Skip to content
Motor-driven piston dosing pump

Prius P

Motor-driven piston dosing pump for constant dosing of chemicals in industrial plants, with a three-phase motor. The flow rate is adjusted with the stroke length knob, which varies the volume of each injection. The piston is made of ceramic with a PP pump head, or of stainless steel with an AISI 316L pump head; with the 63 mm stainless steel piston the flow rate reaches 508 l/h.

  • Up to 508 l/h
  • Up to 10 bar
  • Three-phase motor
  • Pistons from 14 to 63 mm
Prius P dosing pump
508l/hMaximum flow rate
10barMaximum pressure
24Configurations
IP55Protection rating
The model

Prius P

Prius P dosing pump
Constant dosing

Prius P

For constant dosing of chemicals.

  • Constant

Pump head: PP with ceramic piston, or AISI 316L with AISI 420 piston

Power supply: three-phase 220-240 / 380-420 V 50 Hz or 220 / 380 V 60 Hz

Operation

Dosing modes

Constant

The pump doses at a constant frequency, according to the flow rate percentage set with the knob that adjusts the stroke length of the piston.

Technical data

Performance and configurations

The pump code is made up of the model name and the performance: maximum pressure in bar as two digits followed by the flow rate in l/h (Prius P 1024 = 10 bar, 24 l/h). The flow rate depends on the piston diameter and on the number of strokes per minute; with viscous products a lower number of strokes per minute is recommended.

Manual air bleed

Manual air bleed, suitable for most chemicals. Pistons from 14 to 50 mm, ceramic with a PP pump head or stainless steel with an AISI 316L pump head.

CodeMax pressure (bar)Max flow rate (l/h)Strokes / minuteMotor (kW)Piston diameter (mm)
Prius P 102410241750.1814
Prius P 10131013940.1814
Prius P 10101010700.1814
Prius P 1005105350.1814
Prius P 108010801750.1825
Prius P 10431043940.1825
Prius P 10321032700.1825
Prius P 10161016350.1825
Prius P 10130101301750.1832
Prius P 10701070940.1832
Prius P 10521052700.1832
Prius P 10261026350.1832
Prius P 10210102101750.3740
Prius P 1011310113940.3740
Prius P 10841084700.3740
Prius P 10421042350.3740
Prius P 10320103201750.3750
Prius P 1017210172940.3750
Prius P 1012810128700.3750
Prius P 10641064350.3750
Prius P 0750875081750.5563
Prius P 072737273940.3763
Prius P 072037203700.3763
Prius P 071017101350.3763

The 7 bar configurations, with a 63 mm piston, are available only with stainless steel pump head and piston. Motor ratings refer to three-phase 50 Hz motors.

Technical specifications

SpecificationValue
Power supplyThree-phase 220-240 / 380-420 V 50 Hz or 220 / 380 V 60 Hz
Ambient temperature−10 – 40 °C
Chemical temperature with PP pump head−10 – 40 °C
Chemical temperature with stainless steel pump head−10 – 90 °C
Piston stroke15 mm
PistonSIALOX 96 ceramic with PP pump head; AISI 420 stainless steel with AISI 316L pump head
Dosing accuracy± 5% at rated pressure
Noise level78 dB(A) ± 5 dB
Maximum suction lift3 m
Gearbox oil0.3 l
MotorInsulation class F, IE1 efficiency
Three-phase 50 Hz motors0.18 kW at 1,350 rpm; 0.37 kW at 1,370 rpm; 0.55 kW for the 508 l/h configuration

The maximum chemical temperature with the stainless steel pump head may be exceeded for a limited time, no longer than 15 minutes, during sterilisation or washing with hot water.

Hydraulic connections

Piston diameterPP with ceramic pistonAISI 316L with AISI 420 piston
14, 25 and 32 mmG 1/2″, 12 × 18 tubeR 1/2″
40 and 50 mmG 3/4″, 18 mm i.d. tubeR 3/4″
63 mmNot availableR 1″

Installation kit A is included in the supply with a PP pump head and pistons from 14 to 32 mm: 1/2″ foot filter with 13 mm i.d. hose connector, 3/4″ injection valve and delivery and suction tubes, 13 × 16 PVDF or 12 × 18 PVC. Optional kits are kit B, for the 40 and 50 mm pistons, with 1 1/2″ foot filter with 18 mm i.d. hose connector and 1 1/2″ injection valve, and kit C, with 1 1/2″ foot filter with 32 mm i.d. hose connector and 1 1/2″ injection valve. No installation accessories are provided with the stainless steel pump head.

Pump codes

CodeComponentVersion
1Motor and power supply0.18 kW, three-phase 220-240 / 380-420 V 50 Hz
2Motor and power supply0.37 kW, three-phase 220-240 / 380-420 V 50 Hz
3Motor and power supply0.18 kW, three-phase 220 / 380 V 60 Hz
4Motor and power supply0.37 kW, three-phase 220 / 380 V 60 Hz
DPump head and pistonPP with SIALOX 96 ceramic piston
EPump head and pistonAISI 316L with AISI 420 piston
VO-ringFKM B
DO-ringEPDM (Dutral)
WO-ringWAX
1Reduction ratio8:1
2Reduction ratio15:1
4Reduction ratio20:1

Compatible lubricating oils

BrandOil
MobilMobilgear 632
ShellOmala Oil 320
BPEnergol GR-XP 320
IPMellana Oil 320
EssoSpartan EP 320
AgipBlasia 320

The pump is supplied with the oil already filled; the level is checked through the sight glass and the oil must be changed at least once a year.

Construction

  • Aluminium housing with epoxy coating
  • IP55 protection rating (IP65 optional)

Supplied with

  • Gearbox oil, already filled
  • Installation kit A with PP pump head and pistons from 14 to 32 mm

Wetted parts

PP pump head and SIALOX96 ceramic piston

PP + ceramic

PP pump head and SIALOX96 ceramic piston.

AISI 316L stainless steel pump head and AISI 420 stainless steel piston

AISI 316L + AISI 420

AISI 316L stainless steel pump head and AISI 420 stainless steel piston.

Learn more: chemical compatibility of materials →

Technical support

Troubleshooting and error messages

The most frequent causes of malfunction and the corrective actions to check before contacting technical support.

Learn more: the pump does not prime and does not dose →

If the pump…

Insufficient or no flow rate
  • Air in the pump head or in the suction tubePrime the pump until all the air has been expelled.
  • Suction valve or tube obstructed or not sealingClean or replace the suction valve; replace the tube.
  • Foot filter cloggedClean the filter.
  • Excessive suction lift relative to the tankReduce the suction lift.
  • High-viscosity liquidUse a larger-diameter suction tube.
Overheating of the motor and pump head
  • Insufficient oil levelTop up the oil: the pump must never run without lubricant.
  • Operating pressure above the rated valueInstall a pressure relief valve.
  • Delivery line obstructed or blockedClear the delivery tube.
  • Incorrect electrical connectionsReconnect the pump according to the instructions in the manual.
Liquid leaking from the pump head
  • Damaged piston O-ringContact our technical support service for replacement.

First start-up

Start the pump with the stroke length set to 20% and minimum back pressure; after about 5 minutes increase it gradually. If the pressure exceeds the rated value, stop the motor immediately.

Oil

Check the level using the dedicated indicator and never run the pump without oil; change it every 8,000 – 10,000 operating hours and in any case at least once a year.

Periodic checks

Every three months check bolts and seals; once a year check that flow rate, pressure and power match the rating plate data. With abrasive or corrosive chemicals, shorten the intervals.

If the problem persists, contact us. Before sending the pump for servicing, empty the pump head of chemical and dry it.

Summary

Main features

Mechanical flow rate adjustment

The knob reduces the stroke length of the piston, i.e. the volume of each injection and, consequently, the maximum flow rate. This offers two advantages:
Linear dosing: a high number of small-volume injections promotes mixing of the chemical into the water flow and avoids concentration peaks.
Accuracy at low dosing rates: with a 10 l/h pump required to dose 1 l/h, reducing the stroke length to 50% brings the maximum flow rate down to 5 l/h and doubles the injection frequency. Particularly suitable in combination with the pulse-output water meter.

Versatile mounting

Horizontal installation, or vertical installation by means of a dedicated bracket.

Technical advice

Tell us about your application: our technical staff will recommend the most suitable model, configuration and accessories.

Contact

Tell us about your plant

Call or write to us: a technician will reply with a tailored proposal of controllers, pumps, probes and accessories.

What do you need?
Please enter your name.
Please enter a valid email address.
Please enter your message.

Describe your plant: type, water volume or flow rate, parameters to be controlled.

You must accept the privacy notice to continue.