Compressed air dosing pump

RACP

Compressed-air operated diaphragm dosing pump, suitable for car wash installations, with a front button for manual priming: the pump head fills with chemical before start-up, without contact with the chemical. The pump needs no electrical supply and the flow rate is adjusted with the piston stroke knob.

  • Priming button
  • No electrical supply
  • Compressed air from 6 to 8 bar
  • Up to 12 l/h
RACP dosing pump
12l/hMaximum flow rate
6barMaximum pressure
4Configurations
120/minMaximum strokes
The model

RACP

RACP dosing pump
With priming button

RACP

Compressed air dosing pump with button for manual priming.

  • Constant
  • Pneumatic adjustment

Pump head: PP

Power supply: compressed air from 6 to 8 bar

Operation

Dosing modes

Constant

The pump doses at a constant injection frequency, proportional to the flow rate percentage set with the analogue selector (0 – 100%).

Pneumatic adjustment

The front knob adjusts the piston stroke, that is the volume of each injection; the frequency, up to 120 injections per minute, is given by the compressed air pulsed by the solenoid valve: each cycle lasts approximately 0.5 seconds, half with the pump supplied with air and half without supply.

Technical data

Performance and configurations

The pump code is made up of the model name and the performance: maximum pressure in bar as two digits followed by the flow rate in l/h (RACP 0606 = 6 bar, 6 l/h). It is followed by the pump head code, listed in the table at the end of this section. Performance varies with the working back pressure and with the characteristics of the chemical.

Manual air bleed

Suitable for most chemicals: the standard configuration for the most common applications.

CodeMax pressure (bar)Max flow rate (l/h)Tubing (mm)
RACP 06126124 x 6 or 6 x 8
RACP 0606664 x 6 or 6 x 8
RACP 0603634 x 6 or 6 x 8
RACP 0601614 x 6 or 6 x 8

1/2” valves in all configurations.

Technical specifications

SpecificationValue
Strokes per minute12 – 120
Compressed air supply6 – 8 bar, air free of lubricant and condensate
Air consumption2.4 l/min
Air per injection0.020 l
Air tube connection6 x 8
Maximum chemical viscosity100 cP
Ambient temperature−10 – 50 °C
Flow rate adjustmentPiston stroke knob
ValvesDouble ball, 6 mm ceramic or stainless steel balls
DiaphragmPTFE
HousingGlass-filled PP
MountingHorizontal on a bracket, wall or DIN rail, also side by side

Pump head codes

CodePump headSealsValvesBalls
VPPFKMPPStainless steel
DPPEPDMPPStainless steel
WPPNBRPPStainless steel

PTFE diaphragm, PE delivery tube and PVC suction tube.

Power supplies

  • Compressed air from 6 to 8 bar, no electrical supply

Supplied with

  • 1/2” foot filter with valve
  • 1/2” injection valve
  • Delivery, suction and drain tubes (2 m each)
  • Operating manual

Pump head materials

Pump head in PP

PP

Suitable for sodium hydroxide (caustic soda).

Learn more: chemical compatibility of materials →

Technical support

Troubleshooting and error messages

The R Series pumps have no electronics: most faults can be traced back to the compressed air supply or to maintenance.

Learn more: the pump does not prime and does not dose →

Compressed air

R pumps require a constant air supply, preferably at 6 bar (± 10%), free of oil and condensate. The maximum frequency is 120 injections per minute (approximately 0.25 s of work and 0.25 s of return): the solenoid valve or PLC must be set accordingly.

Priming

Connect discharge, suction and drain, open the drain valve, set the knob to 100% and supply air; close the drain as soon as the chemical comes out. On the RACP the operation can be assisted with the manual priming button; with viscous chemicals use a 20 cc syringe applied to the drain.

Monthly check

At least once a month check the electrical and hydraulic connections, the condition of the diaphragm, the absence of leaks from tubes and fittings and any corroded parts.

If the problem persists, contact us. Before sending the pump for servicing, empty the pump head of chemical and dry it.

Summary

Main features

Mechanical flow rate adjustment

The knob reduces the stroke length of the piston, i.e. the volume of each injection and, consequently, the maximum flow rate. This offers two advantages:
Linear dosing: a high number of small-volume injections promotes mixing of the chemical into the water flow and avoids concentration peaks.
Accuracy at low dosing rates: with a 10 l/h pump required to dose 1 l/h, reducing the stroke length to 50% brings the maximum flow rate down to 5 l/h and doubles the injection frequency. Particularly suitable in combination with the pulse-output water meter.

Priming button

A dedicated button allows the lines to be filled with the chemical to be dosed.

Versatile mounting

Horizontal installation, on a DIN rail, or vertical installation by means of a dedicated bracket.

Technical advice

Tell us about your application: our technical staff will recommend the most suitable model, configuration and accessories.

Contact

Tell us about your plant

Call or write to us: a technician will reply with a tailored proposal of controllers, pumps, probes and accessories.

What do you need?
Please enter your name.
Please enter a valid email address.
Please enter your message.

Describe your plant: type, water volume or flow rate, parameters to be controlled.

You must accept the privacy notice to continue.