TCL
For constant dosing, with input for tank level control.
- Constant
- Constant with divider
Diaphragm dosing pump for constant dosing up to 100 l/h, with tank level control: when the chemical falls below the minimum level, the probe supplied as standard stops the pump and the red LED signals the alarm. The flow rate is adjusted electronically through the stroke frequency, with a 1/10 divider. A self-purging version and a compressed air version up to 230 l/h are also available.
For constant dosing, with input for tank level control.
Pump head: PVDF, PP, PMMA or AISI 316L
The pump doses at a constant injection frequency, proportional to the flow rate percentage set with the analogue selector (0 – 100%).
Operation similar to constant dosing, with the selector adjustable between 0 and 10%: the maximum flow rate is reduced to as little as 1/10 of the rated value.
The pump code is made up of the model name and the performance: maximum pressure in bar as two digits followed by the flow rate in l/h (TCL 0515 = 5 bar, 15 l/h). It is followed by the pump head code and the power supply code, listed in the tables at the end of this section. Performance varies with the working back pressure and with the characteristics of the chemical.
Suitable for most chemicals: the standard configuration for the most common applications.
| Code | Max pressure (bar) | Max flow rate (l/h) | Delivery tube (mm) | Suction tube (mm) | cc per stroke |
|---|---|---|---|---|---|
| TCL 2005 | 20 | 5 | 4 x 6 | 4 x 6 | 0.7 |
| TCL 0515 | 5 | 15 | 6 x 8 | 6 x 8 | 2.1 |
| TCL 0420 | 4 | 20 | 6 x 8 | 6 x 8 | 2.8 |
| TCL 0330 | 3 | 30 | 8 x 10 | 8 x 12 | 4.2 |
| TCL 0150 | 1 | 50 | 8 x 10 | 8 x 12 | 7 |
| TCL 00100 | 0 | 100 | 12 x 18 (braided PVC) | 12 x 18 (braided PVC) | 14 |
Required with chemicals that release gas (e.g. peroxides), to prevent the pump from becoming air-locked.
| Code | Max pressure (bar) | Max flow rate (l/h) | Delivery tube (mm) | Suction tube (mm) | cc per stroke |
|---|---|---|---|---|---|
| TA CL 203.2 | 20 | 3.2 | 4 x 6 | 4 x 6 | 0.44 |
| TA CL 0510 | 5 | 10 | 6 x 8 | 6 x 8 | 1.39 |
| TA CL 0413 | 4 | 13 | 6 x 8 | 6 x 8 | 1.8 |
| TA CL 0320 | 3 | 20 | 8 x 10 | 8 x 12 | 2.78 |
| TA CL 0135 | 1 | 35 | 8 x 10 | 8 x 12 | 4.86 |
For dosing large quantities of chemical in industrial applications.
| Code | Max pressure (bar) | Max flow rate (l/h) | Delivery tube (mm) | Suction tube (mm) | cc per stroke |
|---|---|---|---|---|---|
| T AC CL 1050 | 10 | 50 | 8 x 10 | 8 x 12 | 7 |
| T AC CL 05150 | 5 | 150 | 13 x 16 | 12 x 18 | 20.8 |
| T AC CL 00230 | 0 | 230 | 13 x 16 | 12 x 18 | 32 |
| Specification | Value |
|---|---|
| Strokes | From 12 to 120 per minute |
| Maximum chemical viscosity | 100 cP; 8,000 cP with the $ pump head |
| Average power draw at maximum flow rate (manual and automatic air bleed) | 27 W at 230 VAC and 21 W at 115 VAC; on models 0515 and 0510, 15 W at 115 VAC and 14 W at 24 VAC and 24 VDC |
| Protection rating | IP65; IP54 in the compressed air version |
| Noise level | 62.0 dB(A); 78.3 dB(A) in the compressed air version |
| Weight | 5.7 kg; 9 kg in the compressed air version |
| Housing | PP |
| Mounting | Vertical, or horizontal with the dedicated bracket |
| Ambient temperature | 0 – 45 °C |
| Product temperature | 0 – 50 °C |
| Transport and storage temperature | −10 – 50 °C |
| Relative humidity | 85 % up to 40 °C, 70 % at 45 °C, non-condensing |
| Maximum altitude | 2,000 m a.s.l. |
| Installation category | II |
| Pollution degree | 2 |
| Compressed air (AC version) | 6 – 10 bar, free of lubricant and condensate |
| Head | Material | O-rings | Valves | Balls | Delivery tube | Suction tube | Max viscosity (cP) |
|---|---|---|---|---|---|---|---|
| K | PVDF | FKM | PVDF | Ceramic | PVDF | PVC | 100 |
| P | PVDF | EPDM | PVDF | Ceramic | PVDF | PVC | 100 |
| W | PVDF | NBR | PVDF | Ceramic | PVDF | PVC | 100 |
| V | PP | FKM | – | Ceramic | PE | PVC | 100 |
| D | PP | EPDM | – | Ceramic | PE | PVC | 100 |
| T | PVDF | FKM + PTFE | PVDF | Ceramic | PVDF | PVC | 100 |
| A | PMMA | FKM | PP | Ceramic | PVDF | PVC | 100 |
| Z | AISI 316L | FKM | AISI 316L | AISI 316L | – | – | 100 |
| $ | PMMA | FKM | PP | Stainless steel, Hastelloy spring | PE | PVC | 8,000 |
PTFE diaphragm for all pump heads. The tube size may vary with the pump head material; with low-viscosity liquids the $ pump head may reduce the flow rate.
| Code | Power supply |
|---|---|
| 00 | 230 VAC, Schuko plug |
| 0S | 230 VAC, Australian plug |
| 01 | 230 VAC, no plug |
| 03 | 115 VAC, US plug |
| 04 | 24 VAC, no plug |
| 05 | 12 VDC (some models only) |
| 07 | 24 VDC |
Suitable for most acids, for peroxides and for sodium hypochlorite (chlorine).
Suitable for sodium hydroxide (caustic soda).
Suitable for peracetic acid and sodium hydroxide.
Suitable for medium and high viscosity substances.
In addition to the standard configuration, versions dedicated to particular applications are available; the performance of each is given in the technical data. The pages by application compare the suitable pumps of all the series.
Self-venting pump head, required with chemicals that release gas (e.g. sodium hypochlorite and peroxides): it vents the gas and prevents the pump from locking.
PMMA pump head for high-viscosity liquids, from 8,000 to 50,000 cP.
For dosing large quantities of chemicals in industrial applications: up to 230 l/h.
The most frequent causes of malfunction and the corrective actions to check before contacting technical support.
Learn more: the pump does not prime and does not dose →| LED | Meaning | Action |
|---|---|---|
| 3 flashes per second | Mains voltage below the rated value. | Check the power supply. |
| 2 flashes per second | Mains voltage above the rated value. | Check the power supply. |
| 1 flash every 2 seconds | Pump OFF, powered. | No action required. |
| On, goes off at each stroke | Pump running. | No action required. |
| On, goes off every 2 seconds | Pump in divide mode (frequency reduced by a factor of 10). | No action required. |
| Steady red (two-colour LED) | Chemical below the minimum level: the pump stops. | Restore the chemical level in the tank. |
| Green, flashing every second (two-colour LED) | Supply voltage out of range. | Check that the mains voltage matches the rated value. |
Adjustment is linear between 30 and 100%: below 30% the actual flow rate may differ from the expected one and must therefore be checked.
Connect all the tubing, open the bleed valve and set the adjustment to 100%; start the pump and close the bleed valve as soon as the chemical comes out. With viscous liquids the operation can be assisted with a 20 cc syringe applied to the bleed port.
With the pump switched off, hold down both arrow keys and restore power: LOAD DEFAULT appears and the programming is reset to the factory values (password 0000).
If the problem persists, contact us. Before sending the pump for servicing, empty the pump head of chemical and dry it.
According to the operating mode and the set parameters, the pump automatically adapts the injection frequency to ensure the required dosing.
The pump is supplied with a low-level probe for the tank: when the chemical runs out, it shows the alarm on the display and activates the corresponding output.
A dedicated button allows the lines to be filled with the chemical to be dosed.
Vertical installation, or horizontal installation by means of a dedicated bracket.
Tell us about your application: our technical staff will recommend the most suitable model, configuration and accessories.
Call or write to us: a technician will reply with a tailored proposal of controllers, pumps, probes and accessories.