Technical data
Performance and configurations
The pump code is made up of the model name and the performance: maximum pressure in bar as two digits followed by the flow rate in l/h (Prius D MF 1060 = 10 bar, 60 l/h). Performance depends on the working back pressure, the number of strokes per minute and the characteristics of the chemical; with viscous products a lower number of strokes per minute is recommended.
Manual air bleed
Manual air bleed, suitable for most chemicals. NM, TM and UMS pump heads in PVDF, PP or AISI 316L stainless steel.
| Code | Max pressure (bar) | Max flow rate (l/h) | Strokes / minute | Motor (kW) | Pump head | Stroke (mm) |
| Prius D MF 1060 | 10 | 60 | 175 | 0.37 | NM | 3 |
|---|
| Prius D MF 1030 | 10 | 30 | 94 | 0.37 | NM | 3 |
|---|
| Prius D MF 1024 | 10 | 24 | 70 | 0.37 | NM | 3 |
|---|
| Prius D MF 1012 | 10 | 12 | 35 | 0.37 | NM | 3 |
|---|
| Prius D MF 1016 | 10 | 16 | 35 | 0.37 | NM | 4 |
|---|
| Prius D MF 10105 | 10 | 105 | 175 | 0.37 | TM | 3 |
|---|
| Prius D MF 1056 | 10 | 56 | 94 | 0.37 | TM | 3 |
|---|
| Prius D MF 1042 | 10 | 42 | 70 | 0.37 | TM | 3 |
|---|
| Prius D MF 1021 | 10 | 21 | 35 | 0.37 | TM | 3 |
|---|
| Prius D MF 07160 | 7 | 160 | 175 | 0.37 | TM | 4 |
|---|
| Prius D MF 0786 | 7 | 86 | 94 | 0.37 | TM | 4 |
|---|
| Prius D MF 0764 | 7 | 64 | 70 | 0.37 | TM | 4 |
|---|
| Prius D MF 0732 | 7 | 32 | 35 | 0.37 | TM | 4 |
|---|
| Prius D MF 05240 | 5 | 240 | 175 | 0.37 | TM | 6 |
|---|
| Prius D MF 05128 | 5 | 128 | 94 | 0.37 | TM | 6 |
|---|
| Prius D MF 0596 | 5 | 96 | 70 | 0.37 | TM | 6 |
|---|
| Prius D MF 0548 | 5 | 48 | 35 | 0.37 | TM | 6 |
|---|
| Prius D MF 021000 | 2 | 1,000 | 175 | 0.37 | UMS | 10 |
|---|
| Prius D MF 051000 | 5 | 1,000 | 175 | 0.55 | UMS | 10 |
|---|
| Prius D MF 04520 | 4 | 520 | 94 | 0.37 | UMS | 10 |
|---|
| Prius D MF 05390 | 5 | 390 | 70 | 0.37 | UMS | 10 |
|---|
| Prius D MF 05180 | 5 | 180 | 35 | 0.37 | UMS | 10 |
|---|
| Prius D MF 05350 | 5 | 350 | 175 | 0.37 | UMS | 4 |
|---|
| Prius D MF 05188 | 5 | 188 | 94 | 0.37 | UMS | 4 |
|---|
| Prius D MF 05140 | 5 | 140 | 70 | 0.37 | UMS | 4 |
|---|
| Prius D MF 0570 | 5 | 70 | 35 | 0.37 | UMS | 4 |
|---|
| Prius D MF 05440 | 5 | 440 | 175 | 0.37 | UMS | 5 |
|---|
| Prius D MF 05236 | 5 | 236 | 94 | 0.37 | UMS | 5 |
|---|
| Prius D MF 05176 | 5 | 176 | 70 | 0.37 | UMS | 5 |
|---|
| Prius D MF 0588 | 5 | 88 | 35 | 0.37 | UMS | 5 |
|---|
| Prius D MF 05530 | 5 | 530 | 175 | 0.37 | UMS | 6 |
|---|
| Prius D MF 05284 | 5 | 284 | 94 | 0.37 | UMS | 6 |
|---|
| Prius D MF 05212 | 5 | 212 | 70 | 0.37 | UMS | 6 |
|---|
| Prius D MF 05106 | 5 | 106 | 35 | 0.37 | UMS | 6 |
|---|
| Prius D MF 03750 | 3 | 750 | 175 | 0.37 | UMS | 8 |
|---|
| Prius D MF 05380 | 5 | 380 | 94 | 0.37 | UMS | 8 |
|---|
| Prius D MF 05290 | 5 | 290 | 70 | 0.37 | UMS | 8 |
|---|
| Prius D MF 05141 | 5 | 141 | 35 | 0.37 | UMS | 8 |
The 5 bar, 1,000 l/h configuration, with a 0.55 kW motor, is available with a PVDF or PP pump head.
Technical specifications
| Specification | Value |
| Power supply | Single-phase 230 VAC 50/60 Hz or 115 VAC |
| Ambient temperature | −10 – 40 °C |
| Chemical temperature with PVDF pump head | −10 – 65 °C |
| Chemical temperature with PP pump head | −10 – 40 °C |
| Chemical temperature with AISI 316L pump head | −10 – 90 °C |
| Noise level | 78 dB(A) ± 5 dB |
| Maximum suction lift | 3 m |
| Gearbox oil | 0.3 l |
| Maximum viscosity | Up to 50,000 cP, depending on the pump head |
| Dosing accuracy | ± 5% at rated pressure |
| Maximum current draw | 2.5 A at 230 VAC; 5 A at 115 VAC (575 VA) |
| Fuse | 6.3 A slow-blow at 230 VAC; 8 A slow-blow at 115 VAC |
| Alarm output | 24 VAC, 1 A contact |
| Motor | Insulation class F, IE1 efficiency |
| Relative humidity | 95%, non-condensing |
| Recommended diaphragm replacement | Every 10,000 operating hours |
| Weight with UM pump head | 16 kg in PP; 25 kg in stainless steel |
The maximum chemical temperatures may be exceeded for a limited time, no longer than 15 minutes, during sterilisation or washing with hot water.
Hydraulic connections
| Pump head | PVDF and PP | AISI 316L |
| NM | G 1/2″, 13 mm i.d. tube | R 1/2″ |
| TM, 3 – 4 mm stroke | G 3/4″, 13 mm i.d. tube | R 3/4″ |
| TM, 6 mm stroke | G 3/4″, 18 mm i.d. tube | R 3/4″ |
| UMS | G 1 1/2″, 30 mm i.d. tube | R 1″ |
Pump head material codes
| Code | Pump head |
| K | PVDF |
| P | PP |
| S | AISI 316L |
The letter follows the performance in the pump code (PDMF 010060 K…).
Electronics codes
| Code | Electronics |
| MF | Multifunction, 230 VAC power supply |
| M1 | Multifunction, 115 VAC power supply |
| MM | Multifunction with Modbus RTU |
Seal and gearbox codes
| Code | Component | Version |
| V | O-ring | FKM B |
| D | O-ring | EPDM (Dutral) |
| 1 | Reduction ratio | 8:1 |
| 2 | Reduction ratio | 15:1 |
| 3 | Reduction ratio | 10:1 |
| 4 | Reduction ratio | 20:1 |
| 5 | Reduction ratio | 40:1 |
The reduction ratio determines the number of strokes per minute: 8:1 corresponds to 175 strokes, 15:1 to 94, 20:1 to 70 and 40:1 to 35 strokes per minute with a 50 Hz power supply.
Compatible lubricating oils
| Brand | Oil |
| Mobil | Mobilgear 632 |
| Shell | Omala Oil 320 |
| BP | Energol GR-XP 320 |
| IP | Mellana Oil 320 |
| Esso | Spartan EP 320 |
| Agip | Blasia 320 |
The pump is supplied with the oil already filled; the level is checked through the sight glass and the oil must be changed at least once a year.
Construction
- Aluminium housing with epoxy coating
- IP55 protection rating (IP65 optional)
- PTFE diaphragm
Supplied with
- Level probe with foot filter
- Level probe cable
- Gearbox oil, already filled
- Blind plug for transport
Pump head materials
PVDF
Suitable for most acids, for peroxides and for sodium hypochlorite (chlorine).
PP
Suitable for sodium hydroxide (caustic soda).
AISI 316L
Suitable for peracetic acid and sodium hydroxide.
PMMA
Suitable for medium and high viscosity substances.
Learn more: chemical compatibility of materials →