Prius D
For constant dosing of chemicals.
- Constant
Motor-driven dosing pump with PTFE diaphragm for constant dosing of chemicals in industrial plants. The flow rate is adjusted between 0 and 100% with the knob that varies the stroke length and therefore the volume of each injection. It is available with a three-phase or single-phase motor and also in an ATEX-certified version for potentially explosive atmospheres.
For constant dosing of chemicals.
Pump head: PVDF, PP, PMMA or AISI 316L
Power supply: three-phase 220-240 / 380-420 V 50 Hz, 220 / 380 V or 440 / 480 V 60 Hz; single-phase 220-240 V 50 Hz or 230 V 60 Hz
The pump doses at a constant frequency, according to the flow rate percentage set with the knob that adjusts the stroke length of the diaphragm.
The pump code is made up of the model name and the performance: maximum pressure in bar as two digits followed by the flow rate in l/h (Prius D 1060 = 10 bar, 60 l/h). Performance depends on the working back pressure, the number of strokes per minute and the characteristics of the chemical; with viscous products a lower number of strokes per minute is recommended.
Manual air bleed, suitable for most chemicals. NM, TM and UMS pump heads in PVDF, PP or AISI 316L stainless steel.
| Code | Max pressure (bar) | Max flow rate (l/h) | Strokes / minute | Motor (kW) | Pump head | Stroke (mm) |
|---|---|---|---|---|---|---|
| Prius D 1060 | 10 | 60 | 175 | 0.18 | NM | 3 |
| Prius D 1030 | 10 | 30 | 94 | 0.18 | NM | 3 |
| Prius D 1024 | 10 | 24 | 70 | 0.18 | NM | 3 |
| Prius D 1012 | 10 | 12 | 35 | 0.18 | NM | 3 |
| Prius D 1016 | 10 | 16 | 35 | 0.18 | NM | 4 |
| Prius D 10105 | 10 | 105 | 175 | 0.37 | TM | 3 |
| Prius D 1056 | 10 | 56 | 94 | 0.37 | TM | 3 |
| Prius D 1042 | 10 | 42 | 70 | 0.37 | TM | 3 |
| Prius D 1021 | 10 | 21 | 35 | 0.37 | TM | 3 |
| Prius D 07160 | 7 | 160 | 175 | 0.37 | TM | 4 |
| Prius D 0786 | 7 | 86 | 94 | 0.37 | TM | 4 |
| Prius D 0764 | 7 | 64 | 70 | 0.37 | TM | 4 |
| Prius D 0732 | 7 | 32 | 35 | 0.37 | TM | 4 |
| Prius D 05240 | 5 | 240 | 175 | 0.37 | TM | 6 |
| Prius D 05128 | 5 | 128 | 94 | 0.37 | TM | 6 |
| Prius D 0596 | 5 | 96 | 70 | 0.37 | TM | 6 |
| Prius D 0548 | 5 | 48 | 35 | 0.37 | TM | 6 |
| Prius D 021000 | 2 | 1,000 | 175 | 0.37 | UMS | 10 |
| Prius D 051000 | 5 | 1,000 | 175 | 0.55 | UMS | 10 |
| Prius D 05520 | 5 | 520 | 94 | 0.37 | UMS | 10 |
| Prius D 04520 | 4 | 520 | 94 | 0.37 | UMS | 10 |
| Prius D 05390 | 5 | 390 | 70 | 0.37 | UMS | 10 |
| Prius D 05180 | 5 | 180 | 35 | 0.37 | UMS | 10 |
| Prius D 05350 | 5 | 350 | 175 | 0.37 | UMS | 4 |
| Prius D 05188 | 5 | 188 | 94 | 0.37 | UMS | 4 |
| Prius D 05140 | 5 | 140 | 70 | 0.37 | UMS | 4 |
| Prius D 0570 | 5 | 70 | 35 | 0.37 | UMS | 4 |
| Prius D 05440 | 5 | 440 | 175 | 0.37 | UMS | 5 |
| Prius D 05236 | 5 | 236 | 94 | 0.37 | UMS | 5 |
| Prius D 05176 | 5 | 176 | 70 | 0.37 | UMS | 5 |
| Prius D 0588 | 5 | 88 | 35 | 0.37 | UMS | 5 |
| Prius D 05530 | 5 | 530 | 175 | 0.37 | UMS | 6 |
| Prius D 05284 | 5 | 284 | 94 | 0.37 | UMS | 6 |
| Prius D 05212 | 5 | 212 | 70 | 0.37 | UMS | 6 |
| Prius D 05106 | 5 | 106 | 35 | 0.37 | UMS | 6 |
| Prius D 03750 | 3 | 750 | 175 | 0.37 | UMS | 8 |
| Prius D 05750 | 5 | 750 | 175 | 0.55 | UMS | 8 |
| Prius D 05380 | 5 | 380 | 94 | 0.37 | UMS | 8 |
| Prius D 05290 | 5 | 290 | 70 | 0.37 | UMS | 8 |
| Prius D 05141 | 5 | 141 | 35 | 0.37 | UMS | 8 |
Motor ratings refer to three-phase 50 Hz motors; with a single-phase motor some models are fitted with a motor of different power.
| Specification | Value |
|---|---|
| Power supply | Three-phase 220-240 / 380-420 V 50 Hz, 220 / 380 V or 440 / 480 V 60 Hz; single-phase 220-240 V 50 Hz or 230 V 60 Hz |
| Ambient temperature | −10 – 40 °C |
| Chemical temperature with PVDF pump head | −10 – 65 °C |
| Chemical temperature with PP pump head | −10 – 40 °C |
| Chemical temperature with AISI 316L pump head | −10 – 90 °C |
| Noise level | 78 dB(A) ± 5 dB |
| Maximum suction lift | 3 m |
| Gearbox oil | 0.3 l |
| Maximum viscosity | Up to 50,000 cP, depending on the pump head |
| Three-phase motors | 0.18 kW, 0.37 kW or 0.55 kW |
| Single-phase motors | 0.37 kW or 0.55 kW |
The maximum chemical temperatures may be exceeded for a limited time, no longer than 15 minutes, during sterilisation or washing with hot water.
| Pump head | PVDF and PP | AISI 316L |
|---|---|---|
| NM | G 1/2″, 13 mm i.d. tube | R 1/2″ |
| TM, 3 – 4 mm stroke | G 3/4″, 13 mm i.d. tube | R 3/4″ |
| TM, 6 mm stroke | G 3/4″, 18 mm i.d. tube | R 3/4″ |
| UMS | G 1 1/2″, 30 mm i.d. tube | R 1″ |
Installation kits: kit A, for NM and TM pump heads with a stroke up to 4 mm, is included in the supply; kits B, for the TM with a 6 mm stroke, and C, for the UMS, are sold separately. No installation accessories are provided with the AISI 316L pump head.
| Category | Marking | Construction |
|---|---|---|
| Category 2, gas (zone 1) | II 2G Ex h IIC T3 Gb | AISI 316L, NM and TM pump heads |
| Category 2, dust (zone 21) | II 2D Ex h IIIC T120 °C Db | AISI 316L, NM and TM pump heads |
| Category 3, gas (zone 2) | II 3G Ex h IIC T3 Gc | PVDF, PP or AISI 316L |
| Category 3, dust (zone 22) | II 3D Ex h IIIC T120 °C Dc | PVDF, PP or AISI 316L |
The ATEX versions are designed in accordance with Directive 2014/34/EU and can be used in zones classified according to Directive 1999/92/EC. Their performance and motor ratings differ in part from those listed above and are provided on request.
| Brand | Oil |
|---|---|
| Mobil | Mobilgear 632 |
| Shell | Omala Oil 320 |
| BP | Energol GR-XP 320 |
| IP | Mellana Oil 320 |
| Esso | Spartan EP 320 |
| Agip | Blasia 320 |
The pump is supplied with the oil already filled; the level is checked through the sight glass and the oil must be changed at least once a year.
Suitable for most acids, for peroxides and for sodium hypochlorite (chlorine).
Suitable for sodium hydroxide (caustic soda).
Suitable for peracetic acid and sodium hydroxide.
Suitable for medium and high viscosity substances.
The most frequent causes of malfunction and the corrective actions to check before contacting technical support.
Learn more: the pump does not prime and does not dose →Start the pump with the stroke length set to 20% and minimum back pressure; after about 5 minutes increase it gradually. If the pressure exceeds the rated value, stop the motor immediately.
Check the level using the dedicated indicator and never run the pump without oil; change it every 8,000 – 10,000 operating hours and in any case at least once a year.
Every three months check bolts and seals; once a year check that flow rate, pressure and power match the rating plate data. With abrasive or corrosive chemicals, shorten the intervals.
If the problem persists, contact us. Before sending the pump for servicing, empty the pump head of chemical and dry it.
The knob reduces the stroke length of the diaphragm, i.e. the volume of each injection and, consequently, the maximum flow rate. This offers two advantages:
Linear dosing: a high number of small-volume injections promotes mixing of the chemical into the water flow and avoids concentration peaks.
Accuracy at low dosing rates: with a 10 l/h pump required to dose 1 l/h, reducing the stroke length to 50% brings the maximum flow rate down to 5 l/h and doubles the injection frequency. Particularly suitable in combination with the pulse-output water meter.
Horizontal installation, or vertical installation by means of a dedicated bracket.
Tell us about your application: our technical staff will recommend the most suitable model, configuration and accessories.