LDsCL for peracetic acid

The LDsCL controller for peracetic acid continuously measures the PAA concentration in industrial process and washing water and in wastewater. The SCL11 closed amperometric cell is available with a 0 – 200 mg/l or a 0 – 2,000 mg/l range, the widest among the cells that can be used with the LDsCL, and automatically compensates for temperature.

  • SCL11 closed amperometric cell
  • Ranges 0 – 200 and 0 – 2,000 mg/l
  • Process and washing water
  • Temperature compensation
LDsCL system for peracetic acid pre-assembled on a panel
LDsCLperacetic acid
Amperometric cells for hydrogen peroxide, ozone and peracetic acid
SCL11
0.1mg/lMaximum resolution
2,000mg/lMaximum range
1 – 9pHCell operating range
3minResponse time T90, approx.
Controller

The controller

It acquires the measurement from the cell and controls the dosing pump in proportion to the measured value.

Colour display

Multicolour backlit display that indicates the different operating states by changing colour. Programming via a single knob.

Four modes

Proportional, ON/OFF, PWM and PID dosing, with delayed dosing start.

Data storage

Permanent data storage and a system log viewable on the display; the internal log can be exported to a USB memory stick for processing with a spreadsheet.

Alarms

Chemical level, no flow, maximum dosing time exceeded, probe failure, out-of-range reading; audible or visual signalling via the alarm output.

Colour display

Colour-coded status indication

By changing colour, the controller’s backlit display indicates the different operating states, which can be recognised even from a distance.

Display Normal operation

Normal operation

Measurement and dosing according to the set parameters.

Display Stand-by

Stand-by

Controller in stand-by.

Display Warning

Warning

Warning signal, for example the chemical level.

Display Alarm

Alarm

Alarm signal, for example from the probe.

Settings from the display

LDsCL display: set point setting in proportional mode
Proportional mode: 180 pulses per minute at 0.100 mg/l, pump stopped at 0.500 mg/l
Versions

BASIC and PLUS versions

The instrument is available in two versions, which differ in the number of inputs and outputs: the PLUS version adds the meter input, PID control, a second level input, a second dosing pump output, the 0-4/20 mA current loop outputs and the outputs for probe self-cleaning and for the circulation pump.

BASICPLUS
Measuring channels1 + temperature1 + temperature
Level inputs12
Flow input11
Stand-by input11
Meter input–1
Outputs for pumps and loads (relays)1 (ON/OFF, PWM)2 (ON/OFF, PWM, PID)
Proportional outputs for dosing pumps12
Alarm output11
0-4/20 mA current loop outputs2 on request3
Probe self-cleaning output–1
Circulation pump output–1
Modbus RTU●Optional
Ethernet, Wi-Fi, 4G, USBOptionalOptional
Data sheet

Controller data sheet

Inputs, outputs, control modes and alarms of the controller.

Inputs

  • Measuring probe
  • Temperature
  • Flow sensor
  • Stand-by
  • Chemical level: 1 (BASIC), 2 (PLUS)
  • Pulse-output water meter or mA signal (PLUS)

Outputs

  • Proportional dosing pumps: 1 (BASIC), 2 (PLUS)
  • Relay outputs for pumps and loads: 1 (BASIC), 2 (PLUS)
  • Alarm output
  • 0-4/20 mA current loop outputs: 3 (PLUS), 2 on request (BASIC)
  • Probe self-cleaning and circulation pump (PLUS)

Control

  • Proportional
  • ON/OFF
  • PWM
  • PID (PLUS)
  • Delayed start

Alarms

  • Chemical level
  • No flow
  • Maximum dosing time
  • Probe failure
  • Out-of-range reading

Power supply

  • 230 VAC
  • 12 – 24 VDC
The model

LDsCL for peracetic acid

Amperometric cells for hydrogen peroxide, ozone and peracetic acid
0 – 200 · 0 – 2,000 mg/l

Peracetic acid

For measuring peracetic acid (PAA) in industrial process and washing water and in wastewater.

Compatible components
SCL11 SCL11Closed amperometric cell with selective membrane.
Cells

Closed and open amperometric cells

SCL closed or ECL open amperometric cells are connected to the LDsCL controller, resulting in the different versions.

Learn more: Redox, open amperometric cell and closed amperometric cell →
SCL closed amperometric cell

SCL closed amperometric cell

The electrodes are protected by a selective membrane that allows only the oxidant of interest to be measured, without interference from other substances. Automatic temperature compensation (and pH compensation for free chlorine), resolution down to 0.001 mg/l.

SCL cells →
SCL17 and SCL18 self-cleaning cells

Self-cleaning for hot water

Membrane-free, with 3 electrodes (one measuring and two reference), with ball self-cleaning: suitable up to 70 °C and less sensitive to fouling. For free chlorine (SCL18) and chlorine dioxide (SCL17).

SCL17 and SCL18 →
ECL open amperometric cell

ECL open amperometric cell

Direct measurement of free chlorine in mg/l in swimming pool water, including salt water.

ECL cells →
Operation

Measuring principle of the closed amperometric cell

The cell consists of an electronic section and a galvanic section.

Learn more: Redox, open amperometric cell and closed amperometric cell →
1

Selective membrane

The measuring electrodes are protected from direct contact with the water by a semi-permeable membrane: only the specific oxidant is measured, without interference from other substances that could alter the measurement.

2

Galvanic measurement

The electrodes of the galvanic section detect the electric current generated by the dissociation of the oxidant.

3

Compensation and signal

The cell electronics compensate the reading for temperature (and, where applicable, pH) and send the signal to the controller, which shows the concentration in mg/l on the display.

Technical data

Technical data of the cell and controller

Measuring range, resolution and characteristics of the cell for measuring peracetic acid. The controller is common to all parameters: inputs, outputs and connections are described in the controller sections.

Measuring range

ParameterRangeResolutionCellCompensation
Peracetic acid0 – 200 mg/l
0 – 2,000 mg/l
0.1 mg/l
1 mg/l
SCL11Temperature
Temperature0 – 100 °C0.1 °C––

Controller characteristics

CharacteristicValue
Average power consumption25 W
Relay outputs5 A at 230 VAC, fuse-protected
Delayed dosing startUp to 60 minutes
NetworkingUp to 31 controllers
Ambient temperature−10 – 50 °C
Relative humidity0 – 95 %, non-condensing
Protection ratingIP65
HousingABS
Weight1.45 kg
MountingWall-mounted, with four fixing points

Supplied with the SCL11 cell

  • Cell complete with membrane cap, protective cap and clamping ring
  • Connector cable
  • Electrolyte
  • Powder-free nitrile gloves
  • Manual
Complete systems

Complete systems with LDsCL

The controller is the core of the measuring and dosing system: for each application, the system page gives the composition, the installation diagram and the installation.

Peracetic acid

Measuring and dosing systemsPeracetic acid

Dosing of peracetic acid in the food industry and in washing processes.

The system →

For wastewater and for plants with special requirements the system is defined on the characteristics of the plant: contact us.

Measurement

Cell for measuring peracetic acid

For measuring peracetic acid (PAA) in industrial process and washing water and in wastewater.

Probe data sheets

Closed amperometric cells

SCL11/200SCL11/2000
Measuring range0 – 200 mg/l0 – 2,000 mg/l
Resolution0.11
Operating pH1 – 91 – 9
Operating pressure1 bar1 bar
Electrodes22
Selective membrane●●
Automatic compensationTemperatureTemperature
Operating temperature1 – 40 °C1 – 40 °C
Water flow30 l/h30 l/h
Response time (T90)approx. 3 minapprox. 3 min
Start-up timeapprox. 1 happrox. 1 h
Replacement electrolyteELESCL11ELESCL11
Replacement membraneMESCL11MESCL11
MaterialsPVC-U and 1.4571 stainless steelPVC-U and 1.4571 stainless steel
DimensionsØ 25 × 241 mmØ 25 × 241 mm
MaintenanceElectrolyte replacement every 3 – 6 monthsElectrolyte replacement every 3 – 6 months
Remote control

System remote control

The controllers support two-way remote access (read and write) through the web portal from a PC, tablet or smartphone: measurements can be viewed, set points, dosing and alarms changed, alarms received and logs downloaded. Alternatively, they can be integrated into your PLC via Modbus.

Ethernet

Connection to the web portal via network cable: measurements, set points, dosing and alarms accessible from a PC, tablet or smartphone.

Optional (one only)

Wi-Fi

Wireless connection to the web portal, with the same functions as the cable connection.

Optional (one only)

4G

Connection via the 4G network for installations without a local network, with alarm notification by SMS or e-mail.

Optional (one only)
NIMBUS web portal for remote control of the systemsWeb portalPC, tablet and smartphone

Modbus RTU

Integration into your PLC via serial port.

Standard (BASIC), optional (PLUS)

0-4/20 mA current loop output

Current signal proportional to the measured value, for remote monitoring or for controlling pumps and other instrumentation.

3 standard (PLUS), 2 on request (BASIC)

USB port

Download of the logged data to a USB memory stick, for archiving and analysis with a spreadsheet.

Optional

One communication type at a time: Ethernet, Wi-Fi, 4G or Modbus RTU (built into the BASIC versions, optional on the PLUS versions). 0-4/20 mA current loop outputs standard on the PLUS versions, optional on the BASIC versions; meter input on the PLUS versions only.

The NIMBUS portal

A single account brings together all registered installations, each with its own devices: the web portal, free of charge and with no subscription, can be accessed from a PC, Mac, tablet or smartphone and allows every parameter to be both viewed and changed, with an encrypted connection and protected access.

The NIMBUS portal on monitor, laptop, tablet and smartphone

Overview

On a single screen: probe readings, chemical levels, pump activation thresholds and active alarms, with the status of installations and devices (normal, warning, alarm, standby, not connected).

Installation map

Installations appear on an interactive map with their status and open with a click; for each one, the local weather conditions and temperature are also shown.

History and charts

Archive of measurements and alarms, available for consultation at any time with charts and numerical reports exportable in Excel format.

Alarms and notifications

Alarm thresholds for readings, dosing, faulty probe and out-of-range readings, with notification by e-mail or SMS depending on the communication system; a warning is also issued when an installation remains disconnected beyond the set time.

Set points and dosing

Remote modification of the set points, of the dosing pump activation thresholds and of the corresponding hourly flow rate.

Inputs and outputs

Status of relays, pulse outputs, digital inputs and current outputs, with the name assigned to each connection.

Maintenance calendar

Tasks are scheduled by installation or by device and assigned to technicians; a reminder is sent by e-mail two days before the due date. Each task is shown as scheduled, due, overdue or completed.

Team and permissions

The main account has full access and creates the technicians’ accounts, each enabled only for the assigned installations and devices; the last login and activity of each technician are visible.

Reports and activity log

Reports on devices, tasks and technicians, downloadable in PDF or CSV with the customer’s logo; the log keeps the history of operations and disconnections.

Customisation

Logo, main colour and light or dark theme; the tiles on the main screen can be rearranged by dragging them. Two installations can be displayed side by side for comparison.

Guided registration

Each device is added through a guided procedure: the model is recognised automatically and associated with the installation, together with the technician to be contacted.

PLC integration

As an alternative to the portal, the Modbus RTU port allows integration into the plant supervision system.

NIMBUS portal: Real-time readings, counters and timers
Real-time readings, counters and timers
NIMBUS portal: Free chlorine and temperature trends
Free chlorine and temperature trends
NIMBUS portal: Set point and operating mode of each channel
Set point and operating mode of each channel
NIMBUS portal: Status of relays, pulses, inputs and mA outputs
Status of relays, pulses, inputs and mA outputs

Technical advice

Tell us the product to be dosed, the volumes of water treated and the characteristics of the plant: we will propose the most suitable cell, pump and accessories.

Contact

Tell us about your plant

Call or write to us: a technician will reply with a tailored proposal of controllers, pumps, probes and accessories.

What do you need?
Please enter your name.
Please enter a valid email address.
Please enter your message.

Describe your plant: type, water volume or flow rate, parameters to be controlled.

You must accept the privacy notice to continue.