Prius P
For constant dosing of chemicals.
- Constant
Motor-driven piston dosing pump for constant dosing of chemicals in industrial plants, with a three-phase motor. The flow rate is adjusted with the stroke length knob, which varies the volume of each injection. The piston is made of ceramic with a PP pump head, or of stainless steel with an AISI 316L pump head; with the 63 mm stainless steel piston the flow rate reaches 508 l/h.
For constant dosing of chemicals.
Pump head: PP with ceramic piston, or AISI 316L with AISI 420 piston
Power supply: three-phase 220-240 / 380-420 V 50 Hz or 220 / 380 V 60 Hz
The pump doses at a constant frequency, according to the flow rate percentage set with the knob that adjusts the stroke length of the piston.
The pump code is made up of the model name and the performance: maximum pressure in bar as two digits followed by the flow rate in l/h (Prius P 1024 = 10 bar, 24 l/h). The flow rate depends on the piston diameter and on the number of strokes per minute; with viscous products a lower number of strokes per minute is recommended.
Manual air bleed, suitable for most chemicals. Pistons from 14 to 50 mm, ceramic with a PP pump head or stainless steel with an AISI 316L pump head.
| Code | Max pressure (bar) | Max flow rate (l/h) | Strokes / minute | Motor (kW) | Piston diameter (mm) |
|---|---|---|---|---|---|
| Prius P 1024 | 10 | 24 | 175 | 0.18 | 14 |
| Prius P 1013 | 10 | 13 | 94 | 0.18 | 14 |
| Prius P 1010 | 10 | 10 | 70 | 0.18 | 14 |
| Prius P 1005 | 10 | 5 | 35 | 0.18 | 14 |
| Prius P 1080 | 10 | 80 | 175 | 0.18 | 25 |
| Prius P 1043 | 10 | 43 | 94 | 0.18 | 25 |
| Prius P 1032 | 10 | 32 | 70 | 0.18 | 25 |
| Prius P 1016 | 10 | 16 | 35 | 0.18 | 25 |
| Prius P 10130 | 10 | 130 | 175 | 0.18 | 32 |
| Prius P 1070 | 10 | 70 | 94 | 0.18 | 32 |
| Prius P 1052 | 10 | 52 | 70 | 0.18 | 32 |
| Prius P 1026 | 10 | 26 | 35 | 0.18 | 32 |
| Prius P 10210 | 10 | 210 | 175 | 0.37 | 40 |
| Prius P 10113 | 10 | 113 | 94 | 0.37 | 40 |
| Prius P 1084 | 10 | 84 | 70 | 0.37 | 40 |
| Prius P 1042 | 10 | 42 | 35 | 0.37 | 40 |
| Prius P 10320 | 10 | 320 | 175 | 0.37 | 50 |
| Prius P 10172 | 10 | 172 | 94 | 0.37 | 50 |
| Prius P 10128 | 10 | 128 | 70 | 0.37 | 50 |
| Prius P 1064 | 10 | 64 | 35 | 0.37 | 50 |
| Prius P 07508 | 7 | 508 | 175 | 0.55 | 63 |
| Prius P 07273 | 7 | 273 | 94 | 0.37 | 63 |
| Prius P 07203 | 7 | 203 | 70 | 0.37 | 63 |
| Prius P 07101 | 7 | 101 | 35 | 0.37 | 63 |
The 7 bar configurations, with a 63 mm piston, are available only with stainless steel pump head and piston. Motor ratings refer to three-phase 50 Hz motors.
| Specification | Value |
|---|---|
| Power supply | Three-phase 220-240 / 380-420 V 50 Hz or 220 / 380 V 60 Hz |
| Ambient temperature | −10 – 40 °C |
| Chemical temperature with PP pump head | −10 – 40 °C |
| Chemical temperature with stainless steel pump head | −10 – 90 °C |
| Piston stroke | 15 mm |
| Piston | SIALOX 96 ceramic with PP pump head; AISI 420 stainless steel with AISI 316L pump head |
| Dosing accuracy | ± 5% at rated pressure |
| Noise level | 78 dB(A) ± 5 dB |
| Maximum suction lift | 3 m |
| Gearbox oil | 0.3 l |
| Motor | Insulation class F, IE1 efficiency |
| Three-phase 50 Hz motors | 0.18 kW at 1,350 rpm; 0.37 kW at 1,370 rpm; 0.55 kW for the 508 l/h configuration |
The maximum chemical temperature with the stainless steel pump head may be exceeded for a limited time, no longer than 15 minutes, during sterilisation or washing with hot water.
| Piston diameter | PP with ceramic piston | AISI 316L with AISI 420 piston |
|---|---|---|
| 14, 25 and 32 mm | G 1/2″, 12 × 18 tube | R 1/2″ |
| 40 and 50 mm | G 3/4″, 18 mm i.d. tube | R 3/4″ |
| 63 mm | Not available | R 1″ |
Installation kit A is included in the supply with a PP pump head and pistons from 14 to 32 mm: 1/2″ foot filter with 13 mm i.d. hose connector, 3/4″ injection valve and delivery and suction tubes, 13 × 16 PVDF or 12 × 18 PVC. Optional kits are kit B, for the 40 and 50 mm pistons, with 1 1/2″ foot filter with 18 mm i.d. hose connector and 1 1/2″ injection valve, and kit C, with 1 1/2″ foot filter with 32 mm i.d. hose connector and 1 1/2″ injection valve. No installation accessories are provided with the stainless steel pump head.
| Code | Component | Version |
|---|---|---|
| 1 | Motor and power supply | 0.18 kW, three-phase 220-240 / 380-420 V 50 Hz |
| 2 | Motor and power supply | 0.37 kW, three-phase 220-240 / 380-420 V 50 Hz |
| 3 | Motor and power supply | 0.18 kW, three-phase 220 / 380 V 60 Hz |
| 4 | Motor and power supply | 0.37 kW, three-phase 220 / 380 V 60 Hz |
| D | Pump head and piston | PP with SIALOX 96 ceramic piston |
| E | Pump head and piston | AISI 316L with AISI 420 piston |
| V | O-ring | FKM B |
| D | O-ring | EPDM (Dutral) |
| W | O-ring | WAX |
| 1 | Reduction ratio | 8:1 |
| 2 | Reduction ratio | 15:1 |
| 4 | Reduction ratio | 20:1 |
| Brand | Oil |
|---|---|
| Mobil | Mobilgear 632 |
| Shell | Omala Oil 320 |
| BP | Energol GR-XP 320 |
| IP | Mellana Oil 320 |
| Esso | Spartan EP 320 |
| Agip | Blasia 320 |
The pump is supplied with the oil already filled; the level is checked through the sight glass and the oil must be changed at least once a year.
PP pump head and SIALOX96 ceramic piston.
AISI 316L stainless steel pump head and AISI 420 stainless steel piston.
The most frequent causes of malfunction and the corrective actions to check before contacting technical support.
Learn more: the pump does not prime and does not dose →Start the pump with the stroke length set to 20% and minimum back pressure; after about 5 minutes increase it gradually. If the pressure exceeds the rated value, stop the motor immediately.
Check the level using the dedicated indicator and never run the pump without oil; change it every 8,000 – 10,000 operating hours and in any case at least once a year.
Every three months check bolts and seals; once a year check that flow rate, pressure and power match the rating plate data. With abrasive or corrosive chemicals, shorten the intervals.
If the problem persists, contact us. Before sending the pump for servicing, empty the pump head of chemical and dry it.
The knob reduces the stroke length of the piston, i.e. the volume of each injection and, consequently, the maximum flow rate. This offers two advantages:
Linear dosing: a high number of small-volume injections promotes mixing of the chemical into the water flow and avoids concentration peaks.
Accuracy at low dosing rates: with a 10 l/h pump required to dose 1 l/h, reducing the stroke length to 50% brings the maximum flow rate down to 5 l/h and doubles the injection frequency. Particularly suitable in combination with the pulse-output water meter.
Horizontal installation, or vertical installation by means of a dedicated bracket.
Tell us about your application: our technical staff will recommend the most suitable model, configuration and accessories.
Call or write to us: a technician will reply with a tailored proposal of controllers, pumps, probes and accessories.