Skip to content
Solenoid dosing pump

TCL

Diaphragm dosing pump for constant dosing up to 100 l/h, with tank level control: when the chemical falls below the minimum level, the probe supplied as standard stops the pump and the red LED signals the alarm. The flow rate is adjusted electronically through the stroke frequency, with a 1/10 divider. A self-purging version and a compressed air version up to 230 l/h are also available.

  • Level probe as standard
  • 1/10 divider
  • Up to 20 bar
  • Up to 230 l/h with compressed air
TCL dosing pump
230l/hMaximum flow rate
20barMaximum pressure
14Configurations
120/minMaximum strokes
The model

TCL

TCL dosing pump
Constant with level control

TCL

For constant dosing, with input for tank level control.

  • Constant
  • Constant with divider

Pump head: PVDF, PP, PMMA or AISI 316L

Operation

Dosing modes

Constant

The pump doses at a constant injection frequency, proportional to the flow rate percentage set with the analogue selector (0 – 100%).

Constant with divider

Operation similar to constant dosing, with the selector adjustable between 0 and 10%: the maximum flow rate is reduced to as little as 1/10 of the rated value.

Technical data

Performance and configurations

The pump code is made up of the model name and the performance: maximum pressure in bar as two digits followed by the flow rate in l/h (TCL 0515 = 5 bar, 15 l/h). It is followed by the pump head code and the power supply code, listed in the tables at the end of this section. Performance varies with the working back pressure and with the characteristics of the chemical.

Manual air bleed

Suitable for most chemicals: the standard configuration for the most common applications.

CodeMax pressure (bar)Max flow rate (l/h)Delivery tube (mm)Suction tube (mm)cc per stroke
TCL 20052054 x 64 x 60.7
TCL 05155156 x 86 x 82.1
TCL 04204206 x 86 x 82.8
TCL 03303308 x 108 x 124.2
TCL 01501508 x 108 x 127
TCL 00100010012 x 18 (braided PVC)12 x 18 (braided PVC)14

Automatic air bleed

Required with chemicals that release gas (e.g. peroxides), to prevent the pump from becoming air-locked.

CodeMax pressure (bar)Max flow rate (l/h)Delivery tube (mm)Suction tube (mm)cc per stroke
TA CL 203.2203.24 x 64 x 60.44
TA CL 05105106 x 86 x 81.39
TA CL 04134136 x 86 x 81.8
TA CL 03203208 x 108 x 122.78
TA CL 01351358 x 108 x 124.86

Compressed air

For dosing large quantities of chemical in industrial applications.

CodeMax pressure (bar)Max flow rate (l/h)Delivery tube (mm)Suction tube (mm)cc per stroke
T AC CL 105010508 x 108 x 127
T AC CL 05150515013 x 1612 x 1820.8
T AC CL 00230023013 x 1612 x 1832

Technical specifications

SpecificationValue
StrokesFrom 12 to 120 per minute
Maximum chemical viscosity100 cP; 8,000 cP with the $ pump head
Average power draw at maximum flow rate (manual and automatic air bleed)27 W at 230 VAC and 21 W at 115 VAC; on models 0515 and 0510, 15 W at 115 VAC and 14 W at 24 VAC and 24 VDC
Protection ratingIP65; IP54 in the compressed air version
Noise level62.0 dB(A); 78.3 dB(A) in the compressed air version
Weight5.7 kg; 9 kg in the compressed air version
HousingPP
MountingVertical, or horizontal with the dedicated bracket
Ambient temperature0 – 45 °C
Product temperature0 – 50 °C
Transport and storage temperature−10 – 50 °C
Relative humidity85 % up to 40 °C, 70 % at 45 °C, non-condensing
Maximum altitude2,000 m a.s.l.
Installation categoryII
Pollution degree2
Compressed air (AC version)6 – 10 bar, free of lubricant and condensate

Pump head codes

HeadMaterialO-ringsValvesBallsDelivery tubeSuction tubeMax viscosity (cP)
KPVDFFKMPVDFCeramicPVDFPVC100
PPVDFEPDMPVDFCeramicPVDFPVC100
WPVDFNBRPVDFCeramicPVDFPVC100
VPPFKM–CeramicPEPVC100
DPPEPDM–CeramicPEPVC100
TPVDFFKM + PTFEPVDFCeramicPVDFPVC100
APMMAFKMPPCeramicPVDFPVC100
ZAISI 316LFKMAISI 316LAISI 316L––100
$PMMAFKMPPStainless steel, Hastelloy springPEPVC8,000

PTFE diaphragm for all pump heads. The tube size may vary with the pump head material; with low-viscosity liquids the $ pump head may reduce the flow rate.

Power supply codes

CodePower supply
00230 VAC, Schuko plug
0S230 VAC, Australian plug
01230 VAC, no plug
03115 VAC, US plug
0424 VAC, no plug
0512 VDC (some models only)
0724 VDC

Supplied with

  • Level probe with PVDF axial foot filter
  • Delivery, suction and drain tubes (2 m each)
  • 5 × 20 time-delay fuse
  • Mounting kit (wall plugs and screws)
  • Operating manual

Pump head materials

Pump head in PVDF

PVDF

Suitable for most acids, for peroxides and for sodium hypochlorite (chlorine).

Pump head in PP

PP

Suitable for sodium hydroxide (caustic soda).

Pump head in AISI 316L

AISI 316L

Suitable for peracetic acid and sodium hydroxide.

Pump head in PMMA

PMMA

Suitable for medium and high viscosity substances.

Learn more: chemical compatibility of materials →

Special versions

Special versions

In addition to the standard configuration, versions dedicated to particular applications are available; the performance of each is given in the technical data. The pages by application compare the suitable pumps of all the series.

TA and TMSA Series

TA and TMSA Series

Self-venting pump head, required with chemicals that release gas (e.g. sodium hypochlorite and peroxides): it vents the gas and prevents the pump from locking.

Technical support

Troubleshooting and error messages

The most frequent causes of malfunction and the corrective actions to check before contacting technical support.

Learn more: the pump does not prime and does not dose →

If the pump…

The pump strokes normally, but the chemical is not dosed
  • Air in the hydraulic circuitCheck fittings and tubing, tighten any loose ones and bleed the air.
  • Suction tube emptiedThe pump has lost its prime: repeat the priming procedure.
  • Foot filter cloggedRemove the lance or filter from the tank and clean it.
  • Gas released by the chemicalOpen the bleed valve to discharge the gas; if this recurs, fit a self-bleeding pump head.
No strokes, or weak and damped stroke
  • Valve balls blocked by crystallisation of the chemicalClean the valves and run the pump with 2 – 3 litres of water instead of the chemical; if the problem persists, replace the valves.
  • Injection valve cloggedReplace the injection valve.
The pump does not switch on
  • No power supplyCheck the mains connection and that the voltage matches the rated value.
  • Protection fuse blownReplace the fuse with one of the same rating.
  • Faulty circuit boardThe board must be replaced: contact our technical support service.

LEDs of the T models

LEDMeaningAction
3 flashes per secondMains voltage below the rated value.Check the power supply.
2 flashes per secondMains voltage above the rated value.Check the power supply.
1 flash every 2 secondsPump OFF, powered.No action required.
On, goes off at each strokePump running.No action required.
On, goes off every 2 secondsPump in divide mode (frequency reduced by a factor of 10).No action required.
Steady red (two-colour LED)Chemical below the minimum level: the pump stops.Restore the chemical level in the tank.
Green, flashing every second (two-colour LED)Supply voltage out of range.Check that the mains voltage matches the rated value.

Flow rate between 30 and 100%

Adjustment is linear between 30 and 100%: below 30% the actual flow rate may differ from the expected one and must therefore be checked.

Priming

Connect all the tubing, open the bleed valve and set the adjustment to 100%; start the pump and close the bleed valve as soon as the chemical comes out. With viscous liquids the operation can be assisted with a 20 cc syringe applied to the bleed port.

Factory settings

With the pump switched off, hold down both arrow keys and restore power: LOAD DEFAULT appears and the programming is reset to the factory values (password 0000).

If the problem persists, contact us. Before sending the pump for servicing, empty the pump head of chemical and dry it.

Summary

Main features

Electronic flow rate adjustment

According to the operating mode and the set parameters, the pump automatically adapts the injection frequency to ensure the required dosing.

Level control

The pump is supplied with a low-level probe for the tank: when the chemical runs out, it shows the alarm on the display and activates the corresponding output.

Priming button

A dedicated button allows the lines to be filled with the chemical to be dosed.

Versatile mounting

Vertical installation, or horizontal installation by means of a dedicated bracket.

Technical advice

Tell us about your application: our technical staff will recommend the most suitable model, configuration and accessories.

Contact

Tell us about your plant

Call or write to us: a technician will reply with a tailored proposal of controllers, pumps, probes and accessories.

What do you need?
Please enter your name.
Please enter a valid email address.
Please enter your message.

Describe your plant: type, water volume or flow rate, parameters to be controlled.

You must accept the privacy notice to continue.