Peracetic acid channel
The pump starts when the concentration falls below the SET POINT ON and slows down as it approaches the SET POINT OFF, where it stops: the injection frequency decreases near the desired value, avoiding overdosing.
The system measures and controls the Redox potential (ORP) and the concentration of a disinfectant read with a closed amperometric cell, typically peracetic acid, in addition to temperature. Redox electrode, cell, temperature probe and flow sensor are combined in a single flow-through probe holder, in by-pass on the plant, and dosing matches the actual conditions of the water.
The amperometric cell directly measures the disinfectant concentration in mg/l; the Redox electrode detects the overall oxidising power. The two measurements, taken on the same sample, allow dosing that matches the actual conditions of the water.
The pump starts when the concentration falls below the SET POINT ON and slows down as it approaches the SET POINT OFF, where it stops: the injection frequency decreases near the desired value, avoiding overdosing.
The Redox potential, with a range of ± 1,000 mV and 1 mV resolution, has two proportional pulse outputs and one relay output, with its own set points.
The flow sensor in the probe holder stops dosing when the circulation system is stopped.
The system is supplied pre-assembled on a panel, in a cabinet or on a skid, tested before delivery.
It monitors Redox, peracetic acid and temperature, the tank levels and the presence of flow, and drives up to three proportional dosing pumps.
The controller →
Closed amperometric cell with selective membrane and automatic temperature compensation, with a range up to 2,000 mg/l. The galvanic part, the only one subject to wear, can be regenerated without replacing the electronics.
SCL cells →
Combined electrode for Redox measurement, with a range from −1,000 to +1,000 mV and 1 mV resolution.
Redox electrodes →
In PMMA, with 6 × 8 mm fittings, it houses cell, electrode, temperature probe and flow sensor; it has a flow regulator, anti-vacuum valve and sampling tap.
Probe holders →
5" filter with washable 60 micron PET cartridges or 100 micron string-wound cartridges, maximum operating pressure 5 bar.
Probe holders →
With flow rate and back pressure configured when ordering, supplied with a pre-set injection valve and a level probe that stops the pump when the product runs out.
Dosing pumps →In addition to three proportional outputs for the pumps, the controller has two powered digital outputs, driven by set point, to control pumps or solenoid valves.
Maximum or minimum measurement reached, set point not reached within the set time, electrode reading unchanged for a long time, products depleted and lack of flow in the cell.
When an alarm is triggered the dedicated output can give an audible and visual warning.
Washing and process water disinfected with peracetic acid, whose concentration must remain within the established values in every processing stage.
Learn more: food industry →
Industrial process water in which both the disinfectant concentration and the Redox potential are monitored.
Learn more: industrial water →
Disinfection of municipal and industrial wastewater with monitoring of the residual disinfectant.
Learn more: wastewater →The amperometric channel accepts the other cells of the series: with the closed SCL cell free chlorine, total chlorine, chlorine dioxide, bromine, hydrogen peroxide, ozone or chlorites can also be measured; with the open ECL cell, free chlorine in swimming pool water. Range and resolution depend on the selected cell.

Measuring ranges, resolution, inputs, outputs, display and connections are given in the controller data sheet.
The controllers support two-way remote access (read and write) through the web portal from a PC, tablet or smartphone: measurements can be viewed, set points, dosing and alarms changed, alarms received and logs downloaded. Alternatively, they can be integrated into your PLC via Modbus.
Connection to the web portal via network cable: measurements, set points, dosing and alarms accessible from a PC, tablet or smartphone.
Wireless connection to the web portal, with the same functions as the cable connection.
Connection via the 4G network for installations without a local network, with alarm notification by SMS or e-mail.
Web portalPC, tablet and smartphone
Integration into your PLC via serial port.
Current signal proportional to the measured value, for remote monitoring or for controlling pumps and other instrumentation.
Download of the logged data to a USB memory stick, for archiving and analysis with a spreadsheet.
One communication type at a time: Ethernet, Wi-Fi, 4G or Modbus RTU (built into the BASIC versions, optional on the PLUS versions). 0-4/20 mA current loop outputs optional; meter input on the PLUS versions only.
A single account brings together all registered installations, each with its own devices: the web portal, free of charge and with no subscription, can be accessed from a PC, Mac, tablet or smartphone and allows every parameter to be both viewed and changed, with an encrypted connection and protected access.
On a single screen: probe readings, chemical levels, pump activation thresholds and active alarms, with the status of installations and devices (normal, warning, alarm, standby, not connected).
Installations appear on an interactive map with their status and open with a click; for each one, the local weather conditions and temperature are also shown.
Archive of measurements and alarms, available for consultation at any time with charts and numerical reports exportable in Excel format.
Alarm thresholds for readings, dosing, faulty probe and out-of-range readings, with notification by e-mail or SMS depending on the communication system; a warning is also issued when an installation remains disconnected beyond the set time.
Remote modification of the set points, of the dosing pump activation thresholds and of the corresponding hourly flow rate.
Status of relays, pulse outputs, digital inputs and current outputs, with the name assigned to each connection.
Tasks are scheduled by installation or by device and assigned to technicians; a reminder is sent by e-mail two days before the due date. Each task is shown as scheduled, due, overdue or completed.
The main account has full access and creates the technicians’ accounts, each enabled only for the assigned installations and devices; the last login and activity of each technician are visible.
Reports on devices, tasks and technicians, downloadable in PDF or CSV with the customer’s logo; the log keeps the history of operations and disconnections.
Logo, main colour and light or dark theme; the tiles on the main screen can be rearranged by dragging them. Two installations can be displayed side by side for comparison.
Each device is added through a guided procedure: the model is recognised automatically and associated with the installation, together with the technician to be contacted.
As an alternative to the portal, the Modbus RTU port allows integration into the plant supervision system.
Tell us the process, the water flow rate and the required disinfectant concentration: we will propose the most suitable cell, pumps and system version.
Call or write to us: a technician will reply with a tailored proposal of controllers, pumps, probes and accessories.