| ALARM LEVEL | Chemical tank empty. | Refill the tank. |
| OVER FLOW | The required working frequency exceeds the rated frequency. | Check the settings and the pump flow rate, then switch the pump off and on again. |
| ALARM STROKE | The set flow rate exceeds the rated flow rate. | Check the settings and the flow rate, then switch the pump off and on again. |
| ALARM POWER | The power supply is outside the permitted values. | Check that the voltage matches the rating plate data, then switch the pump off and on again. |
| ALARM BATCH | Batch dosing was interrupted because the external contact changed state. | Check that the connected contact matches the pump setting, then switch the pump off and on again. |
| INPUT OPEN | In mA or Volt mode the input signal is missing. | Check the external signal and its connection. |
| ERROR DATA | The values entered are not consistent. | Check the values; if they are correct and the error persists, the pump is undersized for the required dosing. |
| ERROR MEM | Error in the settings memory. | Restore the factory values with the reset procedure. |
| WRONG ENTRY | Invalid setting, for example the same value for the minimum and the maximum of the signal. | Set distinct, correct values. |
| Incorrect password | The password entered does not match the stored one. | Contact us to unlock it. |