VCL
For constant dosing, with input for tank level control.
- Constant
- Constant with divider
Diaphragm dosing pump for constant dosing with tank level control: the level probe, supplied as standard in the foot filter, stops the pump when the chemical runs out and the LED signals the alarm. The flow rate is adjusted electronically through the injection frequency, with a divider down to 1/10.
The VCL is the V series constant-dosing pump with the level probe as standard, fitted in the foot filter: when the chemical runs out, the pump stops and the LED signals the alarm. Compared with the VCO it therefore adds protection against dry running, with the same maximum flow rate of 16 l/h and the same pressure of 20 bar.
For constant dosing, with input for tank level control.
Pump head: PVDF or PP
The pump doses at a constant injection frequency, proportional to the flow rate percentage set with the analogue selector (0 – 100%).
Operation similar to constant dosing, with the selector adjustable between 0 and 10%: the maximum flow rate is reduced to as little as 1/10 of the rated value.
The pump code is made up of the model name and the performance: maximum pressure in bar as two digits followed by the flow rate in l/h (VCL 0215 = 2 bar, 15 l/h). It is followed by the pump head code and the power supply code, listed in the tables at the end of this section. Performance varies with the working back pressure and with the characteristics of the chemical.
Suitable for most chemicals: the standard configuration for the most common applications.
| Code | Max pressure (bar) | Max flow rate (l/h) | Tubing (mm) | cc per stroke | Power draw at 230 VAC (W) |
|---|---|---|---|---|---|
| VCL 2001 | 20 | 1 | 4 x 8 | 0.09 | 16 |
| VCL 1802 | 18 | 2 | 4 x 8 | 0.19 | 16 |
| VCL 1804 | 18 | 4 | 4 x 8 | 0.37 | 22 |
| VCL 1502 | 15 | 2 | 4 x 6 | 0.19 | 16 |
| VCL 1504 | 15 | 4 | 4 x 6 | 0.37 | 16 |
| VCL 1505 | 15 | 5 | 4 x 6 | 0.46 | 22 |
| VCL 1004 | 10 | 4 | 4 x 6 | 0.37 | 16 |
| VCL 1005 | 10 | 5 | 4 x 6 | 0.46 | 16 |
| VCL 1010 | 10 | 10 | 4 x 6 | 0.93 | 22 |
| VCL 0706 | 7 | 6 | 4 x 6 | 0.56 | 16 |
| VCL 0501 | 5 | 1 | 4 x 6 | 0.09 | 16 |
| VCL 0510 | 5 | 10 | 4 x 6 | 0.93 | 16 |
| VCL 0512 | 5 | 12 | 4 x 6 | 1.11 | 22 |
| VCL 0408 | 4 | 8 | 4 x 6 | 0.74 | 16 |
| VCL 0310 | 3 | 10 | 4 x 6 | 0.93 | 16 |
| VCL 0215 | 2 | 15 | 6 x 8 | 1.39 | 16 |
| VCL 0116 | 1 | 16 | 6 x 8 | 1.48 | 16 |
Required with chemicals that release gas (e.g. peroxides), to prevent the pump from becoming air-locked.
| Code | Max pressure (bar) | Max flow rate (l/h) | Tubing (mm) |
|---|---|---|---|
| VA CL 1802 | 18 | 2 | 4 x 8 |
| VA CL 1501 | 15 | 1 | 4 x 6 |
| VA CL 1503 | 15 | 3 | 4 x 6 |
| VA CL 100.5 | 10 | 0.5 | 4 x 6 |
| VA CL 103.4 | 10 | 3.4 | 4 x 6 |
| VA CL 0704 | 7 | 4 | 4 x 6 |
| VA CL 057.5 | 5 | 7.5 | 4 x 6 |
| VA CL 0509 | 5 | 9 | 4 x 6 |
| VA CL 045.5 | 4 | 5.5 | 4 x 6 |
| VA CL 0307 | 3 | 7 | 4 x 6 |
| VA CL 0212 | 2 | 12 | 6 x 8 |
| VA CL 0113 | 1 | 13 | 6 x 8 |
| Specification | Value |
|---|---|
| Strokes per minute | 18 – 180 |
| Maximum chemical viscosity | 100 cP |
| Ambient temperature | 10 – 45 °C |
| Chemical temperature | 0 – 50 °C |
| Transport and storage temperature | −10 – 50 °C |
| Protection rating | IP65 |
| Noise level | 74 dB(A) |
| Weight | 2.2 kg |
| Housing | PPO |
| Mounting | Vertical, wall or floor |
| Code | Pump head | Seals | Use |
|---|---|---|---|
| 1 | PVDF | FKM B | All flow rates |
| 3 | PVDF | EPDM | All flow rates |
| 4 | PVDF | FKM B | Flow rates up to 1 l/h |
| 5 | PVDF | EPDM | Flow rates up to 1 l/h |
| V | PP | FKM B | All flow rates |
| D | PP | EPDM | All flow rates |
In all versions: PVDF valves with ceramic balls, PTFE diaphragm, PE delivery tube and PVC suction tube.
| Code | Power supply |
|---|---|
| 00 | 230 VAC, Schuko plug |
| 0S | 230 VAC, Australian plug |
| 01 | 230 VAC, no plug |
| 03 | 115 VAC, US plug |
| 04 | 24 VAC, no plug |
| 05 | 12 VDC (some models only) |
| 07 | 24 VDC |
Suitable for most acids, for peroxides and for sodium hypochlorite (chlorine).
Suitable for sodium hydroxide (caustic soda).
In addition to the standard configuration, versions dedicated to particular applications are available; the performance of each is given in the technical data. The pages by application compare the suitable pumps of all the series.
Self-venting pump head, required with chemicals that release gas (e.g. sodium hypochlorite and peroxides): it vents the gas and prevents the pump from locking.
The most frequent causes of malfunction and the corrective actions to check before contacting technical support.
Learn more: the pump does not prime and does not dose →| LED | Meaning | Action |
|---|---|---|
| Red, 3 flashes per second | Mains voltage too low. | Check the power supply. |
| Red, 2 flashes per second | Mains voltage too high. | Check the power supply. |
| Steady red | Level alarm: chemical run out (VCL). | Restore the chemical level in the tank. |
| Green, goes off at each stroke | Pump running, normal frequency. | No action required. |
| Orange, goes off at each stroke | Pump running, frequency divided by 10. | No action required. |
| Flashing every 2 seconds | Pump OFF, powered (green; orange in divide mode). | No action required. |
In the 12 – 24 V versions the LED is green only, with the same sequences.
Adjustment is linear between 30 and 100%: below 30% the actual flow rate may differ from the expected one and must therefore be checked.
Connect all the tubing, open the bleed valve and set the adjustment to 100%; start the pump and close the bleed valve as soon as the chemical comes out. With viscous liquids the operation can be assisted with a 20 cc syringe applied to the bleed port.
If the problem persists, contact us. Before sending the pump for servicing, empty the pump head of chemical and dry it.
According to the operating mode and the set parameters, the pump automatically adapts the injection frequency to ensure the required dosing.
The pump is supplied with a low-level probe for the tank: when the chemical runs out, it shows the alarm on the display and activates the corresponding output.
A dedicated button allows the lines to be filled with the chemical to be dosed.
Vertical installation, or horizontal installation by means of a dedicated bracket.
Tell us about your application: our technical staff will recommend the most suitable model, configuration and accessories.
Call or write to us: a technician will reply with a tailored proposal of controllers, pumps, probes and accessories.