VCO
Basic model for constant dosing without external controls.
- Constant
- Constant with divider
Diaphragm dosing pump for constant dosing, the basic model of the V series: the flow rate is set on the pump by electronically adjusting the injection frequency, with a divider down to 1/10, without external signals.
Basic model for constant dosing without external controls.
Pump head: PVDF or PP
The pump doses at a constant injection frequency, proportional to the flow rate percentage set with the analogue selector (0 – 100%).
Operation similar to constant dosing, with the selector adjustable between 0 and 10%: the maximum flow rate is reduced to as little as 1/10 of the rated value.
The pump code is made up of the model name and the performance: maximum pressure in bar as two digits followed by the flow rate in l/h (VCO 0215 = 2 bar, 15 l/h). It is followed by the pump head code and the power supply code, listed in the tables at the end of this section. Performance varies with the working back pressure and with the characteristics of the chemical.
Suitable for most chemicals: the standard configuration for the most common applications.
| Code | Max pressure (bar) | Max flow rate (l/h) | Tubing (mm) | cc per stroke | Power draw at 230 VAC (W) |
|---|---|---|---|---|---|
| VCO 2001 | 20 | 1 | 4 x 8 | 0.09 | 16 |
| VCO 1802 | 18 | 2 | 4 x 8 | 0.19 | 16 |
| VCO 1804 | 18 | 4 | 4 x 8 | 0.37 | 22 |
| VCO 1502 | 15 | 2 | 4 x 6 | 0.19 | 16 |
| VCO 1504 | 15 | 4 | 4 x 6 | 0.37 | 16 |
| VCO 1505 | 15 | 5 | 4 x 6 | 0.46 | 22 |
| VCO 1004 | 10 | 4 | 4 x 6 | 0.37 | 16 |
| VCO 1005 | 10 | 5 | 4 x 6 | 0.46 | 16 |
| VCO 1010 | 10 | 10 | 4 x 6 | 0.93 | 22 |
| VCO 0706 | 7 | 6 | 4 x 6 | 0.56 | 16 |
| VCO 0501 | 5 | 1 | 4 x 6 | 0.09 | 16 |
| VCO 0510 | 5 | 10 | 4 x 6 | 0.93 | 16 |
| VCO 0512 | 5 | 12 | 4 x 6 | 1.11 | 22 |
| VCO 0408 | 4 | 8 | 4 x 6 | 0.74 | 16 |
| VCO 0310 | 3 | 10 | 4 x 6 | 0.93 | 16 |
| VCO 0215 | 2 | 15 | 6 x 8 | 1.39 | 16 |
| VCO 0116 | 1 | 16 | 6 x 8 | 1.48 | 16 |
Required with chemicals that release gas (e.g. peroxides), to prevent the pump from becoming air-locked.
| Code | Max pressure (bar) | Max flow rate (l/h) | Tubing (mm) |
|---|---|---|---|
| VA CO 1802 | 18 | 2 | 4 x 8 |
| VA CO 1501 | 15 | 1 | 4 x 6 |
| VA CO 1503 | 15 | 3 | 4 x 6 |
| VA CO 100.5 | 10 | 0.5 | 4 x 6 |
| VA CO 103.4 | 10 | 3.4 | 4 x 6 |
| VA CO 0704 | 7 | 4 | 4 x 6 |
| VA CO 057.5 | 5 | 7.5 | 4 x 6 |
| VA CO 0509 | 5 | 9 | 4 x 6 |
| VA CO 045.5 | 4 | 5.5 | 4 x 6 |
| VA CO 0307 | 3 | 7 | 4 x 6 |
| VA CO 0212 | 2 | 12 | 6 x 8 |
| VA CO 0113 | 1 | 13 | 6 x 8 |
| Specification | Value |
|---|---|
| Strokes per minute | 18 – 180 |
| Maximum chemical viscosity | 100 cP |
| Ambient temperature | 10 – 45 °C |
| Chemical temperature | 0 – 50 °C |
| Transport and storage temperature | −10 – 50 °C |
| Protection rating | IP65 |
| Noise level | 74 dB(A) |
| Weight | 2.2 kg |
| Housing | PPO |
| Mounting | Vertical, wall or floor |
| Code | Pump head | Seals | Use |
|---|---|---|---|
| 1 | PVDF | FKM B | All flow rates |
| 3 | PVDF | EPDM | All flow rates |
| 4 | PVDF | FKM B | Flow rates up to 1 l/h |
| 5 | PVDF | EPDM | Flow rates up to 1 l/h |
| V | PP | FKM B | All flow rates |
| D | PP | EPDM | All flow rates |
In all versions: PVDF valves with ceramic balls, PTFE diaphragm, PE delivery tube and PVC suction tube.
| Code | Power supply |
|---|---|
| 00 | 230 VAC, Schuko plug |
| 0S | 230 VAC, Australian plug |
| 01 | 230 VAC, no plug |
| 03 | 115 VAC, US plug |
| 04 | 24 VAC, no plug |
| 05 | 12 VDC (some models only) |
| 07 | 24 VDC |
Suitable for most acids, for peroxides and for sodium hypochlorite (chlorine).
Suitable for sodium hydroxide (caustic soda).
In addition to the standard configuration, versions dedicated to particular applications are available; the performance of each is given in the technical data. The pages by application compare the suitable pumps of all the series.
Self-venting pump head, required with chemicals that release gas (e.g. sodium hypochlorite and peroxides): it vents the gas and prevents the pump from locking.
The most frequent causes of malfunction and the corrective actions to check before contacting technical support.
Learn more: the pump does not prime and does not dose →| LED | Meaning | Action |
|---|---|---|
| Red, 3 flashes per second | Mains voltage too low. | Check the power supply. |
| Red, 2 flashes per second | Mains voltage too high. | Check the power supply. |
| Steady red | Level alarm: chemical run out (VCL). | Restore the chemical level in the tank. |
| Green, goes off at each stroke | Pump running, normal frequency. | No action required. |
| Orange, goes off at each stroke | Pump running, frequency divided by 10. | No action required. |
| Flashing every 2 seconds | Pump OFF, powered (green; orange in divide mode). | No action required. |
In the 12 – 24 V versions the LED is green only, with the same sequences.
Adjustment is linear between 30 and 100%: below 30% the actual flow rate may differ from the expected one and must therefore be checked.
Connect all the tubing, open the bleed valve and set the adjustment to 100%; start the pump and close the bleed valve as soon as the chemical comes out. With viscous liquids the operation can be assisted with a 20 cc syringe applied to the bleed port.
If the problem persists, contact us. Before sending the pump for servicing, empty the pump head of chemical and dry it.
According to the operating mode and the set parameters, the pump automatically adapts the injection frequency to ensure the required dosing.
A dedicated button allows the lines to be filled with the chemical to be dosed.
Vertical installation, or horizontal installation by means of a dedicated bracket.
Tell us about your application: our technical staff will recommend the most suitable model, configuration and accessories.
Call or write to us: a technician will reply with a tailored proposal of controllers, pumps, probes and accessories.