Measuring and dosing systems

Turbidity

The system continuously measures the turbidity of the water in NTU and, when it exceeds the set value, controls the motorised three-way valves that divert the turbid water to the drain, preventing it from reaching the storage tank and the points of use.

  • Turbidity in NTU
  • ETORB2 self-cleaning nephelometric probe
  • Diversion to drain with motorised valves
LDsETORB2 system on a panel with bypass probe holder and motorised drain valve
Systemon a panel
ETORB2 turbidity probe
ETORB2 probe
How it works

Control principle

Bypass installation: the probe, in the flow-through probe holder on the supply pipe, analyses the incoming water. If the turbidity exceeds the set point, the motorised three-way valve on the supply diverts the water to the drain; a second three-way valve, on the sampling return, discharges the dirty sampled water instead of sending it back to the storage tank. The probe holder has a motorised drain valve for cleaning and, on its head, the connection for the probe wash water.

Diagram of the LDsETORB2 system with the turbidimeter in a bypass line on the supply pipe: motorised three-way valve on the supply discharging the turbid water, second three-way valve on the sampling return discharging the dirty sampled water, drain valve for cleaning and wash water on the head of the probe holder, controller and booster pump
1

Continuous measurement

The probe continuously detects the turbidity of the water in the tank or in the pipe.

2

Diversion to drain

When the set point is exceeded, the controller switches the motorised three-way valve on the inlet line, which sends the turbid water to the drain instead of to the tank.

3

Return to set point

The valve stays in the drain position until the turbidity returns to the set value; the probe keeps analysing the incoming water.

Immersion

Immersion installation

Immersion installation is also possible: the probe is immersed directly in the storage tank and, when the set point is exceeded, the motorised three-way valve on the supply diverts the turbid water to the drain.

Diagram of the LDsETORB2 system with the turbidimeter immersed in the storage tank and the motorised three-way valve on the supply, which diverts the turbid water to the drain
Components

Basic components

The controller and the probe are completed by the motorised three-way valves of the plant, on the supply to the storage tank and on the sampling return, driven by the outputs of the controller.

LDsETORB2 controller

LDsETORB2 controller

It acquires the measurement from the probe and, through its outputs, controls the motorised valves according to the set point.

LDsETORB2 →
ETORB2 turbidity probe

ETORB2 turbidity probe

Nephelometric measurement with 90° scattered light, with integrated temperature sensor and water-jet cleaning of the optical window.

The probe →
Flow-through probe holder for the turbidity probe with motorised drain valve

Flow-through probe holder

It holds the probe in the flow of sample water; it is fitted with the motorised drain valve for cleaning and, on its head, the wash water connection.

Probe holders →
Installation

In a bypass line or immersion

LDsETORB2 system with bypass probe holder and drain valve

In a bypass line

In the flow-through probe holder, with motorised drain valve.

Probe holders →
Installation diagram of the ETORB2 probe in a bypass line: water inlet and outlet, probe holder, motorised valve, drain and wash water pipe

Installation diagram

Water inlet and outlet, motorised drain valve and probe wash water (maximum 1 bar).

Applications

Applications

Swimming pools

Swimming pools

Swimming pool water.

The controller

The LDsETORB2 controller

LDsETORB2 controller

LDsETORB2

Measuring ranges, resolution, characteristics of the ETORB2 probe, inputs, outputs and connections are given in the controller data sheet.

Remote control

System remote control

The controllers support two-way remote access (read and write) through the web portal from a PC, tablet or smartphone: measurements can be viewed, set points, dosing and alarms changed, alarms received and logs downloaded. Alternatively, they can be integrated into your PLC via Modbus.

Ethernet

Connection to the web portal via network cable: measurements, set points, dosing and alarms accessible from a PC, tablet or smartphone.

Optional (one only)

Wi-Fi

Wireless connection to the web portal, with the same functions as the cable connection.

Optional (one only)

4G

Connection via the 4G network for installations without a local network, with alarm notification by SMS or e-mail.

Optional (one only)
NIMBUS web portal for remote control of the systemsWeb portalPC, tablet and smartphone

Modbus RTU

Integration into your PLC via serial port.

Standard (BASIC), optional (PLUS)

0-4/20 mA current loop output

Current signal proportional to the measured value, for remote monitoring or for controlling pumps and other instrumentation.

3 standard (PLUS), 2 on request (BASIC)

USB port

Download of the logged data to a USB memory stick, for archiving and analysis with a spreadsheet.

Optional

One communication type at a time: Ethernet, Wi-Fi, 4G or Modbus RTU (built into the BASIC versions, optional on the PLUS versions). 0-4/20 mA current loop outputs standard on the PLUS versions, optional on the BASIC versions; meter input on the PLUS versions only.

The NIMBUS portal

A single account brings together all registered installations, each with its own devices: the web portal, free of charge and with no subscription, can be accessed from a PC, Mac, tablet or smartphone and allows every parameter to be both viewed and changed, with an encrypted connection and protected access.

The NIMBUS portal on monitor, laptop, tablet and smartphone

Overview

On a single screen: probe readings, chemical levels, pump activation thresholds and active alarms, with the status of installations and devices (normal, warning, alarm, standby, not connected).

Installation map

Installations appear on an interactive map with their status and open with a click; for each one, the local weather conditions and temperature are also shown.

History and charts

Archive of measurements and alarms, available for consultation at any time with charts and numerical reports exportable in Excel format.

Alarms and notifications

Alarm thresholds for readings, dosing, faulty probe and out-of-range readings, with notification by e-mail or SMS depending on the communication system; a warning is also issued when an installation remains disconnected beyond the set time.

Set points and dosing

Remote modification of the set points, of the dosing pump activation thresholds and of the corresponding hourly flow rate.

Inputs and outputs

Status of relays, pulse outputs, digital inputs and current outputs, with the name assigned to each connection.

Maintenance calendar

Tasks are scheduled by installation or by device and assigned to technicians; a reminder is sent by e-mail two days before the due date. Each task is shown as scheduled, due, overdue or completed.

Team and permissions

The main account has full access and creates the technicians’ accounts, each enabled only for the assigned installations and devices; the last login and activity of each technician are visible.

Reports and activity log

Reports on devices, tasks and technicians, downloadable in PDF or CSV with the customer’s logo; the log keeps the history of operations and disconnections.

Customisation

Logo, main colour and light or dark theme; the tiles on the main screen can be rearranged by dragging them. Two installations can be displayed side by side for comparison.

Guided registration

Each device is added through a guided procedure: the model is recognised automatically and associated with the installation, together with the technician to be contacted.

PLC integration

As an alternative to the portal, the Modbus RTU port allows integration into the plant supervision system.

NIMBUS portal: Real-time readings, counters and timers
Real-time readings, counters and timers
NIMBUS portal: Free chlorine and temperature trends
Free chlorine and temperature trends
NIMBUS portal: Set point and operating mode of each channel
Set point and operating mode of each channel
NIMBUS portal: Status of relays, pulses, inputs and mA outputs
Status of relays, pulses, inputs and mA outputs

Technical advice

Tell us the type of water to be monitored, the flow rate and the point where the turbid water is to be diverted: we will propose the most suitable installation, valves and accessories.

Contact

Tell us about your plant

Call or write to us: a technician will reply with a tailored proposal of controllers, pumps, probes and accessories.

What do you need?
Please enter your name.
Please enter a valid email address.
Please enter your message.

Describe your plant: type, water volume or flow rate, parameters to be controlled.

You must accept the privacy notice to continue.