Velon PO
With integrated pH meter and Redox meter for automatic control of pH or Redox (ORP).
- Proportional to pH
- Proportional to Redox
- Automatic pH dosing
- Automatic Redox dosing
Peristaltic dosing pump with an integrated instrument for measuring and controlling pH or Redox (ORP). It doses in proportion to the deviation of the reading from the set point or, in automatic mode, according to the set value and the volume of the pool or tank. It has a backlit display, stand-by input, level control and a Wi-Fi connection to the cloud portal.
The required pH value (SET POINT) is set: the pump measures the pH by means of a pH electrode and progressively reduces the injection frequency as the measured value approaches the set point, stopping when the SET POINT is reached.
The required Redox potential (ORP) (SET POINT) is set: the pump measures it by means of a Redox electrode and progressively reduces the injection frequency as the measured value approaches the set point, stopping when the SET POINT is reached.
Once the pool volume has been set, the pump automatically adjusts dosing according to the required pH (SET POINT), measured by means of a pH electrode: the injection frequency is progressively reduced as the measured value approaches the set point, until the pump stops when the SET POINT is reached.
Once the pool volume has been set, the pump automatically adjusts dosing according to the required Redox potential (ORP) (SET POINT), measured by means of a Redox electrode: the injection frequency is progressively reduced as the measured value approaches the set point, until the pump stops when the SET POINT is reached.
Peristaltic pumps deliver the product continuously; the electronically controlled stepper motor optimises dosing, which is continuous and free of pulsations. The flow rate is adjusted by frequency, by varying the number of revolutions per minute of the motor.
The stepper motor and the control software deliver the product optimally with completely silent operation, a feature appreciated when dosing aromatic essences in saunas and Turkish baths, or pH adjuster and disinfectant in swimming pools and hot tubs.

The tube is made of TPV, an elastomer compatible with most chemicals, which retains its elastic properties even after millions of compression cycles by the rollers. The Velon is also suitable for dosing products that release gas, such as hydrogen peroxide or peracetic acid.
The display backlight colour changes according to the operating status, so that an alarm can be recognised even from a distance.
Normal operation according to the set parameters, no active alarms.
Non-blocking alarm, for example waiting for an external signal.
Blocking alarm, for example the chemical in the tank running out.
Pump stopped by an external control signal (stand-by).
The pump supports two-way remote control: from the cloud portal, via Wi-Fi, settings can be changed, the reading and operation can be checked and alarms can be received; alternatively, it can be integrated into a PLC via Modbus RTU and programmed via Bluetooth from a smartphone.

Allows connection to the NIMBUS cloud portal to change settings, check operation and receive alarms, such as the chemical running out.
Integration into your PLC: all pump parameters can be managed from your control interface.
Pump programming directly from a smartphone.
A single account brings together all registered installations, each with its own devices: the web portal, free of charge and with no subscription, can be accessed from a PC, Mac, tablet or smartphone and allows every parameter to be both viewed and changed, with an encrypted connection and protected access.
On a single screen: probe readings, chemical levels, pump activation thresholds and active alarms, with the status of installations and devices (normal, warning, alarm, standby, not connected).
Installations appear on an interactive map with their status and open with a click; for each one, the local weather conditions and temperature are also shown.
Archive of measurements and alarms, available for consultation at any time with charts and numerical reports exportable in Excel format.
Alarm thresholds for readings, dosing, faulty probe and out-of-range readings, with notification by e-mail or SMS depending on the communication system; a warning is also issued when an installation remains disconnected beyond the set time.
Remote modification of the set points, of the dosing pump activation thresholds and of the corresponding hourly flow rate.
Status of relays, pulse outputs, digital inputs and current outputs, with the name assigned to each connection.
Tasks are scheduled by installation or by device and assigned to technicians; a reminder is sent by e-mail two days before the due date. Each task is shown as scheduled, due, overdue or completed.
The main account has full access and creates the technicians’ accounts, each enabled only for the assigned installations and devices; the last login and activity of each technician are visible.
Reports on devices, tasks and technicians, downloadable in PDF or CSV with the customer’s logo; the log keeps the history of operations and disconnections.
Logo, main colour and light or dark theme; the tiles on the main screen can be rearranged by dragging them. Two installations can be displayed side by side for comparison.
Each device is added through a guided procedure: the model is recognised automatically and associated with the installation, together with the technician to be contacted.
As an alternative to the portal, the Modbus RTU port allows integration into the plant supervision system.
Performance depends on the diameter of the peristaltic tube and on the rotation speed of the motor, adjustable from 1 to 100 revolutions per minute, as well as on the characteristics of the chemical.
Suitable for dosing most chemicals.
| Tube (mm) | Max pressure (bar) | Max flow rate (l/h) | ml/rev | RPM | Flow rate range (l/h) |
|---|---|---|---|---|---|
| 1.6 × 1.6 | 2 | 1.8 | 0.3 | 1 – 100 | 0.018 – 1.8 |
| 1.6 × 4.8 | 2 | 12 | 2 | 1 – 100 | 0.12 – 12 |
| Specification | Value |
|---|---|
| User interface | Backlit LCD display and encoder |
| Inputs | Modbus RTU (RS485), stand-by, level, probe |
| Outputs | Alarm (optional) |
| Connectivity | Wi-Fi and Bluetooth (BLE), OTA firmware update |
| Power supply | 100 – 240 VAC, 12 VDC or 24 VDC |
| Maximum pressure | 2 bar |
| Rotor speed | 1 – 100 rpm |
| Maximum chemical viscosity | 100 cP |
| Ambient temperature | 10 – 45 °C |
| Chemical temperature | 0 – 50 °C |
| Transport and storage temperature | −10 – 50 °C |
| Relative humidity | 85% up to 40 °C; 70% at 50 °C |
| Protection rating | IP65 |
| Installation category | II |
| Pollution degree | 2 |
| Component | Material |
|---|---|
| Pump body | PC/ABS |
| Cover | PC |
| Dust bushing | PEEK/PPS |
| Tube retainer, tube and vent hose connectors | PVDF |
| Rollers | POM (Delrin) |
| Long-life peristaltic tube | TPV |
The most frequent causes of malfunction and the corrective actions to check before contacting technical support.
Learn more: the pump does not prime and does not dose →Switch off and disconnect the pump, close the valves and drain the liquid. Open the cover, remove the rotor cover disc and take out the slide with the worn tube; insert the new slide and bring the tube into position by turning the roller holder. Check by hand that it rotates freely, reassemble and carry out a dry test. If the roller holder is removed, the letter “A” must face the operator.
The TEST function runs the pump for the set time (1 – 60 minutes): measuring the chemical drawn in makes it possible to determine the actual flow rate under the installation conditions.
If the problem persists, contact us. Before sending the pump for servicing, empty the pump head of chemical and dry it.
According to the operating mode and the set parameters, the pump automatically adapts the injection frequency to ensure the required dosing.
The integrated LCD display allows the pump to be programmed and its operating status to be monitored at all times.
The pump is supplied with a low-level probe for the tank: when the chemical runs out, it shows the alarm on the display and activates the corresponding output.
Pump start and stop can be controlled remotely by means of a run/stop contact from a PLC or another source.
On request, in the event of a fault a volt-free contact is activated, configurable as normally open (N.O.) or normally closed (N.C.), to drive a visual or audible signalling device, send an SMS or report the event to a PLC.
A dedicated button allows the lines to be filled with the chemical to be dosed.
Vertical installation, or horizontal installation by means of a dedicated bracket.
Tell us about your application: our technical staff will recommend the most suitable model, configuration and accessories.
Call or write to us: a technician will reply with a tailored proposal of controllers, pumps, probes and accessories.