Technical data
Performance and configurations
The pump code is made up of the model name and the performance: maximum pressure in bar as two digits followed by the flow rate in l/h (Prius D AP MF 5017 = 50 bar, 17 l/h). Performance depends on the working back pressure, the number of strokes per minute and the characteristics of the chemical; with viscous products a lower number of strokes per minute is recommended.
Manual air bleed
Manual air bleed, suitable for most chemicals. LM AP, MM AP, NM AP, SM AP and TM AP high-pressure pump heads.
| Code | Max pressure (bar) | Max flow rate (l/h) | Strokes / minute | Motor (kW) | Pump head | Stroke (mm) |
| Prius D AP MF 10004 | 100 | 4 | 175 | 0.37 | LM AP | 1.5 |
|---|
| Prius D AP MF 10002 | 100 | 2 | 94 | 0.37 | LM AP | 1.5 |
|---|
| Prius D AP MF 1001.5 | 100 | 1.5 | 70 | 0.37 | LM AP | 1.5 |
|---|
| Prius D AP MF 5017 | 50 | 17 | 175 | 0.37 | MM AP | 2 |
|---|
| Prius D AP MF 5009 | 50 | 9 | 94 | 0.37 | MM AP | 2 |
|---|
| Prius D AP MF 5005 | 50 | 5 | 70 | 0.37 | MM AP | 2 |
|---|
| Prius D AP MF 502.5 | 50 | 2.5 | 35 | 0.37 | MM AP | 2 |
|---|
| Prius D AP MF 3028 | 30 | 28 | 175 | 0.37 | NM AP | 2 |
|---|
| Prius D AP MF 3015 | 30 | 15 | 94 | 0.37 | NM AP | 2 |
|---|
| Prius D AP MF 3010 | 30 | 10 | 70 | 0.37 | NM AP | 2 |
|---|
| Prius D AP MF 3005 | 30 | 5 | 35 | 0.37 | NM AP | 2 |
|---|
| Prius D AP MF 3076 | 30 | 76 | 175 | 0.37 | SM AP | 4 |
|---|
| Prius D AP MF 3041 | 30 | 41 | 94 | 0.37 | SM AP | 4 |
|---|
| Prius D AP MF 3030 | 30 | 30 | 70 | 0.37 | SM AP | 4 |
|---|
| Prius D AP MF 3014 | 30 | 14 | 35 | 0.37 | SM AP | 4 |
|---|
| Prius D AP MF 2091 | 20 | 91 | 94 | 0.37 | TM AP | 6 |
|---|
| Prius D AP MF 2068 | 20 | 68 | 70 | 0.37 | TM AP | 6 |
|---|
| Prius D AP MF 2034 | 20 | 34 | 35 | 0.37 | TM AP | 6 |
Technical specifications
| Specification | Value |
| Power supply | Single-phase 230 VAC 50/60 Hz or 115 VAC |
| Ambient temperature | −10 – 40 °C |
| Chemical temperature with PVDF pump head | −10 – 65 °C |
| Chemical temperature with AISI 316L pump head | −10 – 90 °C |
| Noise level | 78 dB(A) ± 5 dB |
| Maximum suction lift | 3 m |
| Gearbox oil | 0.3 l |
| Dosing accuracy | ± 5% at rated pressure |
| Maximum current draw | 2.5 A at 230 VAC; 5 A at 115 VAC (575 VA) |
| Fuse | 6.3 A slow-blow at 230 VAC; 8 A slow-blow at 115 VAC |
| Alarm output | 24 VAC, 1 A contact |
| Motor | Insulation class F, IE1 efficiency |
| Relative humidity | 95%, non-condensing |
| Recommended diaphragm replacement | Every 10,000 operating hours |
The maximum chemical temperatures may be exceeded for a limited time, no longer than 15 minutes, during sterilisation or washing with hot water.
Hydraulic connections
| Pump head | Material | Connection |
| LM AP | AISI 316L | R 3/8″ |
| MM AP | AISI 316L | R 1/2″ |
| NM AP | AISI 316L | R 1/2″ |
| SM AP | AISI 316L | R 1/2″ |
| TM AP | AISI 316L | R 3/4″ |
Pump head material codes
| Code | Pump head |
| K | PVDF |
| S | AISI 316L |
The letter follows the performance in the pump code (PDMF 010060 K…).
Electronics codes
| Code | Electronics |
| MF | Multifunction, 230 VAC power supply |
| M1 | Multifunction, 115 VAC power supply |
| MM | Multifunction with Modbus RTU |
Seal and gearbox codes
| Code | Component | Version |
| V | O-ring | FKM B |
| D | O-ring | EPDM (Dutral) |
| 1 | Reduction ratio | 8:1 |
| 2 | Reduction ratio | 15:1 |
| 3 | Reduction ratio | 10:1 |
| 4 | Reduction ratio | 20:1 |
| 5 | Reduction ratio | 40:1 |
The reduction ratio determines the number of strokes per minute: 8:1 corresponds to 175 strokes, 15:1 to 94, 20:1 to 70 and 40:1 to 35 strokes per minute with a 50 Hz power supply.
Compatible lubricating oils
| Brand | Oil |
| Mobil | Mobilgear 632 |
| Shell | Omala Oil 320 |
| BP | Energol GR-XP 320 |
| IP | Mellana Oil 320 |
| Esso | Spartan EP 320 |
| Agip | Blasia 320 |
The pump is supplied with the oil already filled; the level is checked through the sight glass and the oil must be changed at least once a year.
Construction
- Aluminium housing with epoxy coating
- IP55 protection rating (IP65 optional)
- PTFE diaphragm
Supplied with
- Level probe with foot filter
- Level probe cable
- Gearbox oil, already filled
- Blind plug for transport
Pump head materials
PVDF
Suitable for most acids, for peroxides and for sodium hypochlorite (chlorine).
AISI 316L
Suitable for peracetic acid and sodium hydroxide.
Learn more: chemical compatibility of materials →