Skip to content
Motor-driven dosing pump

Prius D AP MF

Multifunction motor-driven dosing pump with PTFE diaphragm, designed to inject the chemical into high-pressure lines, up to 100 bar. It combines mechanical stroke length adjustment with electronic adjustment of the stroke frequency, for constant dosing or dosing proportional to a pulse-output water meter and to 0-4/20 mA or 0-10 V signals. The colour display shows the pump status and the alarms.

  • Up to 100 bar
  • Up to 91 l/h
  • Multifunction with colour display
  • Single-phase 230 or 115 VAC
Prius D AP MF dosing pump
91l/hMaximum flow rate
100barMaximum pressure
18Configurations
IP55Protection rating
The model

Prius D AP MF

Prius D AP MF dosing pump
High pressure · multifunction

Prius D AP MF

Multifunction model for high-pressure dosing, up to 100 bar, constant or proportional to 0-4/20 mA current loop or 0-10 V signals or to a pulse-output water meter. Flow sensor on the version with SEFL input.

  • Constant
  • Constant (litres/hour)
  • PPM
  • Percentage
  • Millilitres per quintal (100 kg)
  • Volt
  • Pulses
  • Batch
  • mA
  • Timer
  • Pause / work
  • External constant

Pump head: PVDF or AISI 316L

Power supply: single-phase 230 VAC 50/60 Hz or 115 VAC

Operation

Dosing modes

Constant

The pump doses at a constant frequency, according to the flow rate percentage set with the knob that adjusts the stroke length of the diaphragm.

Constant (litres/hour)

The pump doses at a constant frequency, according to the flow rate set in litres/hour.

External constant

When the run contact closes, the pump doses the set quantity of chemical.

Pause / work

The pump runs the programmed cycle: during the WORK time it doses the set quantity of chemical; during the PAUSE time dosing is suspended.

Pulses

The pump doses in proportion to the pulses received from an external controller.

PPM

Dosing is calculated from the pulses of the pulse-output water meter and the set PPM value; the concentration of the chemical and the volume per stroke can be programmed.

Millilitres per quintal (100 kg)

Dosing is calculated from the pulses of the pulse-output water meter and the set MLQ value (millilitres per quintal, i.e. per 100 kg).

Batch

A pulse from an external contact starts the dosing of the set quantity; pause and work cycles can be programmed.

mA

The 0-4/20 mA current loop signal controls dosing proportionally, between the set minimum and maximum values.

Volt

The 0-10 V voltage signal controls dosing proportionally, between the set minimum and maximum values.

Timer

Up to 16 weekly on/off time slots can be programmed, during which the pump doses the set quantity of chemical.

Colour display

Colour-coded status indication

The display colour changes according to the operating status, so that an alarm can be recognised even from a distance.

Display Green

Green

Normal operation according to the set parameters, no active alarms.

Display Yellow

Yellow

Non-blocking alarm, for example waiting for an external signal.

Display Red

Red

Blocking alarm, for example the chemical in the tank running out.

Display White

White

Pump stopped by an external control signal (stand-by).

Remote control

Remote control

The pump can be integrated into your control system via Modbus RTU, or it can send a read-only 0-4/20 mA current loop signal.

Integrated Modbus RTU

Integration into your PLC: all pump parameters can be managed from your control interface.

Optional

0-4/20 mA current loop output

Current signal proportional to the instantaneous flow rate, to be fed to your PLC / SCADA for remote monitoring of operation (read-only).

Optional
Technical data

Performance and configurations

The pump code is made up of the model name and the performance: maximum pressure in bar as two digits followed by the flow rate in l/h (Prius D AP MF 5017 = 50 bar, 17 l/h). Performance depends on the working back pressure, the number of strokes per minute and the characteristics of the chemical; with viscous products a lower number of strokes per minute is recommended.

Manual air bleed

Manual air bleed, suitable for most chemicals. LM AP, MM AP, NM AP, SM AP and TM AP high-pressure pump heads.

CodeMax pressure (bar)Max flow rate (l/h)Strokes / minuteMotor (kW)Pump headStroke (mm)
Prius D AP MF 1000410041750.37LM AP1.5
Prius D AP MF 100021002940.37LM AP1.5
Prius D AP MF 1001.51001.5700.37LM AP1.5
Prius D AP MF 501750171750.37MM AP2
Prius D AP MF 5009509940.37MM AP2
Prius D AP MF 5005505700.37MM AP2
Prius D AP MF 502.5502.5350.37MM AP2
Prius D AP MF 302830281750.37NM AP2
Prius D AP MF 30153015940.37NM AP2
Prius D AP MF 30103010700.37NM AP2
Prius D AP MF 3005305350.37NM AP2
Prius D AP MF 307630761750.37SM AP4
Prius D AP MF 30413041940.37SM AP4
Prius D AP MF 30303030700.37SM AP4
Prius D AP MF 30143014350.37SM AP4
Prius D AP MF 20912091940.37TM AP6
Prius D AP MF 20682068700.37TM AP6
Prius D AP MF 20342034350.37TM AP6

Technical specifications

SpecificationValue
Power supplySingle-phase 230 VAC 50/60 Hz or 115 VAC
Ambient temperature−10 – 40 °C
Chemical temperature with PVDF pump head−10 – 65 °C
Chemical temperature with AISI 316L pump head−10 – 90 °C
Noise level78 dB(A) ± 5 dB
Maximum suction lift3 m
Gearbox oil0.3 l
Dosing accuracy± 5% at rated pressure
Maximum current draw2.5 A at 230 VAC; 5 A at 115 VAC (575 VA)
Fuse6.3 A slow-blow at 230 VAC; 8 A slow-blow at 115 VAC
Alarm output24 VAC, 1 A contact
MotorInsulation class F, IE1 efficiency
Relative humidity95%, non-condensing
Recommended diaphragm replacementEvery 10,000 operating hours

The maximum chemical temperatures may be exceeded for a limited time, no longer than 15 minutes, during sterilisation or washing with hot water.

Hydraulic connections

Pump headMaterialConnection
LM APAISI 316LR 3/8″
MM APAISI 316LR 1/2″
NM APAISI 316LR 1/2″
SM APAISI 316LR 1/2″
TM APAISI 316LR 3/4″

Pump head material codes

CodePump head
KPVDF
SAISI 316L

The letter follows the performance in the pump code (PDMF 010060 K…).

Electronics codes

CodeElectronics
MFMultifunction, 230 VAC power supply
M1Multifunction, 115 VAC power supply
MMMultifunction with Modbus RTU

Seal and gearbox codes

CodeComponentVersion
VO-ringFKM B
DO-ringEPDM (Dutral)
1Reduction ratio8:1
2Reduction ratio15:1
3Reduction ratio10:1
4Reduction ratio20:1
5Reduction ratio40:1

The reduction ratio determines the number of strokes per minute: 8:1 corresponds to 175 strokes, 15:1 to 94, 20:1 to 70 and 40:1 to 35 strokes per minute with a 50 Hz power supply.

Compatible lubricating oils

BrandOil
MobilMobilgear 632
ShellOmala Oil 320
BPEnergol GR-XP 320
IPMellana Oil 320
EssoSpartan EP 320
AgipBlasia 320

The pump is supplied with the oil already filled; the level is checked through the sight glass and the oil must be changed at least once a year.

Construction

  • Aluminium housing with epoxy coating
  • IP55 protection rating (IP65 optional)
  • PTFE diaphragm

Supplied with

  • Level probe with foot filter
  • Level probe cable
  • Gearbox oil, already filled
  • Blind plug for transport

Pump head materials

Pump head in PVDF

PVDF

Suitable for most acids, for peroxides and for sodium hypochlorite (chlorine).

Pump head in AISI 316L

AISI 316L

Suitable for peracetic acid and sodium hydroxide.

Learn more: chemical compatibility of materials →

Technical support

Troubleshooting and error messages

The most frequent causes of malfunction and the corrective actions to check before contacting technical support.

Learn more: the pump does not prime and does not dose →

If the pump…

Insufficient or no flow rate
  • Air in the pump head or in the suction tubePrime the pump until all the air has been expelled.
  • Suction valve or tube obstructed or not sealingClean or replace the suction valve; replace the tube.
  • Foot filter cloggedClean the filter.
  • Excessive suction lift relative to the tankReduce the suction lift.
  • High-viscosity liquidUse a larger-diameter suction tube.
Overheating of the motor and pump head
  • Insufficient oil levelTop up the oil: the pump must never run without lubricant.
  • Operating pressure above the rated valueInstall a pressure relief valve.
  • Delivery line obstructed or blockedClear the delivery tube.
  • Incorrect electrical connectionsReconnect the pump according to the instructions in the manual.
Liquid leaking from the pump head
  • Ruptured diaphragmContact our technical support service to have the diaphragm replaced.
Display on but showing nothing
  • Display battery flatReplace the 3 V battery located on the circuit board behind the display.

Display of the Prius D MF

MessageMeaningAction
LEVELChemical in the tank has run out.Restore the chemical level in the tank.
OVER FLOWThe required flow rate exceeds the rated value.Check the settings and the flow rate, then switch the pump off and on again.
HIGH VOLTSupply voltage above the permitted limits.Check that the voltage matches the rating plate data; if the pump has locked out, switch it off and on again.
LOW VOLTSupply voltage below the permitted limits; after 5 alarms within two minutes the pump locks out.Check the mains voltage, then switch the pump off and on again.
ANOMALIA IMPIANTOSudden stop of the pump or motor (system fault).Identify and eliminate the cause of the stop, then switch the pump off and on again.

Red display: alarm; yellow: warning; green: normal operation; white: stand-by or OFF. Active alarms can be viewed under SETUP › INFO › ALARMS.

First start-up

Start the pump with the stroke length set to 20% and minimum back pressure; after about 5 minutes increase it gradually. If the pressure exceeds the rated value, stop the motor immediately.

Oil

Check the level using the dedicated indicator and never run the pump without oil; change it every 8,000 – 10,000 operating hours and in any case at least once a year.

Periodic checks

Every three months check bolts and seals; once a year check that flow rate, pressure and power match the rating plate data. With abrasive or corrosive chemicals, shorten the intervals.

If the problem persists, contact us. Before sending the pump for servicing, empty the pump head of chemical and dry it.

Summary

Main features

Electronic flow rate adjustment

According to the operating mode and the set parameters, the pump automatically adapts the injection frequency to ensure the required dosing.

Mechanical flow rate adjustment

The knob reduces the stroke length of the diaphragm, i.e. the volume of each injection and, consequently, the maximum flow rate. This offers two advantages:
Linear dosing: a high number of small-volume injections promotes mixing of the chemical into the water flow and avoids concentration peaks.
Accuracy at low dosing rates: with a 10 l/h pump required to dose 1 l/h, reducing the stroke length to 50% brings the maximum flow rate down to 5 l/h and doubles the injection frequency. Particularly suitable in combination with the pulse-output water meter.

Digital display

The integrated LCD display allows the pump to be programmed and its operating status to be monitored at all times.

Level control

The pump is supplied with a low-level probe for the tank: when the chemical runs out, it shows the alarm on the display and activates the corresponding output.

Stand-by

Pump start and stop can be controlled remotely by means of a run/stop contact from a PLC or another source.

Flow sensor (SEFL version)

A flow sensor can be connected to check every single injection: if one or more injections are missed, the pump performs an automatic re-priming and recovers the lost injections; if this fails, it activates the alarm output.

Alarm output

In the event of a fault, a volt-free contact is activated, configurable as normally open (N.O.) or normally closed (N.C.), to drive a visual or audible signalling device, send an SMS or report the event to a PLC.

Priming button

A dedicated button allows the lines to be filled with the chemical to be dosed.

Versatile mounting

Horizontal installation, or vertical installation by means of a dedicated bracket.

Technical advice

Tell us about your application: our technical staff will recommend the most suitable model, configuration and accessories.

Contact

Tell us about your plant

Call or write to us: a technician will reply with a tailored proposal of controllers, pumps, probes and accessories.

What do you need?
Please enter your name.
Please enter a valid email address.
Please enter your message.

Describe your plant: type, water volume or flow rate, parameters to be controlled.

You must accept the privacy notice to continue.