 230 VAC
Compressed air supply—
Ambient temperature10 – 45 °C
Transport and storage temperature10 – 50 °C
Noise level78.3 dB(A)
Weight9 kg
Electrical power suppliesCodes 00, 0S, 01 and 03

Pump head codes

CodePump headSealsValvesBallsMax viscosity (cP)
KPVDFFKM BPVDFCeramic100
PPVDFEPDMPVDFCeramic100
YPVDFNBRPVDFCeramic100
VPPFKM BPPCeramic100
DPPEPDMPPCeramic100
JPVDFFKM B + PTFEPVDFCeramic100
APMMAFKM BPVDFCeramic100
ZAISI 316LFKM BAISI 316LAISI 316L100
$PMMAFKM BPPStainless steel, Hastelloy spring8,000
B (AMS P)PMMAFKM BPPPTFE, Hastelloy spring50,000

PTFE diaphragm in all versions. The delivery tube is PVDF, or PE with PP pump heads and with code $; the suction tube is PVC. The stainless steel pump head (Z) is supplied without tubes.

Power supply codes

CodePower supply
00230 VAC, Schuko plug
0S230 VAC, Australian plug
01230 VAC, no plug
03115 VAC, US plug
0424 VAC, no plug
0512 VDC (some models only)
0724 VDC

Voltage range and fuses

Power supplyVoltage rangeFuse
230 VAC190 – 265 VAC1.25 A
115 VAC90 – 135 VAC1.6 A
24 VAC20 – 32 VAC6.3 A
12 VDC10 – 16 VDC5 A

Supplied with

  • PVDF foot filter with level probe
  • 0.3 bar PVDF injection valve
  • Delivery, suction and drain tubes (2 m each)
  • Input signal cable (2.5 m)
  • Alarm and stand-by cable (2 m)
  • 5 × 20 time-delay fuse
  • Mounting kit
  • Operating manual

Pump head materials

Pump head in PVDF

PVDF

Suitable for most acids, for peroxides and for sodium hypochlorite (chlorine).

Pump head in PP

PP

Suitable for sodium hydroxide (caustic soda).

Pump head in AISI 316L

AISI 316L

Suitable for peracetic acid and sodium hydroxide.

Pump head in PMMA

PMMA

Suitable for medium and high viscosity substances.

Learn more: chemical compatibility of materials →

Special versions

Special versions

In addition to the standard configuration, versions dedicated to particular applications are available; the performance of each is given in the technical data. The pages by application compare the suitable pumps of all the series.

AMSA Series

AMSA Series

Self-venting pump head, required with chemicals that release gas (e.g. sodium hypochlorite and peroxides): it vents the gas and prevents the pump from locking.

Technical support

Troubleshooting and error messages

The most frequent causes of malfunction and the corrective actions to check before contacting technical support.

Learn more: the pump does not prime and does not dose →

If the pump…

The pump strokes normally, but the chemical is not dosed
  • Air in the hydraulic circuitCheck fittings and tubing, tighten any loose ones and bleed the air.
  • Suction tube emptiedThe pump has lost its prime: repeat the priming procedure.
  • Foot filter cloggedRemove the lance or filter from the tank and clean it.
  • Gas released by the chemicalOpen the bleed valve to discharge the gas; if this recurs, fit a self-bleeding pump head.
No strokes, or weak and damped stroke
  • Valve balls blocked by crystallisation of the chemicalClean the valves and run the pump with 2 – 3 litres of water instead of the chemical; if the problem persists, replace the valves.
  • Injection valve cloggedReplace the injection valve.
The pump does not switch on
  • No power supplyCheck the mains connection and that the voltage matches the rated value.
  • Protection fuse blownReplace the fuse with one of the same rating.
  • Faulty circuit boardThe board must be replaced: contact our technical support service.

Flow rate between 30 and 100%

Adjustment is linear between 30 and 100%: below 30% the actual flow rate may differ from the expected one and must therefore be checked.

Priming

Connect all the tubing, open the bleed valve and set the adjustment to 100%; start the pump and close the bleed valve as soon as the chemical comes out. With viscous liquids the operation can be assisted with a 20 cc syringe applied to the bleed port.

If the problem persists, contact us. Before sending the pump for servicing, empty the pump head of chemical and dry it.

Summary

Main features

Electronic flow rate adjustment

According to the operating mode and the set parameters, the pump automatically adapts the injection frequency to ensure the required dosing.

Mechanical flow rate adjustment

The knob reduces the stroke length of the diaphragm, i.e. the volume of each injection and, consequently, the maximum flow rate. This offers two advantages:
Linear dosing: a high number of small-volume injections promotes mixing of the chemical into the water flow and avoids concentration peaks.
Accuracy at low dosing rates: with a 10 l/h pump required to dose 1 l/h, reducing the stroke length to 50% brings the maximum flow rate down to 5 l/h and doubles the injection frequency. Particularly suitable in combination with the pulse-output water meter.

Digital display

The integrated LCD display allows the pump to be programmed and its operating status to be monitored at all times.

Level control

The pump is supplied with a low-level probe for the tank: when the chemical runs out, it shows the alarm on the display and activates the corresponding output.

Stand-by

Pump start and stop can be controlled remotely by means of a run/stop contact from a PLC or another source.

Alarm output

In the event of a fault, a volt-free contact is activated, configurable as normally open (N.O.) or normally closed (N.C.), to drive a visual or audible signalling device, send an SMS or report the event to a PLC.

Priming button

A dedicated button allows the lines to be filled with the chemical to be dosed.

Versatile mounting

Horizontal installation, or vertical installation by means of a dedicated bracket.

Technical advice

Tell us about your application: our technical staff will recommend the most suitable model, configuration and accessories.

Contact

Tell us about your plant

Call or write to us: a technician will reply with a tailored proposal of controllers, pumps, probes and accessories.

What do you need?
Please enter your name.
Please enter a valid email address.
Please enter your message.

Describe your plant: type, water volume or flow rate, parameters to be controlled.

You must accept the privacy notice to continue.