Skip to content
Measurement and logging

LDLOG SEFL

The LDLOG SEFL controller permanently totalises the volume of treated water, measured by up to three pulse-output water meters, and the quantity of chemical injected by the dosing pumps, detected by as many SEFL flow sensors. Daily, monthly and yearly totals can be viewed on the display and are logged at programmable intervals, with password-protected access.

  • 3 pulse-output water meters
  • 3 SEFL flow sensors
  • Evaporation calculated by the third meter
  • Logging every 15 minutes to 1 day
LDLOG SEFL controller with dosed products display
LDLOG SEFLTreated water and dosed products
3Water meter inputs
3Flow sensor inputs
15minMinimum logging interval
IP65Protection rating
How it works

Two quantities, a single log

LDLOG controllers acquire the signals of the devices installed on the plant and permanently store their totalised values, making it possible to document operation and to verify that the treatments are carried out correctly.

Turbine and Woltmann pulse-output water meters

Treated water

The pulse-output water meter installed on the pipe of the water to be treated sends one pulse for each preset volume: the controller totalises the litres that have passed through.

Water meters →
SEFL flow sensor

Dosed product

The flow sensor, installed on the delivery of the dosing pump, detects each injection; knowing the volume of a single injection, which can be determined with a simple test, the controller calculates the quantity of product dosed.

Flow sensor →
Display

Data viewable on the display

The log can be viewed directly on the controller, with the daily, monthly and yearly totals of each input.

LDLOG SEFL display: litres dosed of inhibitor and of two biocides

Dosed products (SEFL)

Quantity dosed of each product, in litres.

LDLOG SEFL display: cubic metres of make-up water, bleed-off and evaporation

Water volumes (SEFL)

Volumes measured by the water meters, for example make-up water, bleed-off and evaporation of a cooling tower.

The model

LDLOG SEFL

LDLOG SEFL controller
Treated water and dosed products

LDLOG SEFL

Collects and permanently stores the data of up to 3 pulse-output water meters for the treated water and of 3 flow sensors installed on the dosing pumps, monitoring the volume of water treated and the consumption of chemical products.

Technical data

Data sheet

For each pump the volume of a single injection is set, and for each water meter the ratio between pulses and litres; the third meter can add up the volumes or calculate the difference between make-up and bleed-off, giving the water evaporated by a cooling tower.

Technical specifications

FeatureLDLOG SEFL
Inputs3 SEFL flow sensors, 3 pulse-output water meters
Logged quantitiesVolume of treated water, quantity of dosed product
Volume per pump injection0.01 – 99.00 ml per pulse
Water meter scale0.1 – 999.9 pulses per litre or litres per pulse
Third water meterSum or difference between two meters (evaporation)
TotalisationDaily, monthly, yearly
Logging interval15 minutes, 1 hour, 6 hours, 12 hours or 1 day
Log file formatCSV and encrypted EMC
CommunicationRS485, Modbus, USB, Ethernet, 4G
Data protectionPassword-protected access
DisplayRGB LCD display
Power supply85 – 264 VAC, 50/60 Hz
Average power consumption25 W
Protection ratingIP65
Ambient temperature−10 – 50 °C
Relative humidity0 – 95 %, non-condensing
Complete systems

Complete systems with LDLOG

The LDLOG is added to the dosing system to record its operating data: the system page gives the composition, the installation diagram and the installation.

Volumetric dosing stations

Production and dosingVolumetric dosing stations

The pulse-output water meter on the water line controls the dosing pump; the LDLOG SEFL totals its pulses and, with the flow sensor on the delivery, records the product actually dosed.

The system →
Cooling towers

Cooling towersCooling towers

The LDLOG SEFL records the make-up and bleed-off volumes, obtains the evaporated water by difference and totals the inhibitor and biocides dosed.

The system →
Remote control

Data transmission and protection

The controllers support two-way remote access via Ethernet or the 4G network, with SMS or e-mail notifications when alarms are triggered, or can be integrated into the PLC via Modbus; the USB port also allows the recorded data to be downloaded to external memory for analysis with a spreadsheet. Access is password-protected, ensuring that the data cannot be altered from the controller to the point of delivery (web server or PLC).

USB port

Download of the logged data to a USB memory stick, for archiving and analysis with a spreadsheet.

Optional

Ethernet

Connection to the web portal via network cable: measurements, set points, dosing and alarms accessible from a PC, tablet or smartphone.

Optional

4G

Connection via the 4G network for installations without a local network, with alarm notification by SMS or e-mail.

Optional

Modbus RTU

Integration into your PLC via serial port.

Optional

Technical advice

Tell us the quantities to be logged, the number of water meters, pumps and tanks and how the data are to be consulted: we will propose the most suitable controller and accessories.

Contact

Tell us about your plant

Call or write to us: a technician will reply with a tailored proposal of controllers, pumps, probes and accessories.

What do you need?
Please enter your name.
Please enter a valid email address.
Please enter your message.

Describe your plant: type, water volume or flow rate, parameters to be controlled.

You must accept the privacy notice to continue.