Velon CL
For constant dosing, with input for tank level control.
- Constant
Constant peristaltic dosing pump, with the flow rate set by the front potentiometer, an ON/OFF key and a status LED. Tank level control is standard and the alarm output is available as an option. The pump has no digital connections and suits applications that require simple, continuous operation.
For constant dosing, with input for tank level control.
The pump doses at a constant injection frequency, proportional to the flow rate percentage set with the analogue selector (0 – 100%).
Peristaltic pumps deliver the product continuously; the electronically controlled stepper motor optimises dosing, which is continuous and free of pulsations. The flow rate is adjusted by frequency, by varying the number of revolutions per minute of the motor.
The stepper motor and the control software deliver the product optimally with completely silent operation, a feature appreciated when dosing aromatic essences in saunas and Turkish baths, or pH adjuster and disinfectant in swimming pools and hot tubs.

The tube is made of TPV, an elastomer compatible with most chemicals, which retains its elastic properties even after millions of compression cycles by the rollers. The Velon is also suitable for dosing products that release gas, such as hydrogen peroxide or peracetic acid.
Performance depends on the diameter of the peristaltic tube and on the rotation speed of the motor, adjustable from 1 to 100 revolutions per minute, as well as on the characteristics of the chemical.
Suitable for dosing most chemicals.
| Tube (mm) | Max pressure (bar) | Max flow rate (l/h) | ml/rev | RPM | Flow rate range (l/h) |
|---|---|---|---|---|---|
| 1.6 × 1.6 | 2 | 1.8 | 0.3 | 1 – 100 | 0.018 – 1.8 |
| 1.6 × 4.8 | 2 | 12 | 2 | 1 – 100 | 0.12 – 12 |
| Specification | Value |
|---|---|
| User interface | Potentiometer, ON/OFF key and status LED |
| Inputs | Level |
| Outputs | Alarm (optional) |
| Connectivity | None |
| Power supply | 100 – 240 VAC, 12 VDC or 24 VDC |
| Maximum pressure | 2 bar |
| Rotor speed | 1 – 100 rpm |
| Maximum chemical viscosity | 100 cP |
| Ambient temperature | 10 – 45 °C |
| Chemical temperature | 0 – 50 °C |
| Transport and storage temperature | −10 – 50 °C |
| Relative humidity | 85% up to 40 °C; 70% at 50 °C |
| Protection rating | IP65 |
| Installation category | II |
| Pollution degree | 2 |
| Component | Material |
|---|---|
| Pump body | PC/ABS |
| Cover | PC |
| Dust bushing | PEEK/PPS |
| Tube retainer, tube and vent hose connectors | PVDF |
| Rollers | POM (Delrin) |
| Long-life peristaltic tube | TPV |
The most frequent causes of malfunction and the corrective actions to check before contacting technical support.
Learn more: the pump does not prime and does not dose →| LED | Meaning | Action |
|---|---|---|
| Steady red | Level alarm. | Refill the tank. |
| Flashing red | Motor alarm or bus communication error. | Contact us. |
| Green, goes off at every revolution | Running, dosing (clockwise rotation). | No action required. |
| Green, fast flashing | Paused (OFF), powered. | No action required. |
| Orange, goes off at every revolution | Running in reverse (emptying, anticlockwise rotation). | No action required. |
| Orange, fast flashing | Paused (OFF), in emptying mode. | No action required. |
Velon CL: hold down the ON/OFF key for 2 seconds to stop the pump; with the pump stopped, hold it down for 4 seconds to switch from dosing to emptying and vice versa.
Switch off and disconnect the pump, close the valves and drain the liquid. Open the cover, remove the rotor cover disc and take out the slide with the worn tube; insert the new slide and bring the tube into position by turning the roller holder. Check by hand that it rotates freely, reassemble and carry out a dry test. If the roller holder is removed, the letter “A” must face the operator.
The TEST function runs the pump for the set time (1 – 60 minutes): measuring the chemical drawn in makes it possible to determine the actual flow rate under the installation conditions.
If the problem persists, contact us. Before sending the pump for servicing, empty the pump head of chemical and dry it.
According to the operating mode and the set parameters, the pump automatically adapts the injection frequency to ensure the required dosing.
The pump is supplied with a low-level probe for the tank: when the chemical runs out, it shows the alarm on the display and activates the corresponding output.
On request, in the event of a fault a volt-free contact is activated, configurable as normally open (N.O.) or normally closed (N.C.), to drive a visual or audible signalling device, send an SMS or report the event to a PLC.
A dedicated button allows the lines to be filled with the chemical to be dosed.
Vertical installation, or horizontal installation by means of a dedicated bracket.
Tell us about your application: our technical staff will recommend the most suitable model, configuration and accessories.
Call or write to us: a technician will reply with a tailored proposal of controllers, pumps, probes and accessories.