AMS CO
Basic model for constant dosing without external controls.
- Constant
- Constant with divider
Diaphragm dosing pump for constant dosing, the basic model of the AMS series: the flow rate is set on the pump by adjusting the injection frequency electronically, with a divider down to 1/10, and the volume of each injection mechanically, without external signals.
Basic model for constant dosing without external controls.
Pump head: PVDF, PP, PMMA or AISI 316L
The pump doses at a constant injection frequency, proportional to the flow rate percentage set with the analogue selector (0 – 100%).
Operation similar to constant dosing, with the selector adjustable between 0 and 10%: the maximum flow rate is reduced to as little as 1/10 of the rated value.
The pump code is made up of the model name and the performance: maximum pressure in bar as two digits followed by the flow rate in l/h (AMS CO 2505 = 25 bar, 5 l/h). It is followed by the pump head code and the power supply code, listed in the tables at the end of this section. Performance varies with the working back pressure and with the characteristics of the chemical.
Suitable for most chemicals: the standard configuration for the most common applications.
| Code | Max pressure (bar) | Max flow rate (l/h) | Delivery tube (mm) | Suction tube (mm) | cc per stroke |
|---|---|---|---|---|---|
| AMS CO 2505 | 25 | 5 | 4 x 6 | 4 x 6 | 0.7 |
| AMS CO 1510 | 15 | 10 | 4 x 6 | 4 x 6 | 1.4 |
| AMS CO 1015 | 10 | 15 | 6 x 8 | 6 x 8 | 2.08 |
| AMS CO 0720 | 7 | 20 | 6 x 8 | 6 x 8 | 2.8 |
| AMS CO 0340 | 3 | 40 | 8 x 10 | 8 x 12 | 5.6 |
| AMS CO 0260 | 2 | 60 | 8 x 10 | 8 x 12 | 7.7 |
Tube sizes may vary with the pump head material. The cc per stroke refer to the mechanical stroke adjustment set at 100%.
Required with chemicals that release gas (e.g. peroxides), to prevent the pump from becoming air-locked.
| Code | Max pressure (bar) | Max flow rate (l/h) | Delivery tube (mm) | Suction tube (mm) |
|---|---|---|---|---|
| AMSA CO 253.2 | 25 | 3.2 | 4 x 6 | 4 x 6 |
| AMSA CO 1506 | 15 | 6 | 4 x 6 | 4 x 6 |
| AMSA CO 1010 | 10 | 10 | 6 x 8 | 6 x 8 |
| AMSA CO 0713 | 7 | 13 | 6 x 8 | 6 x 8 |
| AMSA CO 0330 | 3 | 30 | 8 x 10 | 8 x 12 |
| AMSA CO 0238 | 2 | 38 | 8 x 10 | 8 x 12 |
For chemicals with a viscosity between 100 and 8,000 cP.
| Code | Max pressure (bar) | Max flow rate (l/h) |
|---|---|---|
| AMS CO LPV 2505 | 25 | 5 |
| AMS CO LPV 1510 | 15 | 10 |
| AMS CO LPV 1015 | 10 | 15 |
| AMS CO LPV 0720 | 7 | 20 |
| AMS CO LPV 0340 | 3 | 40 |
| AMS CO LPV 0260 | 2 | 60 |
Nominal flow rate measured with water at room temperature. The pump head is made of PMMA with manual air bleed; the package includes a 3/4” injection valve, a 16 x 22 PVC suction tube and an 8 x 12 PE delivery tube.
For chemicals with a viscosity between 8,000 and 50,000 cP.
| Code | Max pressure (bar) | Max flow rate (l/h) | cc per stroke |
|---|---|---|---|
| AMS P CO 0802 | 8 | 2 | 0.28 |
| AMS P CO 0604 | 6 | 4 | 0.56 |
| AMS P CO 0410 | 4 | 10 | 1.4 |
| AMS P CO 0425 | 4 | 25 | 3.5 |
| AMS P CO 0140 | 1 | 40 | 5.6 |
Nominal flow rate measured with water at room temperature: with viscous liquids the flow rate is lower. 20 x 27 suction tube and 16 x 22 delivery tube, 1” suction valve and 3/4” delivery valve; this version is supplied without injection valve, level probe and foot filter.
For dosing large quantities of chemical in industrial applications.
| Code | Max pressure (bar) | Max flow rate (l/h) | Delivery tube (mm) | Suction tube (mm) | cc per stroke | Air consumption (l/min) |
|---|---|---|---|---|---|---|
| AMS AC CO 1050 | 10 | 50 | 8 x 10 | 8 x 12 | 6.94 | 20 |
| AMS AC CO 05140 | 5 | 140 | 13 x 16 | 12 x 18 | 19.44 | 30 |
| AMS AC CO 00220 | 0 | 220 | 13 x 16 | 12 x 18 | 30.56 | 30 |
The pump requires both an electrical supply and compressed air at 6 to 10 bar, free of lubricant and condensate; the air tube connection is 6 x 8. The pump head is made of PVDF with manual air bleed.
| Specification | Value |
|---|---|
| Strokes per minute | 12 – 120 |
| Linearity of the mechanical adjustment | From 30 to 100% |
| Average power draw at maximum flow rate | 42 W at 230 VAC; 24 W at 115 VAC |
| Peak current | 2.5 A |
| Maximum chemical viscosity | 100 cP; 8,000 cP with the pump head for viscous liquids |
| Maximum suction height | 1.5 m |
| Ambient temperature | 10 – 45 °C |
| Chemical temperature | 0 – 50 °C |
| Transport and storage temperature | 10 – 50 °C |
| Relative humidity | 85% up to 40 °C, 70% at 45 °C, non-condensing |
| Maximum altitude | 2,000 m |
| Protection rating | IP65 |
| Noise level | 57.4 dB(A) |
| Weight | 9 kg |
| Housing | PP |
| Mounting | Horizontal, floor or wall |
Values for the standard version and the automatic air bleed version.
| Specification | AMS P CO | AMS AC CO |
|---|---|---|
| Maximum chemical viscosity | 50,000 cP | 100 cP |
| Strokes per minute | 12 – 120 | 12 – 120 |
| Average power draw at maximum flow rate | 42 W at 230 VAC | 1 W |
| Compressed air supply | — | 6 – 10 bar |
| Ambient temperature | 10 – 45 °C | 0 – 45 °C |
| Transport and storage temperature | 10 – 50 °C | −10 – 50 °C |
| Noise level | 78.3 dB(A) | 78.3 dB(A) |
| Weight | 9 kg | 4.5 kg |
| Electrical power supplies | Codes 00, 0S, 01 and 03 | All codes in the table |
| Code | Pump head | Seals | Valves | Balls | Max viscosity (cP) |
|---|---|---|---|---|---|
| K | PVDF | FKM B | PVDF | Ceramic | 100 |
| P | PVDF | EPDM | PVDF | Ceramic | 100 |
| Y | PVDF | NBR | PVDF | Ceramic | 100 |
| V | PP | FKM B | PP | Ceramic | 100 |
| D | PP | EPDM | PP | Ceramic | 100 |
| J | PVDF | FKM B + PTFE | PVDF | Ceramic | 100 |
| A | PMMA | FKM B | PVDF | Ceramic | 100 |
| Z | AISI 316L | FKM B | AISI 316L | AISI 316L | 100 |
| $ | PMMA | FKM B | PP | Stainless steel, Hastelloy spring | 8,000 |
| B (AMS P) | PMMA | FKM B | PP | PTFE, Hastelloy spring | 50,000 |
PTFE diaphragm in all versions. The delivery tube is PVDF, or PE with PP pump heads and with code $; the suction tube is PVC. The stainless steel pump head (Z) is supplied without tubes.
| Code | Pump head | Seals | Valves | Balls |
|---|---|---|---|---|
| K | PVDF | FKM B | PVDF | Ceramic |
| P | PVDF | EPDM | PVDF | Ceramic |
| W | PVDF | NBR | PVDF | Ceramic |
| T | PVDF | FKM B + PTFE | PVDF | Ceramic |
| A | PMMA | FKM B | PP | Ceramic |
| Z | AISI 316L | FKM B | AISI 316L | AISI 316L |
PTFE diaphragm; maximum chemical viscosity 100 cP.
| Code | Power supply |
|---|---|
| 00 | 230 VAC, Schuko plug |
| 0S | 230 VAC, Australian plug |
| 01 | 230 VAC, no plug |
| 03 | 115 VAC, US plug |
| 04 | 24 VAC, no plug |
| 05 | 12 VDC (some models only) |
| 07 | 24 VDC |
| Power supply | Voltage range | Fuse |
|---|---|---|
| 230 VAC | 190 – 265 VAC | 1.25 A |
| 115 VAC | 90 – 135 VAC | 1.6 A |
| 24 VAC | 20 – 32 VAC | 6.3 A |
| 12 VDC | 10 – 16 VDC | 5 A |
Suitable for most acids, for peroxides and for sodium hypochlorite (chlorine).
Suitable for sodium hydroxide (caustic soda).
Suitable for peracetic acid and sodium hydroxide.
Suitable for medium and high viscosity substances.
In addition to the standard configuration, versions dedicated to particular applications are available; the performance of each is given in the technical data. The pages by application compare the suitable pumps of all the series.
Self-venting pump head, required with chemicals that release gas (e.g. sodium hypochlorite and peroxides): it vents the gas and prevents the pump from locking.
For chemicals with a viscosity between 100 and 8,000 cP.
PMMA pump head for high-viscosity liquids, from 8,000 to 50,000 cP.
For dosing large quantities of chemicals in industrial applications: up to 220 l/h.
The most frequent causes of malfunction and the corrective actions to check before contacting technical support.
Learn more: the pump does not prime and does not dose →Adjustment is linear between 30 and 100%: below 30% the actual flow rate may differ from the expected one and must therefore be checked.
Connect all the tubing, open the bleed valve and set the adjustment to 100%; start the pump and close the bleed valve as soon as the chemical comes out. With viscous liquids the operation can be assisted with a 20 cc syringe applied to the bleed port.
If the problem persists, contact us. Before sending the pump for servicing, empty the pump head of chemical and dry it.
According to the operating mode and the set parameters, the pump automatically adapts the injection frequency to ensure the required dosing.
The knob reduces the stroke length of the diaphragm, i.e. the volume of each injection and, consequently, the maximum flow rate. This offers two advantages:
Linear dosing: a high number of small-volume injections promotes mixing of the chemical into the water flow and avoids concentration peaks.
Accuracy at low dosing rates: with a 10 l/h pump required to dose 1 l/h, reducing the stroke length to 50% brings the maximum flow rate down to 5 l/h and doubles the injection frequency. Particularly suitable in combination with the pulse-output water meter.
A dedicated button allows the lines to be filled with the chemical to be dosed.
Horizontal installation, or vertical installation by means of a dedicated bracket.
Tell us about your application: our technical staff will recommend the most suitable model, configuration and accessories.
Call or write to us: a technician will reply with a tailored proposal of controllers, pumps, probes and accessories.