Diaphragm dosing pump for constant dosing, the basic model of the V series: the flow rate is set on the pump by electronically adjusting the injection frequency, with a divider down to 1/10, without external signals.

  • Constant dosing
  • Up to 20 bar
  • Up to 16 l/h
  • 1/10 divider
VCO dosing pump
16l/hMaximum flow rate
20barMaximum pressure
17Configurations
IP65Protection rating
The model

VCO

VCO dosing pump
Basic model

VCO

Basic model for constant dosing without external controls.

  • Constant
  • Constant with divider

Pump head: PVDF or PP

Operation

Dosing modes

Constant

The pump doses at a constant injection frequency, proportional to the flow rate percentage set with the analogue selector (0 – 100%).

Constant with divider

Operation similar to constant dosing, with the selector adjustable between 0 and 10%: the maximum flow rate is reduced to as little as 1/10 of the rated value.

Technical data

Performance and configurations

The pump code is made up of the model name and the performance: maximum pressure in bar as two digits followed by the flow rate in l/h (VCO 0215 = 2 bar, 15 l/h). It is followed by the pump head code and the power supply code, listed in the tables at the end of this section. Performance varies with the working back pressure and with the characteristics of the chemical.

Manual air bleed

Suitable for most chemicals: the standard configuration for the most common applications.

CodeMax pressure (bar)Max flow rate (l/h)Tubing (mm)cc per strokePower draw at 230 VAC (W)
VCO 20012014 x 80.0916
VCO 18021824 x 80.1916
VCO 18041844 x 80.3722
VCO 15021524 x 60.1916
VCO 15041544 x 60.3716
VCO 15051554 x 60.4622
VCO 10041044 x 60.3716
VCO 10051054 x 60.4616
VCO 101010104 x 60.9322
VCO 0706764 x 60.5616
VCO 0501514 x 60.0916
VCO 05105104 x 60.9316
VCO 05125124 x 61.1122
VCO 0408484 x 60.7416
VCO 03103104 x 60.9316
VCO 02152156 x 81.3916
VCO 01161166 x 81.4816

Automatic air bleed

Required with chemicals that release gas (e.g. peroxides), to prevent the pump from becoming air-locked.

CodeMax pressure (bar)Max flow rate (l/h)Tubing (mm)
VA CO 18021824 x 8
VA CO 15011514 x 6
VA CO 15031534 x 6
VA CO 100.5100.54 x 6
VA CO 103.4103.44 x 6
VA CO 0704744 x 6
VA CO 057.557.54 x 6
VA CO 0509594 x 6
VA CO 045.545.54 x 6
VA CO 0307374 x 6
VA CO 02122126 x 8
VA CO 01131136 x 8

Technical specifications

SpecificationValue
Strokes per minute18 – 180
Maximum chemical viscosity100 cP
Ambient temperature10 – 45 °C
Chemical temperature0 – 50 °C
Transport and storage temperature−10 – 50 °C
Protection ratingIP65
Noise level74 dB(A)
Weight2.2 kg
HousingPPO
MountingVertical, wall or floor

Pump head codes

CodePump headSealsUse
1PVDFFKM BAll flow rates
3PVDFEPDMAll flow rates
4PVDFFKM BFlow rates up to 1 l/h
5PVDFEPDMFlow rates up to 1 l/h
VPPFKM BAll flow rates
DPPEPDMAll flow rates

In all versions: PVDF valves with ceramic balls, PTFE diaphragm, PE delivery tube and PVC suction tube.

Power supply codes

CodePower supply
00230 VAC, Schuko plug
0S230 VAC, Australian plug
01230 VAC, no plug
03115 VAC, US plug
0424 VAC, no plug
0512 VDC (some models only)
0724 VDC

Supplied with

  • PVDF foot filter
  • 0.3 bar PVDF injection valve
  • Delivery, suction and drain tubes (2 m each)
  • 5 × 20 time-delay fuse
  • Mounting kit
  • Operating manual

Pump head materials

Pump head in PVDF

PVDF

Suitable for most acids, for peroxides and for sodium hypochlorite (chlorine).

Pump head in PP

PP

Suitable for sodium hydroxide (caustic soda).

Learn more: chemical compatibility of materials →

Special versions

Special versions

In addition to the standard configuration, versions dedicated to particular applications are available; the performance of each is given in the technical data. The pages by application compare the suitable pumps of all the series.

VA and VMSA Series

VA and VMSA Series

Self-venting pump head, required with chemicals that release gas (e.g. sodium hypochlorite and peroxides): it vents the gas and prevents the pump from locking.

Technical support

Troubleshooting and error messages

The most frequent causes of malfunction and the corrective actions to check before contacting technical support.

Learn more: the pump does not prime and does not dose →

If the pump…

The pump strokes normally, but the chemical is not dosed
  • Air in the hydraulic circuitCheck fittings and tubing, tighten any loose ones and bleed the air.
  • Suction tube emptiedThe pump has lost its prime: repeat the priming procedure.
  • Foot filter cloggedRemove the lance or filter from the tank and clean it.
  • Gas released by the chemicalOpen the bleed valve to discharge the gas; if this recurs, fit a self-bleeding pump head.
No strokes, or weak and damped stroke
  • Valve balls blocked by crystallisation of the chemicalClean the valves and run the pump with 2 – 3 litres of water instead of the chemical; if the problem persists, replace the valves.
  • Injection valve cloggedReplace the injection valve.
The pump does not switch on
  • No power supplyCheck the mains connection and that the voltage matches the rated value.
  • Protection fuse blownReplace the fuse with one of the same rating.
  • Faulty circuit boardThe board must be replaced: contact our technical support service.

LEDs of the VCO and VCL

LEDMeaningAction
Red, 3 flashes per secondMains voltage too low.Check the power supply.
Red, 2 flashes per secondMains voltage too high.Check the power supply.
Steady redLevel alarm: chemical run out (VCL).Restore the chemical level in the tank.
Green, goes off at each strokePump running, normal frequency.No action required.
Orange, goes off at each strokePump running, frequency divided by 10.No action required.
Flashing every 2 secondsPump OFF, powered (green; orange in divide mode).No action required.

In the 12 – 24 V versions the LED is green only, with the same sequences.

Flow rate between 30 and 100%

Adjustment is linear between 30 and 100%: below 30% the actual flow rate may differ from the expected one and must therefore be checked.

Priming

Connect all the tubing, open the bleed valve and set the adjustment to 100%; start the pump and close the bleed valve as soon as the chemical comes out. With viscous liquids the operation can be assisted with a 20 cc syringe applied to the bleed port.

If the problem persists, contact us. Before sending the pump for servicing, empty the pump head of chemical and dry it.

Summary

Main features

Electronic flow rate adjustment

According to the operating mode and the set parameters, the pump automatically adapts the injection frequency to ensure the required dosing.

Priming button

A dedicated button allows the lines to be filled with the chemical to be dosed.

Versatile mounting

Vertical installation, or horizontal installation by means of a dedicated bracket.

Technical advice

Tell us about your application: our technical staff will recommend the most suitable model, configuration and accessories.

Contact

Tell us about your plant

Call or write to us: a technician will reply with a tailored proposal of controllers, pumps, probes and accessories.

What do you need?
Please enter your name.
Please enter a valid email address.
Please enter your message.

Describe your plant: type, water volume or flow rate, parameters to be controlled.

You must accept the privacy notice to continue.