Skip to content
Motor-driven piston dosing pump

Prius P MF

Multifunction motor-driven piston dosing pump with single-phase power supply and colour display. The flow rate is adjusted by the volume of each injection, with the stroke length knob, and by the stroke frequency, in constant dosing or in proportion to a pulse-output water meter, to 0-4/20 mA and 0-10 V signals, in ppm or in batches. The piston is made of ceramic with a PP pump head, or of stainless steel with an AISI 316L pump head.

  • Multifunction with colour display
  • Up to 320 l/h
  • Up to 10 bar
  • Single-phase 230 or 115 VAC
Prius P MF dosing pump
320l/hMaximum flow rate
10barMaximum pressure
20Configurations
IP55Protection rating
The model

Prius P MF

Prius P MF dosing pump
Multifunction

Prius P MF

Constant dosing or dosing proportional to 0-4/20 mA current loop or 0-10 V signals or to a pulse-output water meter. Flow sensor on the version with SEFL input.

  • Constant (litres/hour)
  • PPM
  • Percentage
  • Millilitres per quintal (100 kg)
  • Volt
  • Pulses
  • Batch
  • mA
  • Timer
  • Pause / work
  • External constant
Available versions
Prius P MF SS Prius P MF SSAISI 316L stainless steel pump head and AISI 420 stainless steel piston.

Pump head: PP with ceramic piston, or AISI 316L with AISI 420 piston

Power supply: single-phase 230 VAC 50/60 Hz or 115 VAC

Operation

Dosing modes

Constant (litres/hour)

The pump doses at a constant frequency, according to the flow rate set in litres/hour.

External constant

When the run contact closes, the pump doses the set quantity of chemical.

Pause / work

The pump runs the programmed cycle: during the WORK time it doses the set quantity of chemical; during the PAUSE time dosing is suspended.

Pulses

The pump doses in proportion to the pulses received from an external controller.

PPM

Dosing is calculated from the pulses of the pulse-output water meter and the set PPM value; the concentration of the chemical and the volume per stroke can be programmed.

Millilitres per quintal (100 kg)

Dosing is calculated from the pulses of the pulse-output water meter and the set MLQ value (millilitres per quintal, i.e. per 100 kg).

Batch

A pulse from an external contact starts the dosing of the set quantity; pause and work cycles can be programmed.

mA

The 0-4/20 mA current loop signal controls dosing proportionally, between the set minimum and maximum values.

Volt

The 0-10 V voltage signal controls dosing proportionally, between the set minimum and maximum values.

Timer

Up to 16 weekly on/off time slots can be programmed, during which the pump doses the set quantity of chemical.

Colour display

Colour-coded status indication

The display colour changes according to the operating status, so that an alarm can be recognised even from a distance.

Display Green

Green

Normal operation according to the set parameters, no active alarms.

Display Yellow

Yellow

Non-blocking alarm, for example waiting for an external signal.

Display Red

Red

Blocking alarm, for example the chemical in the tank running out.

Display White

White

Pump stopped by an external control signal (stand-by).

Remote control

Remote control

The pump can be integrated into your control system via Modbus RTU, or it can send a read-only 0-4/20 mA current loop signal.

Integrated Modbus RTU

Integration into your PLC: all pump parameters can be managed from your control interface.

Optional

0-4/20 mA current loop output

Current signal proportional to the instantaneous flow rate, to be fed to your PLC / SCADA for remote monitoring of operation (read-only).

Optional
Technical data

Performance and configurations

The pump code is made up of the model name and the performance: maximum pressure in bar as two digits followed by the flow rate in l/h (Prius P MF 1024 = 10 bar, 24 l/h). The flow rate depends on the piston diameter and on the number of strokes per minute; with viscous products a lower number of strokes per minute is recommended.

Manual air bleed

Manual air bleed, suitable for most chemicals. Pistons from 14 to 50 mm, ceramic with a PP pump head or stainless steel with an AISI 316L pump head.

CodeMax pressure (bar)Max flow rate (l/h)Strokes / minuteMotor (kW)Piston diameter (mm)
Prius P MF 102410241750.3714
Prius P MF 10131013940.3714
Prius P MF 10101010700.3714
Prius P MF 1005105350.3714
Prius P MF 108010801750.3725
Prius P MF 10431043940.3725
Prius P MF 10321032700.3725
Prius P MF 10161016350.3725
Prius P MF 10130101301750.3732
Prius P MF 10701070940.3732
Prius P MF 10521052700.3732
Prius P MF 10261026350.3732
Prius P MF 10210102101750.3740
Prius P MF 1011310113940.3740
Prius P MF 10841084700.3740
Prius P MF 10421042350.3740
Prius P MF 10320103201750.3750
Prius P MF 1017210172940.3750
Prius P MF 1012810128700.3750
Prius P MF 10641064350.3750

Technical specifications

SpecificationValue
Power supplySingle-phase 230 VAC 50/60 Hz or 115 VAC
Ambient temperature−10 – 40 °C
Chemical temperature with PP pump head−10 – 40 °C
Chemical temperature with stainless steel pump head−10 – 90 °C
Piston stroke15 mm
PistonSIALOX 96 ceramic with PP pump head; AISI 420 stainless steel with AISI 316L pump head
Dosing accuracy± 5% at rated pressure
Noise level78 dB(A) ± 5 dB
Maximum suction lift3 m
Gearbox oil0.3 l
MotorInsulation class F, IE1 efficiency
Maximum current draw2.5 A at 230 VAC; 5 A at 115 VAC (575 VA)
Fuse6.3 A slow-blow at 230 VAC; 8 A slow-blow at 115 VAC
Alarm output24 VAC, 1 A contact
Relative humidity95%, non-condensing
Weight16 kg with PP pump head; 25 kg with stainless steel pump head

The maximum chemical temperature with the stainless steel pump head may be exceeded for a limited time, no longer than 15 minutes, during sterilisation or washing with hot water.

Hydraulic connections

Piston diameterPP with ceramic pistonAISI 316L with AISI 420 piston
14, 25 and 32 mmG 1/2″, 12 × 18 tubeR 1/2″
40 and 50 mmG 3/4″, 18 mm i.d. tubeR 3/4″

Installation kit A is included in the supply with a PP pump head and pistons from 14 to 32 mm: 1/2″ foot filter with 13 mm i.d. hose connector, 3/4″ injection valve and delivery and suction tubes, 13 × 16 PVDF or 12 × 18 PVC. Kit B, optional for the 40 and 50 mm pistons, includes the 1 1/2″ foot filter with 18 mm i.d. hose connector and the 1 1/2″ injection valve. No installation accessories are provided with the stainless steel pump head.

Pump codes

CodeComponentVersion
FElectronicsMultifunction, 230 VAC power supply
1ElectronicsMultifunction, 115 VAC power supply
DPump head and pistonPP with SIALOX 96 ceramic piston
EPump head and pistonAISI 316L with AISI 420 piston
VO-ringFKM B
DO-ringEPDM (Dutral)
WO-ringWAX
1Reduction ratio8:1
2Reduction ratio15:1
4Reduction ratio20:1
1Motor0.18 kW
2Motor0.37 kW

Compatible lubricating oils

BrandOil
MobilMobilgear 632
ShellOmala Oil 320
BPEnergol GR-XP 320
IPMellana Oil 320
EssoSpartan EP 320
AgipBlasia 320

The pump is supplied with the oil already filled; the level is checked through the sight glass and the oil must be changed at least once a year.

Construction

  • Aluminium housing with epoxy coating
  • IP55 protection rating (IP65 optional)

Supplied with

  • Level probe
  • Input and stand-by cable
  • Alarm cable
  • Gearbox oil, already filled
  • Installation kit A with PP pump head and pistons from 14 to 32 mm

Wetted parts

PP pump head and SIALOX96 ceramic piston

PP + ceramic

PP pump head and SIALOX96 ceramic piston.

AISI 316L stainless steel pump head and AISI 420 stainless steel piston

AISI 316L + AISI 420

AISI 316L stainless steel pump head and AISI 420 stainless steel piston.

Learn more: chemical compatibility of materials →

Technical support

Troubleshooting and error messages

The most frequent causes of malfunction and the corrective actions to check before contacting technical support.

Learn more: the pump does not prime and does not dose →

If the pump…

Insufficient or no flow rate
  • Air in the pump head or in the suction tubePrime the pump until all the air has been expelled.
  • Suction valve or tube obstructed or not sealingClean or replace the suction valve; replace the tube.
  • Foot filter cloggedClean the filter.
  • Excessive suction lift relative to the tankReduce the suction lift.
  • High-viscosity liquidUse a larger-diameter suction tube.
Overheating of the motor and pump head
  • Insufficient oil levelTop up the oil: the pump must never run without lubricant.
  • Operating pressure above the rated valueInstall a pressure relief valve.
  • Delivery line obstructed or blockedClear the delivery tube.
  • Incorrect electrical connectionsReconnect the pump according to the instructions in the manual.
Liquid leaking from the pump head
  • Damaged piston O-ringContact our technical support service for replacement.
Display on but showing nothing
  • Display battery flatReplace the 3 V battery located on the circuit board behind the display.

Display of the Prius P MF

MessageMeaningAction
LEVELChemical in the tank has run out.Restore the chemical level in the tank.
OVER FLOWThe required flow rate exceeds the rated value.Check the settings and the flow rate, then switch the pump off and on again.
HIGH VOLTSupply voltage above the permitted limits.Check that the voltage matches the rating plate data; if the pump has locked out, switch it off and on again.
LOW VOLTSupply voltage below the permitted limits; after 5 alarms within two minutes the pump locks out.Check the mains voltage, then switch the pump off and on again.
ANOMALIA IMPIANTOSudden stop of the pump or motor (system fault).Identify and eliminate the cause of the stop, then switch the pump off and on again.
SEFLThe flow sensor does not detect the passage of product within the set time (factory setting: 5 seconds).Check the sensor and the delivery line, then switch the pump off and on again.

Red display: alarm; yellow: warning; green: normal operation; white: stand-by or OFF. Active alarms can be viewed under SETUP › INFO › ALARMS.

First start-up

Start the pump with the stroke length set to 20% and minimum back pressure; after about 5 minutes increase it gradually. If the pressure exceeds the rated value, stop the motor immediately.

Oil

Check the level using the dedicated indicator and never run the pump without oil; change it every 8,000 – 10,000 operating hours and in any case at least once a year.

Periodic checks

Every three months check bolts and seals; once a year check that flow rate, pressure and power match the rating plate data. With abrasive or corrosive chemicals, shorten the intervals.

If the problem persists, contact us. Before sending the pump for servicing, empty the pump head of chemical and dry it.

Summary

Main features

Electronic flow rate adjustment

According to the operating mode and the set parameters, the pump automatically adapts the injection frequency to ensure the required dosing.

Mechanical flow rate adjustment

The knob reduces the stroke length of the piston, i.e. the volume of each injection and, consequently, the maximum flow rate. This offers two advantages:
Linear dosing: a high number of small-volume injections promotes mixing of the chemical into the water flow and avoids concentration peaks.
Accuracy at low dosing rates: with a 10 l/h pump required to dose 1 l/h, reducing the stroke length to 50% brings the maximum flow rate down to 5 l/h and doubles the injection frequency. Particularly suitable in combination with the pulse-output water meter.

Digital display

The integrated LCD display allows the pump to be programmed and its operating status to be monitored at all times.

Level control

The pump is supplied with a low-level probe for the tank: when the chemical runs out, it shows the alarm on the display and activates the corresponding output.

Stand-by

Pump start and stop can be controlled remotely by means of a run/stop contact from a PLC or another source.

Flow sensor (SEFL version)

A flow sensor can be connected to check every single injection: if one or more injections are missed, the pump performs an automatic re-priming and recovers the lost injections; if this fails, it activates the alarm output.

Alarm output

In the event of a fault, a volt-free contact is activated, configurable as normally open (N.O.) or normally closed (N.C.), to drive a visual or audible signalling device, send an SMS or report the event to a PLC.

Priming button

A dedicated button allows the lines to be filled with the chemical to be dosed.

Versatile mounting

Horizontal installation, or vertical installation by means of a dedicated bracket.

Technical advice

Tell us about your application: our technical staff will recommend the most suitable model, configuration and accessories.

Contact

Tell us about your plant

Call or write to us: a technician will reply with a tailored proposal of controllers, pumps, probes and accessories.

What do you need?
Please enter your name.
Please enter a valid email address.
Please enter your message.

Describe your plant: type, water volume or flow rate, parameters to be controlled.

You must accept the privacy notice to continue.