LDsCL controller
It acquires the measurement from the cell and, through its outputs, starts and stops the ozone generator according to the set point.
LDsCL for ozone →The system continuously measures the ozone dissolved in the water and regulates its concentration. Since ozone is generated on site and decomposes rapidly, the controller does not drive a dosing pump but starts and stops the ozone generator until the set point is reached.
The ozone system has no dosing pump: the controller acts directly on the ozone generator of the plant.
It acquires the measurement from the cell and, through its outputs, starts and stops the ozone generator according to the set point.
LDsCL for ozone →
The selective membrane allows ozone alone to be measured; the cell is available in two ranges and automatically compensates for temperature.
SCL10 cell →
It holds the cell in the flow of sample water, with flow rate adjustment and flow control, which suspends regulation when there is no circulation.
Probe holders →
Installed upstream of the probe holder, it retains the impurities that would foul the membrane of the cell.
NFIL filter →The concentration of ozone to be maintained in the water (set point) is entered; the system maintains it automatically and continuously.

The sample water flows through the filter and the probe holder, where the SCL10 cell measures the dissolved ozone; the water then returns to the circuit or the tank.
When the concentration falls below the set point, the controller starts the ozone generator; once the set point is reached, it stops it.
When there is no flow in the probe holder the measurement is not representative: regulation is suspended until circulation is restored.
The controller signals out-of-range readings, a faulty probe and the absence of flow.
Ozone disinfects at the moment of contact with the water and decomposes rapidly into oxygen, without leaving a residual: where the distribution network must be protected, it is combined with a disinfectant with a residual effect, such as chlorine.
In drinking water treatment plants, measuring the dissolved ozone allows production to be regulated according to the concentration actually present.
Learn more: drinking water →
In the processing and washing water of food plants, the ozone concentration remains controlled and documented.
Learn more: food industry →
To maintain the residual disinfectant along the network, free chlorine is measured and dosed with an LDsCL controller fitted with the free chlorine cell.
Residual chlorine system →The cell works in the flow-through probe holder, connected to the circuit in a bypass line: the sample water is taken from the pipe or the tank, flows through the filter and the probe holder and returns to the storage tank, to the suction of the recirculation pumps or to drain.
The sample is taken with a T-fitting on the pipe carrying the water to be analysed.
Probe holders →
For installation in the electrical panel of the plant, ozone can also be measured with the JA PRO panel-mount controllers and the DIN Digital DIN-rail controllers.

Measuring ranges, resolution, characteristics of the SCL10 cell, inputs, outputs and connections are given in the controller data sheet.
The controllers support two-way remote access (read and write) through the web portal from a PC, tablet or smartphone: measurements can be viewed, set points, dosing and alarms changed, alarms received and logs downloaded. Alternatively, they can be integrated into your PLC via Modbus.
Connection to the web portal via network cable: measurements, set points, dosing and alarms accessible from a PC, tablet or smartphone.
Wireless connection to the web portal, with the same functions as the cable connection.
Connection via the 4G network for installations without a local network, with alarm notification by SMS or e-mail.
Web portalPC, tablet and smartphone
Integration into your PLC via serial port.
Current signal proportional to the measured value, for remote monitoring or for controlling pumps and other instrumentation.
Download of the logged data to a USB memory stick, for archiving and analysis with a spreadsheet.
One communication type at a time: Ethernet, Wi-Fi, 4G or Modbus RTU (built into the BASIC versions, optional on the PLUS versions). 0-4/20 mA current loop outputs standard on the PLUS versions, optional on the BASIC versions; meter input on the PLUS versions only.
A single account brings together all registered installations, each with its own devices: the web portal, free of charge and with no subscription, can be accessed from a PC, Mac, tablet or smartphone and allows every parameter to be both viewed and changed, with an encrypted connection and protected access.
On a single screen: probe readings, chemical levels, pump activation thresholds and active alarms, with the status of installations and devices (normal, warning, alarm, standby, not connected).
Installations appear on an interactive map with their status and open with a click; for each one, the local weather conditions and temperature are also shown.
Archive of measurements and alarms, available for consultation at any time with charts and numerical reports exportable in Excel format.
Alarm thresholds for readings, dosing, faulty probe and out-of-range readings, with notification by e-mail or SMS depending on the communication system; a warning is also issued when an installation remains disconnected beyond the set time.
Remote modification of the set points, of the dosing pump activation thresholds and of the corresponding hourly flow rate.
Status of relays, pulse outputs, digital inputs and current outputs, with the name assigned to each connection.
Tasks are scheduled by installation or by device and assigned to technicians; a reminder is sent by e-mail two days before the due date. Each task is shown as scheduled, due, overdue or completed.
The main account has full access and creates the technicians’ accounts, each enabled only for the assigned installations and devices; the last login and activity of each technician are visible.
Reports on devices, tasks and technicians, downloadable in PDF or CSV with the customer’s logo; the log keeps the history of operations and disconnections.
Logo, main colour and light or dark theme; the tiles on the main screen can be rearranged by dragging them. Two installations can be displayed side by side for comparison.
Each device is added through a guided procedure: the model is recognised automatically and associated with the installation, together with the technician to be contacted.
As an alternative to the portal, the Modbus RTU port allows integration into the plant supervision system.
Describe your plant, the ozone generator installed and the concentration to be maintained: we will propose the controller, cell and accessories.
Call or write to us: a technician will reply with a tailored proposal of controllers, pumps, probes and accessories.