Skip to content
Solenoid dosing pump

TMS DC

Digital diaphragm dosing pump for constant dosing up to 100 l/h, set on the display in litres per hour or in strokes per minute. The stand-by input allows the pump to be stopped and restarted by an external contact; level control and alarm output are standard. A self-purging version and a P version for liquids up to 50,000 cP are also available.

  • Digital constant dosing
  • Stand-by input
  • Up to 20 bar
  • Up to 100 l/h
TMS DC dosing pump
100l/hMaximum flow rate
20barMaximum pressure
16Configurations
50,000cPMaximum viscosity (P version)
The model

TMS DC

TMS DC dosing pump
Constant with remote control

TMS DC

Constant dosing (l/h or strokes) with the option of remote control via an external contact.

  • Digital constant

Pump head: PVDF, PP, PMMA or AISI 316L

Operation

Dosing modes

Digital constant

The pump doses at a constant frequency, determined by the SPH (strokes/hour), SPM (strokes/minute) or LPH (litres/hour) values set during programming.

Technical data

Performance and configurations

The pump code is made up of the model name and the performance: maximum pressure in bar as two digits followed by the flow rate in l/h (TMS DC 0515 = 5 bar, 15 l/h). It is followed by the pump head code and the power supply code, listed in the tables at the end of this section. Performance varies with the working back pressure and with the characteristics of the chemical.

Manual air bleed

Suitable for most chemicals: the standard configuration for the most common applications.

CodeMax pressure (bar)Max flow rate (l/h)Delivery tube (mm)Suction tube (mm)cc per stroke
TMS DC 20052054 x 64 x 60.7
TMS DC 05155156 x 86 x 82.1
TMS DC 04204206 x 86 x 82.8
TMS DC 03303308 x 108 x 124.2
TMS DC 01501508 x 108 x 127
TMS DC 00100010012 x 18 (braided PVC)12 x 18 (braided PVC)14

Automatic air bleed

Required with chemicals that release gas (e.g. peroxides), to prevent the pump from becoming air-locked.

CodeMax pressure (bar)Max flow rate (l/h)Delivery tube (mm)Suction tube (mm)cc per stroke
TMSA DC 203.2203.24 x 64 x 60.44
TMSA DC 05105106 x 86 x 81.39
TMSA DC 04134136 x 86 x 81.8
TMSA DC 03203208 x 108 x 122.78
TMSA DC 01351358 x 108 x 124.86

High-viscosity liquids

For chemicals with a viscosity between 8,000 and 50,000 cP.

CodeMax pressure (bar)Max flow rate (l/h)Delivery tube (mm)Suction tube (mm)cc per stroke
TMSP DC 06016116 x 2220 x 270.14
TMSP DC 04034316 x 2220 x 270.42
TMSP DC 02082816 x 2220 x 271.2
TMSP DC 012012016 x 2220 x 272.8
TMSP DC 002502516 x 2220 x 273.5

Nominal flow rate measured with water at room temperature. The P version is supplied without injection valve, level probe and foot filter.

Technical specifications

SpecificationValue
StrokesUp to 120 per minute; up to 150 per minute on the P 0601 model
Maximum chemical viscosity100 cP; 8,000 cP with the $ pump head; 50,000 cP in the P version
Average power draw at maximum flow rate (manual and automatic air bleed)27 W at 230 VAC and 21 W at 115 VAC; on models 0515 and 0510, 15 W at 115 VAC and 14 W at 24 VAC and 24 VDC
Protection ratingIP65
Noise level62.0 dB(A); 57.4 dB(A) in the P version
Weight5.7 kg; 5 kg in the P version (5.7 kg for model 0120)
HousingPP
MountingVertical, or horizontal with the dedicated bracket
Ambient temperature0 – 45 °C; 10 – 45 °C in the P version
Product temperature0 – 50 °C
Transport and storage temperature−10 – 50 °C
Relative humidity85 % up to 40 °C, 70 % at 45 °C, non-condensing
Maximum altitude2,000 m a.s.l.
Installation categoryII
Pollution degree2

Pump head codes

HeadMaterialO-ringsValvesBallsDelivery tubeSuction tubeMax viscosity (cP)
KPVDFFKMPVDFCeramicPVDFPVC100
PPVDFEPDMPVDFCeramicPVDFPVC100
WPVDFNBRPVDFCeramicPVDFPVC100
VPPFKM–CeramicPEPVC100
DPPEPDM–CeramicPEPVC100
TPVDFFKM + PTFEPVDFCeramicPVDFPVC100
APMMAFKMPVDFCeramicPVDFPVC100
ZAISI 316LFKMAISI 316LAISI 316L––100
$PMMAFKMPPStainless steel, Hastelloy springPEPVC8,000
B (P version)PMMAFKMPPPTFE, Hastelloy springPVCPVC50,000

PTFE diaphragm for all pump heads. The tube size may vary with the pump head material; with low-viscosity liquids the $ pump head may reduce the flow rate.

Power supply codes

CodePower supply
00230 VAC, Schuko plug
0S230 VAC, Australian plug
01230 VAC, no plug
03115 VAC, US plug
0424 VAC, no plug
0512 VDC (some models only)
0724 VDC

In the P version only codes 00, 0S, 01 and 03 are available.

Supplied with

  • Level probe with PVDF axial foot filter
  • Delivery, suction and drain tubes (2 m each)
  • Stand-by and alarm signal cable (2.5 m)
  • 5 × 20 time-delay fuse
  • Mounting kit (wall plugs and screws)
  • Operating manual

Pump head materials

Pump head in PVDF

PVDF

Suitable for most acids, for peroxides and for sodium hypochlorite (chlorine).

Pump head in PP

PP

Suitable for sodium hydroxide (caustic soda).

Pump head in AISI 316L

AISI 316L

Suitable for peracetic acid and sodium hydroxide.

Pump head in PMMA

PMMA

Suitable for medium and high viscosity substances.

Learn more: chemical compatibility of materials →

Special versions

Special versions

In addition to the standard configuration, versions dedicated to particular applications are available; the performance of each is given in the technical data. The pages by application compare the suitable pumps of all the series.

TA and TMSA Series

TA and TMSA Series

Self-venting pump head, required with chemicals that release gas (e.g. sodium hypochlorite and peroxides): it vents the gas and prevents the pump from locking.

Technical support

Troubleshooting and error messages

The most frequent causes of malfunction and the corrective actions to check before contacting technical support.

Learn more: the pump does not prime and does not dose →

If the pump…

The pump strokes normally, but the chemical is not dosed
  • Air in the hydraulic circuitCheck fittings and tubing, tighten any loose ones and bleed the air.
  • Suction tube emptiedThe pump has lost its prime: repeat the priming procedure.
  • Foot filter cloggedRemove the lance or filter from the tank and clean it.
  • Gas released by the chemicalOpen the bleed valve to discharge the gas; if this recurs, fit a self-bleeding pump head.
No strokes, or weak and damped stroke
  • Valve balls blocked by crystallisation of the chemicalClean the valves and run the pump with 2 – 3 litres of water instead of the chemical; if the problem persists, replace the valves.
  • Injection valve cloggedReplace the injection valve.
The pump does not switch on
  • No power supplyCheck the mains connection and that the voltage matches the rated value.
  • Protection fuse blownReplace the fuse with one of the same rating.
  • Faulty circuit boardThe board must be replaced: contact our technical support service.

Display of the TMS DC

MessageMeaningAction
ALARM LEVELChemical tank empty.Refill the tank.
ALARM STD-BYPump stopped by the stand-by signal.Normal condition: the pump restarts when the enable signal is restored.
ALARM POWERThe power supply is outside the permitted values (180 – 260 VAC).Check the mains voltage.
ALARM STROKEThe set flow rate exceeds the rated flow rate.Correct the settings.
ERROR MEMError in the settings memory.Restore the factory values with the LOAD DEFAULT procedure.
ERROR DATAThe values entered are not consistent.Check the values; if they are correct and the error persists, the pump is undersized.

Flow rate between 30 and 100%

Adjustment is linear between 30 and 100%: below 30% the actual flow rate may differ from the expected one and must therefore be checked.

Priming

Connect all the tubing, open the bleed valve and set the adjustment to 100%; start the pump and close the bleed valve as soon as the chemical comes out. With viscous liquids the operation can be assisted with a 20 cc syringe applied to the bleed port.

Factory settings

With the pump switched off, hold down both arrow keys and restore power: LOAD DEFAULT appears and the programming is reset to the factory values (password 0000).

If the problem persists, contact us. Before sending the pump for servicing, empty the pump head of chemical and dry it.

Summary

Main features

Electronic flow rate adjustment

According to the operating mode and the set parameters, the pump automatically adapts the injection frequency to ensure the required dosing.

Digital display

The integrated LCD display allows the pump to be programmed and its operating status to be monitored at all times.

Level control

The pump is supplied with a low-level probe for the tank: when the chemical runs out, it shows the alarm on the display and activates the corresponding output.

Stand-by

Pump start and stop can be controlled remotely by means of a run/stop contact from a PLC or another source.

Alarm output

In the event of a fault, a volt-free contact is activated, configurable as normally open (N.O.) or normally closed (N.C.), to drive a visual or audible signalling device, send an SMS or report the event to a PLC.

Priming button

A dedicated button allows the lines to be filled with the chemical to be dosed.

Versatile mounting

Vertical installation, or horizontal installation by means of a dedicated bracket.

Technical advice

Tell us about your application: our technical staff will recommend the most suitable model, configuration and accessories.

Contact

Tell us about your plant

Call or write to us: a technician will reply with a tailored proposal of controllers, pumps, probes and accessories.

What do you need?
Please enter your name.
Please enter a valid email address.
Please enter your message.

Describe your plant: type, water volume or flow rate, parameters to be controlled.

You must accept the privacy notice to continue.