Skip to content
Peristaltic dosing pump

Velon PO

Peristaltic dosing pump with an integrated instrument for measuring and controlling pH or Redox (ORP). It doses in proportion to the deviation of the reading from the set point or, in automatic mode, according to the set value and the volume of the pool or tank. It has a backlit display, stand-by input, level control and a Wi-Fi connection to the cloud portal.

  • Integrated pH and Redox meter
  • Wi-Fi and Bluetooth as standard
  • Up to 12 l/h
  • Stand-by input
Velon PO peristaltic dosing pump
12l/hMaximum flow rate
2barMaximum pressure
1–100RPMRotor speed
IP65Protection rating
The model

Velon PO

Velon PO peristaltic dosing pump
pH meter and Redox meter

Velon PO

With integrated pH meter and Redox meter for automatic control of pH or Redox (ORP).

  • Proportional to pH
  • Proportional to Redox
  • Automatic pH dosing
  • Automatic Redox dosing
Compatible components
EpHS EpHSpH electrode
ERhS ERhSRedox (ORP) electrode
Operation

Dosing modes

Proportional to pH

The required pH value (SET POINT) is set: the pump measures the pH by means of a pH electrode and progressively reduces the injection frequency as the measured value approaches the set point, stopping when the SET POINT is reached.

Proportional to Redox

The required Redox potential (ORP) (SET POINT) is set: the pump measures it by means of a Redox electrode and progressively reduces the injection frequency as the measured value approaches the set point, stopping when the SET POINT is reached.

Automatic pH dosing

Once the pool volume has been set, the pump automatically adjusts dosing according to the required pH (SET POINT), measured by means of a pH electrode: the injection frequency is progressively reduced as the measured value approaches the set point, until the pump stops when the SET POINT is reached.

Automatic Redox dosing

Once the pool volume has been set, the pump automatically adjusts dosing according to the required Redox potential (ORP) (SET POINT), measured by means of a Redox electrode: the injection frequency is progressively reduced as the measured value approaches the set point, until the pump stops when the SET POINT is reached.

Technology

Stepper motor peristaltic technology

Peristaltic pumps deliver the product continuously; the electronically controlled stepper motor optimises dosing, which is continuous and free of pulsations. The flow rate is adjusted by frequency, by varying the number of revolutions per minute of the motor.

Turndown ratio of the stepper motor

Stepper motor

The stepper motor and the control software deliver the product optimally with completely silent operation, a feature appreciated when dosing aromatic essences in saunas and Turkish baths, or pH adjuster and disinfectant in swimming pools and hot tubs.

TPV peristaltic tube and rotor of the Velon pumpTPV peristaltic tube and rotor of the Velon pump

TPV peristaltic tube

The tube is made of TPV, an elastomer compatible with most chemicals, which retains its elastic properties even after millions of compression cycles by the rollers. The Velon is also suitable for dosing products that release gas, such as hydrogen peroxide or peracetic acid.

Colour display

Colour-coded status indication

The display backlight colour changes according to the operating status, so that an alarm can be recognised even from a distance.

Display Green

Green

Normal operation according to the set parameters, no active alarms.

Display Yellow

Yellow

Non-blocking alarm, for example waiting for an external signal.

Display Red

Red

Blocking alarm, for example the chemical in the tank running out.

Display White

White

Pump stopped by an external control signal (stand-by).

Remote control

Remote control and connectivity

The pump supports two-way remote control: from the cloud portal, via Wi-Fi, settings can be changed, the reading and operation can be checked and alarms can be received; alternatively, it can be integrated into a PLC via Modbus RTU and programmed via Bluetooth from a smartphone.

Remote control of the Velon pump via the cloud portal

Integrated Wi-Fi

Allows connection to the NIMBUS cloud portal to change settings, check operation and receive alarms, such as the chemical running out.

Standard

Integrated Modbus RTU

Integration into your PLC: all pump parameters can be managed from your control interface.

Standard

Bluetooth

Pump programming directly from a smartphone.

Standard

The NIMBUS portal

A single account brings together all registered installations, each with its own devices: the web portal, free of charge and with no subscription, can be accessed from a PC, Mac, tablet or smartphone and allows every parameter to be both viewed and changed, with an encrypted connection and protected access.

The NIMBUS portal on monitor, laptop, tablet and smartphone

Overview

On a single screen: probe readings, chemical levels, pump activation thresholds and active alarms, with the status of installations and devices (normal, warning, alarm, standby, not connected).

Installation map

Installations appear on an interactive map with their status and open with a click; for each one, the local weather conditions and temperature are also shown.

History and charts

Archive of measurements and alarms, available for consultation at any time with charts and numerical reports exportable in Excel format.

Alarms and notifications

Alarm thresholds for readings, dosing, faulty probe and out-of-range readings, with notification by e-mail or SMS depending on the communication system; a warning is also issued when an installation remains disconnected beyond the set time.

Set points and dosing

Remote modification of the set points, of the dosing pump activation thresholds and of the corresponding hourly flow rate.

Inputs and outputs

Status of relays, pulse outputs, digital inputs and current outputs, with the name assigned to each connection.

Maintenance calendar

Tasks are scheduled by installation or by device and assigned to technicians; a reminder is sent by e-mail two days before the due date. Each task is shown as scheduled, due, overdue or completed.

Team and permissions

The main account has full access and creates the technicians’ accounts, each enabled only for the assigned installations and devices; the last login and activity of each technician are visible.

Reports and activity log

Reports on devices, tasks and technicians, downloadable in PDF or CSV with the customer’s logo; the log keeps the history of operations and disconnections.

Customisation

Logo, main colour and light or dark theme; the tiles on the main screen can be rearranged by dragging them. Two installations can be displayed side by side for comparison.

Guided registration

Each device is added through a guided procedure: the model is recognised automatically and associated with the installation, together with the technician to be contacted.

PLC integration

As an alternative to the portal, the Modbus RTU port allows integration into the plant supervision system.

NIMBUS portal: Real-time readings, counters and timers
Real-time readings, counters and timers
NIMBUS portal: Free chlorine and temperature trends
Free chlorine and temperature trends
NIMBUS portal: Set point and operating mode of each channel
Set point and operating mode of each channel
NIMBUS portal: Status of relays, pulses, inputs and mA outputs
Status of relays, pulses, inputs and mA outputs
Technical data

Performance and configurations

Performance depends on the diameter of the peristaltic tube and on the rotation speed of the motor, adjustable from 1 to 100 revolutions per minute, as well as on the characteristics of the chemical.

Peristaltic tubes

Suitable for dosing most chemicals.

Tube (mm)Max pressure (bar)Max flow rate (l/h)ml/revRPMFlow rate range (l/h)
1.6 × 1.621.80.31 – 1000.018 – 1.8
1.6 × 4.821221 – 1000.12 – 12

Technical specifications

SpecificationValue
User interfaceBacklit LCD display and encoder
InputsModbus RTU (RS485), stand-by, level, probe
OutputsAlarm (optional)
ConnectivityWi-Fi and Bluetooth (BLE), OTA firmware update
Power supply100 – 240 VAC, 12 VDC or 24 VDC
Maximum pressure2 bar
Rotor speed1 – 100 rpm
Maximum chemical viscosity100 cP
Ambient temperature10 – 45 °C
Chemical temperature0 – 50 °C
Transport and storage temperature−10 – 50 °C
Relative humidity85% up to 40 °C; 70% at 50 °C
Protection ratingIP65
Installation categoryII
Pollution degree2

Construction materials

ComponentMaterial
Pump bodyPC/ABS
CoverPC
Dust bushingPEEK/PPS
Tube retainer, tube and vent hose connectorsPVDF
RollersPOM (Delrin)
Long-life peristaltic tubeTPV

Supplied with

  • Injection valve
  • Level probe with foot filter
  • Stand-by cable
  • Modbus cable
  • Tubes
  • Wall plugs
  • Fuse
  • Operating manual
Technical support

Troubleshooting and error messages

The most frequent causes of malfunction and the corrective actions to check before contacting technical support.

Learn more: the pump does not prime and does not dose →

If the pump…

Irregular dosing, leaks or air intake
  • Peristaltic tube worn, hardened or deformedReplace the tube (see the procedure below).
  • Non-compliant tube or tube not fitted correctlyFit the tube specified for the model and check that it is properly secured.
No dosing at start-up
  • Pump not primedStop the motor, prime the pump and restart it.
  • Pressure above the rated valueStop the pump immediately and check the downstream system.

Tube replacement

Switch off and disconnect the pump, close the valves and drain the liquid. Open the cover, remove the rotor cover disc and take out the slide with the worn tube; insert the new slide and bring the tube into position by turning the roller holder. Check by hand that it rotates freely, reassemble and carry out a dry test. If the roller holder is removed, the letter “A” must face the operator.

Flow rate check

The TEST function runs the pump for the set time (1 – 60 minutes): measuring the chemical drawn in makes it possible to determine the actual flow rate under the installation conditions.

If the problem persists, contact us. Before sending the pump for servicing, empty the pump head of chemical and dry it.

Summary

Main features

Electronic flow rate adjustment

According to the operating mode and the set parameters, the pump automatically adapts the injection frequency to ensure the required dosing.

Digital display

The integrated LCD display allows the pump to be programmed and its operating status to be monitored at all times.

Level control

The pump is supplied with a low-level probe for the tank: when the chemical runs out, it shows the alarm on the display and activates the corresponding output.

Stand-by

Pump start and stop can be controlled remotely by means of a run/stop contact from a PLC or another source.

Alarm output (optional)

On request, in the event of a fault a volt-free contact is activated, configurable as normally open (N.O.) or normally closed (N.C.), to drive a visual or audible signalling device, send an SMS or report the event to a PLC.

Priming button

A dedicated button allows the lines to be filled with the chemical to be dosed.

Versatile mounting

Vertical installation, or horizontal installation by means of a dedicated bracket.

Technical advice

Tell us about your application: our technical staff will recommend the most suitable model, configuration and accessories.

Contact

Tell us about your plant

Call or write to us: a technician will reply with a tailored proposal of controllers, pumps, probes and accessories.

What do you need?
Please enter your name.
Please enter a valid email address.
Please enter your message.

Describe your plant: type, water volume or flow rate, parameters to be controlled.

You must accept the privacy notice to continue.