RACP
Compressed air dosing pump with button for manual priming.
- Constant
- Pneumatic adjustment
Compressed-air operated diaphragm dosing pump, suitable for car wash installations, with a front button for manual priming: the pump head fills with chemical before start-up, without contact with the chemical. The pump needs no electrical supply and the flow rate is adjusted with the piston stroke knob.
Compressed air dosing pump with button for manual priming.
Pump head: PP
Power supply: compressed air from 6 to 8 bar
The pump doses at a constant injection frequency, proportional to the flow rate percentage set with the analogue selector (0 – 100%).
The front knob adjusts the piston stroke, that is the volume of each injection; the frequency, up to 120 injections per minute, is given by the compressed air pulsed by the solenoid valve: each cycle lasts approximately 0.5 seconds, half with the pump supplied with air and half without supply.
The pump code is made up of the model name and the performance: maximum pressure in bar as two digits followed by the flow rate in l/h (RACP 0606 = 6 bar, 6 l/h). It is followed by the pump head code, listed in the table at the end of this section. Performance varies with the working back pressure and with the characteristics of the chemical.
Suitable for most chemicals: the standard configuration for the most common applications.
| Code | Max pressure (bar) | Max flow rate (l/h) | Tubing (mm) |
|---|---|---|---|
| RACP 0612 | 6 | 12 | 4 x 6 or 6 x 8 |
| RACP 0606 | 6 | 6 | 4 x 6 or 6 x 8 |
| RACP 0603 | 6 | 3 | 4 x 6 or 6 x 8 |
| RACP 0601 | 6 | 1 | 4 x 6 or 6 x 8 |
1/2” valves in all configurations.
| Specification | Value |
|---|---|
| Strokes per minute | 12 – 120 |
| Compressed air supply | 6 – 8 bar, air free of lubricant and condensate |
| Air consumption | 2.4 l/min |
| Air per injection | 0.020 l |
| Air tube connection | 6 x 8 |
| Maximum chemical viscosity | 100 cP |
| Ambient temperature | −10 – 50 °C |
| Flow rate adjustment | Piston stroke knob |
| Valves | Double ball, 6 mm ceramic or stainless steel balls |
| Diaphragm | PTFE |
| Housing | Glass-filled PP |
| Mounting | Horizontal on a bracket, wall or DIN rail, also side by side |
| Code | Pump head | Seals | Valves | Balls |
|---|---|---|---|---|
| V | PP | FKM | PP | Stainless steel |
| D | PP | EPDM | PP | Stainless steel |
| W | PP | NBR | PP | Stainless steel |
PTFE diaphragm, PE delivery tube and PVC suction tube.
Suitable for sodium hydroxide (caustic soda).
The R Series pumps have no electronics: most faults can be traced back to the compressed air supply or to maintenance.
Learn more: the pump does not prime and does not dose →R pumps require a constant air supply, preferably at 6 bar (± 10%), free of oil and condensate. The maximum frequency is 120 injections per minute (approximately 0.25 s of work and 0.25 s of return): the solenoid valve or PLC must be set accordingly.
Connect discharge, suction and drain, open the drain valve, set the knob to 100% and supply air; close the drain as soon as the chemical comes out. On the RACP the operation can be assisted with the manual priming button; with viscous chemicals use a 20 cc syringe applied to the drain.
At least once a month check the electrical and hydraulic connections, the condition of the diaphragm, the absence of leaks from tubes and fittings and any corroded parts.
If the problem persists, contact us. Before sending the pump for servicing, empty the pump head of chemical and dry it.
The knob reduces the stroke length of the piston, i.e. the volume of each injection and, consequently, the maximum flow rate. This offers two advantages:
Linear dosing: a high number of small-volume injections promotes mixing of the chemical into the water flow and avoids concentration peaks.
Accuracy at low dosing rates: with a 10 l/h pump required to dose 1 l/h, reducing the stroke length to 50% brings the maximum flow rate down to 5 l/h and doubles the injection frequency. Particularly suitable in combination with the pulse-output water meter.
A dedicated button allows the lines to be filled with the chemical to be dosed.
Horizontal installation, on a DIN rail, or vertical installation by means of a dedicated bracket.
Tell us about your application: our technical staff will recommend the most suitable model, configuration and accessories.
Call or write to us: a technician will reply with a tailored proposal of controllers, pumps, probes and accessories.