Skip to content
Search

Search the site

96 pages for “cat=sonde&q=q%3Dq%2Bq%2Bcan%2Bsystem%2B2bq%2B2bq%2Bcooling%2Btowers”
No page contains all the words: results containing some of them.

Probes

ETRC2 tracers

Fluorometer for industrial water systems that require continuous monitoring of tracers (fluorescent dyes): it combines reliability and high performance with minimal maintenance. Range 0 – 300 ppb Sensitivity 1 ppb Response in 5 seconds In-line installation wit …

Probes

SCL cells › Self-cleaning cells for hot water

For Legionella control systems and cooling towers, SCL18 (free chlorine) and SCL17 (chlorine dioxide) are available. Legionella: risks, regulations and treatments → Three electrodes, no membrane The cell has no semi-permeable membrane and features three measur …

Also in: Bromine · Data sheet

Probes

E‑CORR corrosion › The two versions

E-CORR COLD For cold water: evaporative cooling towers, cooling towers and closed cooling circuits. AISI 304 stainless steel body with protection against electromagnetic interference; three O-rings on the body allow the insertion depth to be adjusted. Sample t …

Probes

Conductivity

Conductive conductivity probes for cooling towers, boilers, fertigation and process water. Four series, with graphite, stainless steel or platinum electrodes, and automatic temperature compensation on all models. From 0 – 20 µS to 0 – 200 mS NTC 10K or PT100 c …

Probes

ETORB2 turbidity › Measuring principle and self-cleaning

… nephelometric principle, with automatic temperature compensation. The range can be set to 0/40, 0/400 or 0/4,000 NTU. 2 Self-cleaning A water jet (maximum 1 bar), controlled by the controller according to the set programme, cleans the optical measuring window.

Also in: Data sheet

Probes

Inductive conductivity › Data sheet

… Measuring range 0.3 – 3 mS 0.3 – 30 mS 0.3 – 300 mS 0.3 – 10 mS Measuring system Inductive Inductive Body PEEK PEEK Mounting In-line / by-pass / immersion In-line / by-pass / immersion Temperature compensation PT100 PT100 Operating temperature 1 – 85 °C (100 ° …

Probes

ECL free chlorine › Data sheet

… Redox (PG13.5) Temperature, pH, Redox Temperature – – All models: amperometric system, range 0 – 10 mg/l, resolution 0.01, organic and inorganic free chlorine, operating temperature 1 – 40 °C, pressure 0.4 – 5 bar, water flow 40 l/h.

Probes

Redox electrodes › High linearity

… chlorine concentrations of drinking water. Glass body, range ± 1,500 mV; it can be fitted with water-jet or air-jet self-cleaning.

Probes

EOLUM dissolved oxygen › Data sheet

EOLUM Measuring range 0 – 20 mg/l Resolution 0.01 Measuring system Fluorescence Automatic compensation Temperature and pressure Operating temperature −5 / +50 °C Operating pressure 10 bar Body Stainless steel

Contact

Tell us about your plant

Call or write to us: a technician will reply with a tailored proposal of controllers, pumps, probes and accessories.

What do you need?
Please enter your name.
Please enter a valid email address.
Please enter your message.

Describe your plant: type, water volume or flow rate, parameters to be controlled.

You must accept the privacy notice to continue.